【正文】
rect wall mounting shall be so constructed so that there is no cracking or breaking or damage to the mounting bracket, its securing means and the portion of the shelf attached to it when each supporting surface is both individually and simultaneously loaded with four times the load specified in table for one minute 27. Appurtenance Loading Test (TipOver Resistance) For units over 30 Inch height, apply a 50 Lb downward force for 1 minute to any portion of the unit within 30 inches of the floor that is likely to support part or all of a child’s weight. There shall be no tipover of the unit 28. Impact Test – Glass Parts Structural glass parts shall ply with the requirements in the impact test, section 19. A decorative glass part having an area greater than 1 Ft2 or having a minor dimension greater than 18 inches, shall not be broken, shattered (totally or in part), or displaced when tested as described in of this section. 29. Impact Durability (B) for units under 30 inches high No structural breakage when 200 Lbs. test load falls free from 6 In. to the center of the top with no static load in the other half of the top 30. Front Seating Capability (For Floor Standing Units Under 30 Inch Height And Flat Horizontal Top Surface Which May Be Sat On) No failure under 300 Lbs loading at 6 inches at edge (6 inches) 31. Drawer Operability After distributed loading of 10 Lbs. / drawer, max. 10 Lbs. pull force 32. Racking Test No structural damage or deformation when the unit is raised 45176。 or c) The maximum intended load for a dedicated storage area intended to acmodate a specific accessory. Each supporting surface shall be tested for one minute with the other supporting surfaces unloaded. 22. Finger Entrapment Shall meet the requirements intended to eliminate the possible hazard that may be caused by changing clearances or permanent entrapment and pinching of fixed openings.(5mm or 13mm) 23. Loading Test Individual Loading (Flat Panel TV Stand ) A cart or stand shall be constructed so that there is no collapse or permanent damage that results in risk of injury to persons when each supporting surface it individually loaded with: a) 200 pounds for flat panel TV rack。 with the horizontal with a simulated load per table attached to the flat panel TV rack. 21. Loading Test – Individual Loading (Conventional TV Stand ) A cart or stand shall be constructed so that there is no collapse or permanent damage that results in risk of injury to persons when each supporting surface it individually loaded with: a) Two times the load specified in table plus 100 pounds for the surface intended to support a television。 100176。 F And 140176。 inches deformation when load is applied to a 12 inches diameter disk located such that the center of the disk is 6 inches from the edge of the top surface Top Surface Area 4 sq ft – 300 lbs/ 4 sq ft – 200 lbs 29. Stability (For Units Over 42 inches Height) No tipover should occur under the following conditions Horizontal force of 40 lbs or an angle 10 deg before tipping occur 30. Stability (For Floor Standing Units Up to 42 Inches Height) No tip over should occur under the following conditions Must not have any one leg lift off the floor when test load is applied 1 inches from the edge of 12 inches disk 4 sq ft – 100 lbs/4 sq ft 90 lbs 31. Racking Test No structural damage or deformation when the unit is raised 45 degrees from the floor 32. Leg Strength (Side/Front) 75 lbs (40 lbs if Unit is less than 30 inches height) applied vertically to the leg at 1inch from the end of the leg. Force is applied in 4 directions (Forward/rearward, side to side). No failure/permanent deformation 33. Impact Durability No structural breakage when 200 lbs test load falls 6 inches to the center of the top. Loading Test (TipOver Resistance) For units over 30 Inch height, apply a 50 lb downward force for 1 minute to any portion of the unit within 30 inches of the floor that is likely to support part or all of a child’s weight. There shall be no tipover of the unit 35. Drawer Operability Max 10 lbs pull force with distributed drawer load (30 lbs/cubic ft – 10 lbs minimum) 36. Extendible Shelves/Supports Max 10 lbs pull force with distributed load (per table 1a, see last page of protocol) 37. Lightfastness (Indoor Use –For Hard Materials Only) Class 20 hrs Test up to 5 major/main ponents MTL/ SGS TEST LIST (3) (Home Entertainment Center / TV Stand (UL 1678 4th Ed.) Quality test standard/method Criteria Results / Design/Features The actuality must keep consistency with the claim. Shall be included if necessary. Shall include assembly, mounting, use, maintenance, cleaning and safety information as required in the language(s) applicable to the destination country(s) with no errors or spelling mistakes. Shall be easy to follow and accurate. size/weight Report actual. Shall ply with any claims (0%, +3%) 4. Costco Plastic Bag Warning Statement If plastic bags (of any thickness) with a perimeter of 14 inches or greater are used in inner packaging, the following warning statement must be printed on at least one side of each bag in English, French and Spanish: 5. Lead In Surface Coating Shall not exceed 600 ppm (% by weight) total lead 6. Workmanship/ Level ? No major defects ? No ponents missing, malformed or fractured ? No hardware missing ? Smoothly ground welds, not overground and free of pits and splatter ? No burrs ? No loose ponents and unsecured fastening where rigidity is required ? In the case of wood (. laminates) proper and uniform adhesion ? No scratches, dents, cracks, marred or discolored surface ? In the case of molded plastic, consisten