【正文】 HASE IOC2 BLOCK B:"OFF"PHASE IOC2 BLOCK C:"OFF"PHASE IOC2 TARGET:"LATCHED"PHASE IOC2 EVENTS:"Enabled"PHASE TOC1 FUNCTION:"Enabled"PHASE TOC1 SOURCE:"SRC1"PHASE TOC1 INPUT:"Phasor"PHASE TOC1 PICKUP:" pu"PHASE TOC1 CURVE:"IEEE Ext Inv"PHASE TOC1 TD MULTIPLIER:""PHASE TOC1 RESET:"Instantaneous"PHASE TOC1 VOLTAGE RESTRAINT:"Disabled"PHASE TOC1 BLOCK A:"OFF"PHASE TOC1 BLOCK B:"OFF"PHASE TOC1 BLOCK C:"OFF"PHASE TOC1 TARGET:"Latched"PHASE TOC1 EVENTS:"Enabled"第二部分:發(fā)變組C、D柜保護整定計算1主變差動主變高壓側(cè)CT TA1 +TA17 2500/1 星形接線 T60—I 主變低壓側(cè)CT TA9 25000/5 星形接線 T60—I廠變高壓側(cè)CT TA42+TA55 2000/5 星形接線 T60—I 主變高壓側(cè)CT TA2 +TA18 2500/1 星形接線 T60—II 主變低壓側(cè)CT TA10 25000/5 星形接線 T60—II廠變高壓側(cè)CT TA41+TA54 2000/5 星形接線 T60—II 主變差動保護由雙斜率比例差動保護和差動速斷保護組成,做為變壓器內(nèi)部故障的主保護,主要反應(yīng)變壓器油箱內(nèi)部、套管和引出線的相間和接地短路故障,以及繞組的匝間短路故障。該保護動作于全停方式。、基本側(cè)的選擇、計算各繞組的額定電流Irated(1)= Irated(2)=Irated(3)=、計算各繞組CT的裕度Imargin(1)= Imargin(2)=Imargin(3)=、選擇CT裕度最小的繞組 Wrel=比例差動選T60中PERCENT DIFFERENTIAL為主變差動保護中的比例差動元件。動作特性如圖所示。 、最小動作電流(MINIMUM PICKUP)依據(jù)《導(dǎo)則》,最小動作電流應(yīng)大于變壓器額定負載時的不平衡電流,即式中:——可靠系數(shù), ~?!娏骰ジ衅鞯谋日`差,2;ΔU——變壓器調(diào)壓引起的誤差,取調(diào)壓范圍中偏離額定值的最大值(百分值)。取?!獎畲抛冸娏饕鸬牟黄胶獍俜直?。勵磁變低壓側(cè)最大短路電流為3087A(22kV側(cè)),占主變低壓側(cè)額定電流(18896A)%。Δm——CT變比未匹配產(chǎn)生的誤差,由于用軟件平衡,取0。在工程實用整定計算中可選取=(~)。即折算到基本側(cè) 式中:——平衡系數(shù)。表示為pu值為 取MINIMUM PICKUP= pu、斜率1(SLOPE1),斜率1應(yīng)大于非周期分量引起的CT誤差產(chǎn)生的不平衡電流。式中:——非周期分量系數(shù),~,;——電流互感器的同型系數(shù),Kcc=;——電流互感器的比誤差。又依據(jù)《導(dǎo)則》,~,差動保護不必具有制動特性。取 SLOPE1=30%、拐點1(BREAK1),拐點1應(yīng)小于由于直流分量和剩磁引起CT飽和的電流值。為使變壓器繞組內(nèi)部故障獲得較高的靈敏度,~3倍變壓器額定電流時,制動量不要增加太快。即 取BREAK1= pu、拐點2(BREAK2),拐點2是第二斜率的起點,應(yīng)小于僅由交流分量引起CT飽和的電流值。因保護用CT為5P20,20倍額定電流時誤差不超過5%,而變壓器高壓側(cè)區(qū)外短路時,()倍,為使繞組內(nèi)部短路獲得較高的靈敏度,區(qū)外故障有足夠的制動電流,因此取5倍變壓器額定電流為拐點2對應(yīng)的電流值。即 取 BREAK2= pu、斜率2(SLOPE2),斜率2應(yīng)大于最嚴重外部故障(即一側(cè)CT飽和,另一側(cè)未飽和)情況下產(chǎn)生的斜率,此值可高達95%~98%。考慮電廠實際情況,遠未達到CT飽和區(qū),因此依據(jù)《導(dǎo)則》考慮與第一斜率配合,第二斜率取60%。