uter room will be logged. The logs will be reviewed by IT manager on a regular basis with unauthorized access attempts being investigated. Logs should be kept for a minimum of three months unless otherwise restricted by law. 任何人進入電腦機房都必須在 “電腦機房進出人員登記表 ”上簽字。所有對電腦機房的使用都將被記錄。記錄將會被 IT經(jīng)理定期檢查是否有未授權(quán)的使用企圖。記錄 必須至少保持三個月或者遵從相關(guān)的法律規(guī)定。 4) All doors to the areas are to be kept locked at all times even during normal office hours. 所有電腦機房區(qū)域的門都應(yīng)始終保持鎖閉狀態(tài),即使是在上班時間也一樣。 5) Keys to the puter room areas will only be issued to personnel responsible. 電腦機房的鑰匙只能發(fā)放給相關(guān)的責任人員。 6) The Information System area must be regularly patrolled by hotel security staff. 酒店保安部員工應(yīng)對技術(shù)信息部區(qū)域進行周期性的巡邏。 8 IHG Greater China IT Standard Operating Procedure IT Routines Lists Department: Pamp。P: Information BEST PRACTICES Hotel logo Technology Subject: Date: IT Routines Lists Prepared by: Approved by: ____________ ______________________ ___________________ name of IT Manager name of GM name of FC IT Manager General Manager Dir of Finance amp。 Business Supporthotel name Distribution List: Daily Check List 每日檢查清單 IT Department must have a DAILY TASK LIST of what is needed to be checked and monitored. The checklist consists of what are needed to be done upon reaching office and before you leave office. The check list should include of all servers, systems, interfaces and work equipments to ensure all IT Systems are in goodworking condition. IT部門必須使用每日任務(wù)列表來記錄日常的檢查和監(jiān)測。該清單由到達 IT辦公室和離開之前需 要完成的檢查和檢測,包括服務(wù)器、系統(tǒng)、接口和網(wǎng)絡(luò)設(shè)備,以確保所有的 IT系統(tǒng)處于良好工作狀態(tài)。 IT Office and Server room checks IT辦公室和服務(wù)器機房檢查 : a. Make sure the IT Server Room AirConditioning System is running and maintain temperature at a range of 20 degrees Celsius to 22 degrees Celsius, humidity at a range of 50RH to 60RH. If temperature or humidity is out of this range, go to the Power Control Unit (PCU) and perform diagnostics and check ALARM History and do a RESET. If found malfunctioning, call the Engineering for further assistance. 確保機 房空調(diào)工作正常,機房溫度應(yīng)維持在在 2022攝氏度之間,濕度在 5060RH之間。如果發(fā)現(xiàn)溫度或濕度不在標準范圍,請檢測電力控制裝置和警示燈,并且重新啟動。如果發(fā)現(xiàn)故障,通知工程部做進一步檢查。 b. Make sure the IT Server Room main UPS is up and running on normal. Check that the charging level is 100%. 確保服務(wù)器機房主 UPS 啟動和運行正常,并且電池電量為 100%。 c. Make sure the LOCKS of IT office and server room work properly. 確保 IT辦公室和服務(wù)器機房的門鎖工作正常。 9 IHG Greater China IT Standard Operating Procedure d. Remove any obstructions, unnecessary or faulty devices on the floor of the IT Office at all times. IT辦公室不能在地板上放置任何障礙物和不需要或者失效的設(shè)備。 IT SERVERS Checks 服務(wù)器檢查 : a. Check all the SERVERS and system logs, make sure all servers are up and running. 檢查所有服務(wù)器和系統(tǒng)日志,確保所有服務(wù)器啟動和工作正常。 b. Check ALL INTERFACE PCs, make sure all the interfaces are up and running. 檢查所有的接口電腦,確保所有的接口都啟動和工作正常。 c. Check the inter is working and server is sending and receiving mails and there are no messages on long queue to be delivered. 