freepeople性欧美熟妇, 色戒完整版无删减158分钟hd, 无码精品国产vα在线观看DVD, 丰满少妇伦精品无码专区在线观看,艾栗栗与纹身男宾馆3p50分钟,国产AV片在线观看,黑人与美女高潮,18岁女RAPPERDISSSUBS,国产手机在机看影片

正文內(nèi)容

英文_布勒機(jī)械施工組織設(shè)計(jì)五冶金建-資料下載頁(yè)

2025-06-01 21:11本頁(yè)面

【導(dǎo)讀】Construction,Organization&Design. MachineryPlant. QuotationProposal. WuxiSubsidiary. Content. difficulties. I.Projecttarget. 5.Mark. III.Earthworks. V.Steelstructure. VI.Groundworks. B.Roadconstruction. 1.Roadconstruction. 1.Qualitytarget. IV.Controlofnon-conformityproducts. I.On-siteRegulations. VII.WorkingatNight. 1.Proposalscope. drawings.Generalinformation. September26th20xx,

  

【正文】 w of drawings. 2. Compile the construction scheme, map out the process flow and write down the technical draft. 3. Compile the construction budget. According to the quotation sheet and engineering budget, bining with the construction anization design and construction technology, take advantage of data information to pile the construction budget matching up to the practical construction. 4. Duplicate the sample, work out the processing plan for material, tools and semifinished product referring to all professional job drawings. 5. Compile the work plan in stages according to the overall scheduling. 6. Work out the pertinent technical quality requirements and management criterion in accordance with the requirements of consistent standard. II. Outfield preparation 1. Make the inspection and assay for raw material and trialproportioning for concrete and mortar. 2. Make the control survey point and main guide pile, or make the building orientation if condition permits. 3. Survey the bench mark, plete the impermanent bench mark and enclosure well. 4. Level up the field, build and repair the temporary fences used for construction. 5. According to the construction plan, lay the upanddown water pipe, dig the sedimentation basin, place the temporary road, plan and harden the construction site, set up the vehicle washing trough. 6. Set up the temporary facilities, switch on the power supply from distribution room to each application point. IV. Construction layout I. overall layout design According to the scheduling of construction site, carry out the dynamic control of subcontracting to construction overall layout under the instruction of general contracting, plete the zoning scheme in stages and in majors, make the pact collective management relatively independent. Based on creating the demonstration project of civilized construction, try to build the genuine gardenstyle construction site, produce a good trademark image for all sides that participate the construction. II. Layout of temporary facilities Roads in construction site are mainly as per the existing road system. Outfield road is mainly dominated by Xuedian Road. 1. Office buildings: (1) Office buildings for owner, supervisor and general contracting site adopt the temporary camp house made by color steel plate of one storey. ( as shown in figure) (2) Office buildings for construction are planned to be close to the above office buildings, setting up the unified camp house made by color steel plate of one storey with size of each. 2. Living quarters (1) Dorm: outside the construction site (2) Toilet: set up two waterflush toilets of size at one side of dorm, and two cesspools of 4m3m size outside the toilet. The discharged sewerage shall be put through the drain outlet pipeline on construction site and somebody is specially assigned to be in charge of the cleaning. (3) Canteen: outside the construction site, send for lunch. 3. Guard: set up two guard rooms, the guards shall be in charge of security defense and fire fighting for all persons on construction site and inandout materials. 4. Vehicle washing stand: in order to ensure the cleanliness of whole concrete vehicle when placing and grinding the concrete, and avoid the ―cast, splash, drop, leak‖ affecting the cleanliness of urban roads, on the arterial road of construction at the northern side of major entrance and exit set up vehicle washing stand and impounding reservoir for washing the vehicle before its going out, all sewerage disposed through settlement discharge into the drainage work on site. III. Temporary electricity layout for construction According to the requirements of this project, on site set up one distribution room of 500KVA. In order to ensure the normal power supply for producing area and safe utilization of electricity for living quarters, temporary utilization of electricity for construction is separately laid in the plan, thus independent power transmission system is respectively formed in office area, living quarter and producing area for construction. 1. Electricity layout in construction area According to the power equipment layout on construction site, in order to realize the equal utilization of electricity, this project will lay the cable by three lines, one line is switched from the power supply to temporary facilities, another line is for water supply and road, and the last line is for living. 2. All cables are laid along the site road and buried underneath the ground 40cm, filling up sand covered with one layer fireclay brick. The specification of cable is 325㎡ ,equipped with at least five general distribution boxes. all nodes of electricity for construction are switched from general distribution boxes, which are fixed with support abutment. IV. Temporary water supply and drainage system layout for construction 1. Temporary water supply layout for construction (1) Water inlet manifold is supplied to the construction site by owner. Considering the large occupying area and dispersed water consumption point of this project, plan to set up one sag sink at the main inlet, adopt one booster pump for water supply. Onsite internal manifold adopts water pipe of φ100, all branch pipes are of φ50. (2) Except the taps set in water consumption points for construction and living, all other points are planned to set up the taps ofφ20 around. 2. Layout of drainage system The drainage system of whole site is through the main drain, after several settlement, then discharge into the urban sewer. V. Mark: On the entrance and exit road going to the office area, hang four plates one drawing for construction, and safety alarm plate in the safety alarm position。 popularization mark about owner and contractor hung on the building and fences.
點(diǎn)擊復(fù)制文檔內(nèi)容
研究報(bào)告相關(guān)推薦
文庫(kù)吧 www.dybbs8.com
備案圖鄂ICP備17016276號(hào)-1