即 SLOPE2=60%、靈敏度校驗、主變高壓側(cè)區(qū)內(nèi)兩相金屬性短路 從短路電流計算書中可知,最小運行方式下發(fā)電機提供的短路電流A,系統(tǒng)側(cè)提供的短路電流A。 或 或 ,在動作特性曲線上查得對應(yīng)的動作電流= pu,則靈敏系數(shù)為:、主變低壓側(cè)區(qū)內(nèi)兩相金屬性短路從短路電流計算書中可知,最小運行方式下發(fā)電機提供的短路電流A,系統(tǒng)側(cè)提供的短路電流A。 或 或 ,在動作特性曲線上查得對應(yīng)的動作電流= pu,則靈敏系數(shù)為:、二次諧波制動比(INRUSH INHIBIT LEVEL)根據(jù)經(jīng)驗,二次諧波制動比整定為15%~20%。此值應(yīng)以制造廠提供的數(shù)據(jù)為準(zhǔn),用戶按空載合閘不誤動進行檢驗。取 INRUSH INHIBIT LEVEL=15%、過激磁制動比(OVEREXITATION INHIBIT LEVEL)根據(jù)經(jīng)驗,五次諧波制動比整定為30%。取 OVEREXITATION INHIBIT LEVEL=30%、差動速斷 選T60中Instantaneous Differential為主變差動保護中的差動速斷元件。差動速斷是變壓器高壓側(cè)引出線故障的快速保護,則應(yīng)裝設(shè)差速斷保護。、差速斷動作值依據(jù)《導(dǎo)則》,差動速斷的整定值應(yīng)按躲過變壓器初始勵磁涌流或外部短路最大不平衡電流整定。由于主變與發(fā)電機之間設(shè)斷開點,因此主變有空載合閘方式,取變壓器勵磁涌流為3倍變壓器額定電流。兩繞組變壓器外部短路最大不平衡電流動作電流 綜合考慮后,取PICKUP= pu、靈敏度校驗、按變壓器高壓側(cè)二相短路校驗最小動作電流 靈敏系數(shù) 、按變壓器低壓側(cè)二相短路校驗最小動作電流 靈敏系數(shù) 、定值清單、TRANSFORMERGENERALNUMBER OF WINDINGS:"2"PHASE COMPENSATION:"Internal(software)"LOAD LOSS AT RATED LOAD:"1064kw"RATED WINDING TEMP RISE:"65℃(oil)"NO LOAD LOSS:"338kw"TYPE OF COOLING:"ODAF"TOPOIL RISE OVER:"55℃"THERMAL CAPACITY:"100kwh/℃"WINDING THERMAL TIME:""WINDING 1WINDING 1 SOURCE:"SRC1"頁:39是否應(yīng)設(shè)置為SRC1=M1+M5 ;SRC2=F1+F5WINDING 1 RATED MVA:" MVA"WINDING 1 NOM φ-φ VOLTAGE:" kV"WINDING 1 CONNECTION:"Wye"WINDING 1 GROUNDING:"Within zone"WINDING 1 ANGLE WRT WINDING 1:"176。"WINDING 1 RESISTANCE 3φ:""WINDING 2WINDING 2 SOURCE:"SRC2"WINDING 2 RATED MVA:" MVA"WINDING 2 NOM φ-φ VOLTAGE:" kV"WINDING 2 CONNECTION:"Delta"WINDING 2 GROUNDING:"Not within zone"WINDING 2 ANGLE WRT WINDING 1:"176。"WINDING 2 RESISTANCE 3φ:""、PERCENT DIFFERENTPERCENT DIFFERENTIAL FUNCTION:"Enabled"PERCENT DIFFERENTIAL PICKUP:" pu"PERCENT DIFFERENTIAL SLOPE 1:"30%"PERCENT DIFFERENTIAL BREAK 1:" pu"PERCENT DIFFERENTIAL BREAK 2:" pu"PERCENT DIFFERENTIAL SLOPE 2:"60%"INRUSH INHIBIT FUNCTION:"Adapt. 