【正文】
by the personnel without authorization. The password must have 6 numbers with the “000000” as its original password. The system password refers to the programmable entering order of the extension。 in terms of the setting mode, to fill in the starting and end time in correspondence date with clicking on the Add Button to ensure the add operation, and the PBX has accepted such change, relevant information would be shown in the forms below. If there are no repeat data between the newly added information and the existed information, the system will memorize both messages. Click on the Clean Button, and all data on today’s onandoff work data will be cleaned off. Click on the Batch Processing Button at the bottom of the interface, it is able to realize the reset on the PBX in terms of the onandoff working time data from Monday to Sunday, or it enables to upload all data on onandoff working time to the puter so as to keep the data in the same. Time Period of Internal Calling:Time period setting on onandoff work and internal calling is different so as to avoid the unnecessary disturbance while the extension is in use. And it follows the same mode in setting. Economic Time Period:the system is in support of 8 economic routing, being from 0 to 7, with every route being consisted by several allowable dialing number. If the external dialing number also possesses the economic dialing entitlement, then the system will automatically add a routing code with highest priority in front of the dialing number (Refer to the setting of the economic routing). In terms of the orders of the economic routing allowable, it could be adjusted as required with the same setting interface and mode as that of the onandoff work time period setting, and the only difference existed is you are required to input the order from 0 to 7 if necessary. D、System Parameter:as required, the PBX is able to set some normal parameter。 it is a series of number added in front of the extension number, which has the same effect as direct dialing on the extension number. It has the same setting interface and methods of lockingup number at various levels. C. Time Period of System:system time period includes setting for onandoff time period, internal calling time period and economic time period。 if it is to delete certain number at certain grade, input the grade and the number required to be deleted in the text box, or to pitch on the number at corresponding grade, and then click on the delete Button. If the PBX has accepted the relevant change, the number deleted would disappear from the form timely. Batch processing follows the same way as that of the instant charging number. Public Number of Various Grades:Number of this kind refers to the number out of the grades of fixed extension number, but these numbers are allowed to be connected. Therefore, these numbers are not restricted by various grades and lockingup number. Grade 1 to grade 8 corresponds to the onandoff grade of various extensions, and the setting interface and mode are the same as that of lockingup number of various kinds. System Speed Dialing Number:it is able to set those frequently used number as the system speed dialing number so as to ease the client operation. Such kind of number has 10 groups in total with 0 to 9 in correspondence。 in terms of the setting mode, please choose corresponding grade, then input the number required to be locked at this grade, and click on the Add Button or press Enter。 Grade 1 to grade 8 corresponds to the onandoff grade of various extensions, and its locking up number is the prohibited dialing number at corresponding grades。 by doing so, the PBX could go on sending telephone list with different charging standard on these phone calls while the extension is dialing these numbers。 to delete the number, input or pitch on certain number and click on the Del Button, then you could see the number disappeared in the below form if the PBX accepts the change。 once the number is in connection, the system will begin charging on it. By doing so, it could improve the accuracy of charging, especially for those calling service platforms with short calling time. The setting interface is as above shown。 but if you alter on the port but no change on the baud rate, then the software would work normally after restarting. (Notice: change on baud rate just goes to the baud rate of puter maintenance software, and never goes to the PBX, then it is required to change the baud rate of the PBX so as to keep them in same.)To correctly display the status of the main interface, it is required to upload the flexible series number of extension, which enables the system to recognize the status of extension and trunk。 later on, the chosen color will bee the default color of the software. The original installation of the system must make relevant choice on the port setting and models with the upload of flexible series code to the maintenance software, otherwise, the software is unable to finish the task properly. Setting of Port:to choose the port setting of the system management, and fill in the original administrator password, which is the “000000”。 if the window is not large enough to show all big icons, then to show in the small icon is also allowed. If you want to see the detailed information on the telephones connected, then you could set the detailed list mode as the default mode。 once the telephone is in use, the corresponding icon will make relevant change with the display of telephone number under the icon (in both big icon mode and small icon mode). As illustrated, it means the extension 1033 and trunk 1081 is in connection,. 1033 is making phone calls with other telephone number with the adoption of 1081 trunk。 input logon name and password and then click the Yes Button, which leads to the turning on of the corresponding button. The operator is able to carry out the normal operation。 as followed, please