【正文】
midity less than 95%月平均相對(duì)濕度 90%及以下Monthly average relative humidity less than 90%安裝場(chǎng)所的海拔高度 1000m及以下Height above sea level at site less than 1000m地震烈度: 不超過8度Earthquake intensity: less than 8 degree沒有火災(zāi)、爆炸危險(xiǎn),沒有嚴(yán)重污穢及化學(xué)腐蝕的場(chǎng)所。This product should not be used under conditions of fire, explosion,earthquake and chemical corrosion environments.Special service conditions對(duì)特殊工作條件,必須向制造廠咨詢。制造廠與用戶應(yīng)就特殊工作條件取得一致意見。The manufacture must be consulted in advance about each special service condition. Special service conditions are to be agreed on by the manufacturer and user. l 已考慮安裝場(chǎng)所的海拔高于1000m時(shí),空氣介質(zhì)強(qiáng)度的降低對(duì)絕緣水平的影響。Allow for the reduction in the dielectric strength of the air when site altitude is over 1000ml 若環(huán)境溫度超出極限值,在母線和分支母線的設(shè)計(jì)上加以補(bǔ)償或限制載流量。在柜內(nèi)安裝通風(fēng)裝置將有利于開關(guān)柜的散熱。If the ambient temperature is over top of the highpoint, must consider equalizing or limiting current capacity for the design of main bus bar and branching bus bar. Installation the aerator is favor of rejection of heat. 注意事項(xiàng):Matters need attention:若開關(guān)柜運(yùn)行地區(qū)的濕度較高,溫度波動(dòng)速度較快且幅度較大,開關(guān)柜在這種氣候環(huán)境下運(yùn)行,就有凝露的危險(xiǎn),因此開關(guān)柜在備用和運(yùn)行狀態(tài)下,用戶應(yīng)保證加熱器全天侯投入!但在大電流運(yùn)行中,可以不投入。If the humidity is higher on site, temperature fluctuations speed is rapidder and range is bigger, condensation phenomena will be appear for the switchgears running in this clime condition, so user should ensure that the heater running full time on spare and running condition! But running in highcurrent, the heater can stop. 2技術(shù)數(shù)據(jù) Technical data 開關(guān)柜電氣參數(shù) Switchgear technical data額定電壓kV12額定絕緣水平1min工頻耐壓(有效值)kV42雷電沖擊耐壓(峰值)kV75額定頻率Hz50主母線額定電流A630,1250,1600,2000,2500,3150,4000分支母線額定電流A630,1250,1600,2000,2500,3150,4000*4秒熱穩(wěn)定電流(有效值)kA16,20,25,40**額定動(dòng)穩(wěn)定電流(峰值)***kA40,50,63,80,100Rated voltage kV12Rated powerfrequency withstand voltage(1min)kV42Rated lightening impulse withstand voltagekV75Rated frequencyHz50Rated main bus bar current A1600,1200,2500,3150,4000Rated branching bus bar currentA630,1250,1600,2000,2500,3150,4000*4s Shorttime withstand current(rms.)kA16,20,25,40Peak withstand current(peak.)kA40,50,63,80,100,125*需裝備通風(fēng)裝置 with forced ventilation.**40 kA為3秒 3 second for 40kA***儀用互感器的短路容量應(yīng)單獨(dú)考慮 The shortcircuit capability of transformer for measure should be considered by oneself. 耐內(nèi)部故障電弧性能 Performance bearing inside fault arcKYN2812開關(guān)柜在設(shè)計(jì)上已考慮到開關(guān)柜內(nèi)部故障電弧的問題,根據(jù)GB3906和IEC298進(jìn)行了嚴(yán)格的試驗(yàn),能有效地保證設(shè)備及操作人員的安全。KYN2812 has been considered with the problem of inside fault arc in switchgear on design. It is tested strictly according to GB3906 and IEC298, thus ensure effectively the safety of equipments and operation personnel. Outline dimensions and weight 外形尺寸 Outline dimensions高度a (mm) 2200寬度b (mm)分支母線額定電流為1250A及以下, 800/650*分支母線額定電流為1600A及以下,短路開斷電流為40kA 800分支母線額定電流為1600A及以上 1000深度c (mm) 1350/1500Height a 2200(mm) Width b Rated branching bus bar current up to 1250A,Rated shortcircuit breaking current(rms.) up to 800/650*(mm)Rated branching bus bar current up to 1600A,Rated shortcircuit breaking current(rms.) up to 40KA 800 (mm)Rated branching bus bar current over 1600A, 1000(mm)Depth c 1350/1500 (mm) 重量800~1200kg,詳細(xì)資料見表1。*配VD4斷路器可用。Weight 800~1200kg,for table 1showing.*Suitable for VD4 being equipped.表1 安裝要求的尺寸及柜體重量柜內(nèi)設(shè)備型式移開式移開式移開式柜深 c柜寬 b距墻距離mmmmmm150065080015008001000150010001200走廊寬度*mm100011001200安裝通道(室內(nèi)通道要求)寬度長(zhǎng)度(深)門框要求寬度高度mmmmmmmm10001500800220010001500100022001200150012002200重量(近似值)地坪承重kgkg/m28001000850100012001000List 1 Dimension and weight for switchgear installationMode of devicein switchgearRemovingtypeRemovingtypeRemovingtypedepth cWidth bDistance to wallmmmmmm1500650501500800501500100050The width of Passage *mm100011001200Assemble walkwayDemand of passage indoorWidthLength(Depth)Demands of door frameWidthHeight**mmmmmmmm10001500800200010001500100022001200150012002200Mass(approximation)Weight terrace bearedkgkg/m28001000850100012001000*取決于最大柜寬Depend on the most width of the switchgear.3 開關(guān)柜結(jié)構(gòu)概述Structure general of switchgear(圖3/1)Basic structure(Figure3/1)開關(guān)柜由固定的柜體和真空斷路器手車組成,這是它的基本結(jié)構(gòu)。開關(guān)柜及安裝的電氣元件見圖3/1。進(jìn)線柜或出線柜是基本柜方案,并有派生方案,如母線分段柜或計(jì)量柜等。此外,尚有配置固定式負(fù)荷開關(guān)、真空接觸器手車、隔離手車等方案。開關(guān)柜靠墻或面對(duì)面安裝。結(jié)構(gòu)細(xì)節(jié)和柜內(nèi)安裝設(shè)備,可見訂貨文件。The basic structure of switchgear panel prises the panel itself a removing part. The panel and main ponents can see in figure 3/ panel or outgoingline panel are diagram of basic switchgear panel,there are other derivative diagram,for example ,contact panel or metering panel .in addition,There are so many diagram of the switchgear panel with stationary type load switch、(SF6)VCB truck、VC truck、Disconnect truck. The panel has two maintenance modes. That is singleface maintenance and doubleface maintenance. The detail of structure and main ponents, can reference order document. Enclosure and clapboard開關(guān)柜的外殼和隔板由優(yōu)質(zhì)鋼板制成,具有很強(qiáng)的抗氧化、耐腐蝕功能,且剛度和機(jī)械強(qiáng)度比普通低碳鋼板高。三個(gè)高壓室的頂部都裝有壓力釋放板。出現(xiàn)內(nèi)部故障時(shí),高壓室內(nèi)氣壓升高,由于柜門已可靠密封,高壓氣體將沖開壓力釋放板釋放出來。相鄰的開關(guān)柜由各自的側(cè)板隔開,拼柜后仍有空氣緩