2nd"INRUSH INHIBIT MODE:"Per phase"INRUSH INHIBIT LEVEL:"% f0"OVEREXCITION INHIBIT FUNCTION:"5th"OVEREXCITION INHIBIT LEVEL:"30% f0"PERCENT DIFF BLOCK:"OFF"PERCENT DIFFERENTIAL TARGET:"Latched"PERCENT DIFFERENTIAL EVENTS:"Enabled"、INSTANTANEOUS DIFFERENTIALINST DIFFERENTIAL FUNCTION:"Enabled"INST DIFFERENTIAL PICKUP:" pu"INST DIFF BLOCK:"OFF"INST DIFFERENTIAL TARGET:"Latched"INST DIFFERENTIAL EVENTS:"Enabled"1主變復(fù)合電壓過流主變低壓側(cè)PT 4YH T60—I T60—II主變高壓側(cè)CT TA1+TA17 2500/5 星形接線 T60—I 主變高壓側(cè)CT TA2+TA18 2500/5 星形接線 T60—II 復(fù)合電壓由廠高變A 的T60引出。選廠高變A的T60中PHASE UV1作為主變低電壓元件;選廠高變A的T60中的FLEXELEMENTS 1作為主變負序電壓;選主變T60中的PHASE IOC1為主變過電流元件。選主變T60中TIME1為時間元件。保護動作于全停。 根據(jù)《導(dǎo)則》,過電流元件按躲過主變額定電流整定;低電壓元件按躲過主變低壓側(cè)可能出現(xiàn)的最低電壓整定;負序過電壓元件按躲過正常運行時的不平衡電壓整定。11 主變過電流元件 折算至標(biāo)么值為:靈敏度校驗: 要求靈敏度≥式中:后備保護區(qū)末端金屬性二相短路時流過保護的最小短路電流。 12 主變低電壓元件靈敏度校驗:式中::計算運行方式下,靈敏度校驗點發(fā)生金屬性相間短路時,保護安裝處的最高殘壓。 13 主變負序電壓元件 靈敏度校驗:式中:——后備保護區(qū)末端二相金屬隆短路時,保護安裝處的最小負序電壓。14 動作時間:按大于線路后備保護的動作時間整定,動作于全停。15 定值清單PHASE IOC1 FUNCTION:"Enabled"PHASE IOC1 SOURCE:"SRC1"PHASE IOC1 PICKUP:"" PHASE IOC1 DELAY: "0S"PHASE IOC1 RESET:""PHASE IOC1 BLOCK A :"OFF"PHASE IOC1 BLOCK B:"OFF"PHASE IOC1 BLOCK C :"OFF"PHASE IOC1 TARGET:"Latched"PHASE IOC1 EVENTS:"EnabledPHASE UV1 FUNCTION:"Enabled"PHASE UV1 SOURCE:"SRC1"PHASE UV1 MODE:"PHASE TO PHASE"PHASE UV1 PICKUP:""PHASE UV1 CURVE: "DEFINITE TIME" PHASE UV1 DELAY: ""PHASE UV1 MINIUM VOLTAGE:""PHASE UV1 BLOCK :"OFF"頁:42是否要斷線閉鎖PHASE UV1 TARGET:"Latched"PHASE UV1 EVENTS:"Enabled"FLEXELEMENTS 1FUNCTION:"Enabled"NAME:"U2"INPUT PLUS:"SRC1 U_2 Mag"INPUT MINUS:"OFF"INPUT MODE:"SIGNED"COMPARE MODE:"LEVEL"DIRECTION TYPE:"OVER"PICKUP:""HYSTERESIS:"%"DELTATUNITS:"Milliseconds"DELTAT:"20"PICKUP DELAY:""RESET DELAY:""BLOCK:"OFF"TARGET:"Latched"EVENTS:"Enabled"TIMER1:TYPE:"Second"PICKUP DELAY:""DROPOUT DELAY:"" 主變零序過流保護 主變高壓側(cè)零序CT 1LLH 30
點擊復(fù)制文檔內(nèi)容
環(huán)評公示相關(guān)推薦
文庫吧 www.dybbs8.com
備案圖鄂ICP備17016276號-1