【文章內(nèi)容簡介】
luding Fire isolated stairways, ramps and passage ways including handrails, balustrades and stair treads Clauses , , to , , , Three monthly inspections to ensure there are no obstructions and no alterations have been made. Smoke lobbies in fireisolated exits , Annual inspection to ensure there are no obstructions and no alterations have been made. Clause Safety Measures Measures to be maintained BCA provisions for determining standard of performance Nature and frequency of maintenance Table Means of egress Open access ramps or balconies for fire isolated exits to D Annual inspection to ensure there are no obstructions and no alterations have been made. Doors (other than fire or smoke doors) in a required exit, forming part of a required exit or in a path of travel to a required exit, and associated self closing, automatic closing and latching mechanisms Clause , to , Three monthly inspections to ensure that the latches are operable and will open without the use of a key in an emergency. Measures to be maintained BCA provisions for determining standard of performance Nature and frequency of maintenance Table Signs Exit signs (including directional signs) Clauses , and and AS/NZS Six monthly inspections to confirm operation, avoidance of obstruction. Undertake procedures as prescribed in AS/NZS (previously 6 monthly) Signs concerning use of lifts in the event of fire Clause Annual inspections to ensure that the warning sign is in place and legible. Warning signs and alarms on sliding fire doors and doors to nonrequired stairways, ramps escalators Clause Annual inspection to confirm operation, avoidance of obstruction and that signs are in place and legible. For flashing luminaries and visual alarms, undertake procedures as prescribed in AS/NZS . Clause Safety Measures Clause Safety Measures Measures to be maintained BCA provisions for determining standard of performance Nature and frequency of maintenance Table Signs Signs, intermunication systems, or alarm systems on doors of fireisolated exits stating that reentry to a storey is available Clause Annual inspection to ensure signs are in place and legible Signs alerting people that operation of doors must not be impaired Clause Annual inspection to ensure signs are in place and legible Signs required on doors in alpine areas, alerting people that they open inwards Clause Annual inspection to ensure signs are in place and legible Fire order signs required in alpine areas. Clause G Annual inspection to ensure signs are in place and legible. Clause Safety Measures Measures to be maintained BCA provisions for determining standard of performance Nature and frequency of maintenance Table Emergency lighting Emergency lighting Clauses and , and AS/NZS Three/six monthly visual inspections to ensure operation, power availability and avoidance from obstruction. Undertake procedures as prescribed in AS/NZS . 2 (previously 6 monthly) Artificial lighting required to assist occupant movement and egress Clauses , ,and AS Three monthly inspections to ensure lighting levels are still achieved and not affected by obstructions. Clause Safety Measures Measures to be maintained BCA provisions for determining standard of performance Nature and frequency of maintenance Table Firefighting service and equipment Fire control centres (or rooms) Specification Annual inspection to ensure pliance of construction and contents with BCA. Special hazards firefighting systems and equipment Clause As prescribed in AS or AS as applicable. Table Airhandling systems Smoke hazard management: systems Clause Automatic smoke exhaust system Specification or as approved by the relevant authority As prescribed in AS . Frequencies modified for Level 1 – 6 monthly Automatic smoke and heat vents Specification or as approved by the relevant authority As prescribed in AS . Frequencies modified for Level 1 – 6 monthly Clause Safety Measures Measures to be maintained BCA provisions for determining standard of performance Nature and frequency of maintenance Table Airhandling systems Air handling systems that do not form part of smoke hazard management system and which may unduly contribute to the spread of smoke Specifications and and AS 2665 As prescribed in AS Miscellaneous air handling systems covered by Sections 5 11 of AS serving more than 1 fire partment Specifications and as applicable, or