檢查互聯(lián)網(wǎng)訪問正常;電子郵件服務(wù)器發(fā)送和接收電子郵件正常,并沒有長時間不能發(fā)出的郵件。 d. Check the PRINTSERVER for any problem on the printer queuing of all Departments. 檢查所有部門的打印服務(wù)器工作正常。 e. Check the AntiVirus Server and make sure it updates itself to the latest VIRUS DEFINITIONS and SCAN ENGINE. Run the Antivirus report to list down all the potential users with viruses and Trojans. 檢查防病毒服務(wù)器有最新的病毒定義庫和病毒掃描引擎。檢查防病毒報告中用戶潛在的病毒和木馬程序。 f. Check the FAX Server and the modems if are active and ready. 檢查傳真服務(wù)器和調(diào)制解調(diào)器工作正常。 g. Check the FILE Servers for HARDDISK Space. If found running out of space, do an investigation on user folders. 檢 查文件服務(wù)器磁盤空間。如果發(fā)現(xiàn)空間不足,對用戶空間進行分析處理。 h. Check all other servers, to record available diskspace. 檢查所有服務(wù)器,記錄硬盤空間。 i. Check two workstations at random to ensure that they are getting the latest updated virus definition from internal server or inter (Please Check the definition updated date) 隨機抽測兩臺工作站,確??梢詮幕ヂ?lián)網(wǎng)或者內(nèi)部網(wǎng)絡(luò)獲得最新的病毒定義(請檢查病毒定義庫更新時間)。 Check Backup Status 備份檢查 : a. Check the BACKUP Server for the COMPLETION of all JOB Orders and to check 10 IHG Greater China IT Standard Operating Procedure any FAILED JOBS. Replace BACKUP TAPE or other BACKUP MEDIA. 檢查備份服務(wù)器確保所有的備份完成。檢查的備份任務(wù)。更換備份磁帶或備份介質(zhì)。 IT NETWORKS Checks 網(wǎng)絡(luò)檢查 : a. Check Holidex router is up and running and IHG work is accessible. By accessing the Holidex system at and checking OXI processor in PMS. 通過訪問 Holidex系統(tǒng) 并檢查 PMS系統(tǒng)中的 OXI進程來確認 Holidex路由器是否啟動和工作正常, IHG網(wǎng)絡(luò)可以正常訪問。 b. Analyze unknown devices connected to the local work. 分 析連接在內(nèi)部網(wǎng)絡(luò)上的未知設(shè)備。 c. Check the local ISP Router Traffic Grapher or HSIA system to see the bandwidth utilization of the inter in the guest rooms and the admin office inter. 通過本地 ISP的路由流量記錄器或者 HSIA系統(tǒng)檢查辦公網(wǎng)絡(luò)和客房網(wǎng)絡(luò)的帶寬使用率。 d. Check Firewall logs for any attempts to break into the work. 檢查防火墻日志是否有網(wǎng)絡(luò)安全攻擊。 e. Check the pattern of work switch lights to ensure no switch hangs or looping detected. 檢查網(wǎng)絡(luò)交換機指示燈確保沒有交換機故障。 USER AND GUEST SERVICE Checks 用戶和客人服務(wù)檢查 : a. Check both guest and hotel user call log registers. 檢查所有用戶和客人要求記錄。 b. Communicate and share problems among hotel IT team. 與整個酒店 IT團隊溝通并且分享問題。 c. Escalate the calls to PMS, POS, other support vendors and regional IT team if it could not resolve internally as soon as necessary. 將不能內(nèi)部解決的問題立刻反饋至 PMS, POS等供應(yīng)商和集團 IT團隊。 d. Keep in touch with regional IT team if you are in doubt or undecided and ask for help and assistance. 如有任何疑問,請與集團 IT團隊聯(lián)系。 Weekly Task 每周任務(wù) Offsite Backup Tape 外部保存?zhèn)浞荽艓? Send one backup tape set outside the hotel. Before sending out, do a restore test 11 IHG Greater China IT Standard Operating Procedure (Restore data to a spare hard disk to ensure it can be restored successfully). 每周將一份備份磁帶送至酒店外部保存。在送出前,做一個簡單恢復(fù)測試 (即將磁帶內(nèi)容恢復(fù)到某個服務(wù)器的空余硬盤上保證磁帶數(shù)據(jù)可以 被成功讀出 )。 Monthly Task 每月任務(wù) Backup befo