1000噸低溫冷庫(kù)設(shè)計(jì)計(jì)算說(shuō)明書畢業(yè)設(shè)計(jì)(存儲(chǔ)版)

  

【正文】 ? = kg/m3 供入庫(kù)房的計(jì)算流量 凍結(jié)間 1 設(shè)備冷負(fù)荷 冷風(fēng)機(jī)中氨液的流量 31 7 2 7 0 5 .7 8 1 0 0 .0 6 1 2 7 /1 2 1 8 .2 6oQM k g sq??? ? ? 凍結(jié)間 2 設(shè)備冷負(fù)荷 冷風(fēng)機(jī)中氨液的流量 31 7 2 7 0 5 .7 8 1 0 0 .0 6 1 2 7 /1 2 1 8 .2 6oQM k g sq??? ? ? 30 凍藏間 1 設(shè)備冷負(fù)荷 冷風(fēng)機(jī)中氨液的流量 31 2 9 5 2 . 5 4 1 03 0 . 0 1 5 0 5 /1 2 1 8 . 2 6M k g s???? 凍藏間 2 設(shè)備冷負(fù)荷 冷風(fēng)機(jī)中氨液的流量 31 1 3 5 9 . 8 5 1 0 0 . 0 1 3 7 4 /4 1 2 1 8 . 2 6M k g s???? 凍藏間 3 設(shè)備冷負(fù)荷 冷風(fēng)機(jī)中氨液的流量 31 2 9 5 2 . 5 4 1 05 0 . 0 1 5 0 5 /1 2 1 8 . 2 6M k g s???? 實(shí)際供入各庫(kù)房的氨液的體積流量分別為 通過(guò)公式?MV?求得 V1= m3/h V2=V5= m3/h 庫(kù)房回氣管道的實(shí)際流量 V1= m3/h V2= m3/h V3= m3/h V4= m3/h V5= m3/h 制冷系統(tǒng)的管道計(jì)算 管徑確定 計(jì)算管道內(nèi)徑 0 . 1 8 4 1 0 . 40 . 0 1 8 8 0 . 0 3 818nd?? ? ? 式中: nd管道內(nèi)徑 v計(jì)算狀態(tài)下制冷劑比容積( 3/m Kg ) mq制冷劑質(zhì)量流量( /kgh ) 制冷劑允許流速( /ms),由《冷庫(kù)設(shè)計(jì)》中表 6表 62 確定。 低壓循環(huán)桶的選擇計(jì)算 ddddddd nWVnW Vd ???? ? ??? 01 00 4 = d d低壓循環(huán)桶直徑( m); V低壓級(jí)壓縮機(jī)的理論輸氣量( m3/h) ; λ 低壓級(jí)壓縮機(jī)的輸氣系數(shù); W d低壓循環(huán)桶內(nèi)氣體流速,立式低桶不大于 ; ξ d截面積系數(shù),立式低壓循環(huán)桶ξ d=; n低壓循環(huán)桶氣體進(jìn)氣口的個(gè)數(shù),立式低壓循環(huán)桶為 1?!妫?]; △ 中間冷卻器蛇形管的對(duì)數(shù)平均溫度差( ℃ )。 h 各房間風(fēng)機(jī)風(fēng)量計(jì)算 : 房間 1 qv= =房間 2 qv= =房間 3 qv= =房間 4 qv= =房間 5 qv= = 冷風(fēng)機(jī)風(fēng)量的選型 根據(jù)《制冷空調(diào)產(chǎn)品設(shè)計(jì)手冊(cè)》 P400 及計(jì)算出的冷卻面積,風(fēng)量和射程選出個(gè)房間的冷風(fēng)機(jī)型號(hào)?!妫?];查表 417知排管換算系數(shù) 。 h),傳熱管用光鋼管,補(bǔ)充水量為循環(huán)水的 5%10%。 6. 選擇高壓級(jí)壓縮機(jī)。 系統(tǒng)采用循環(huán)水,由《冷藏庫(kù)設(shè)計(jì)》知,循環(huán)用水的水溫由當(dāng)?shù)厥彝饪諝獾臐袂驕囟榷ā? 電動(dòng)機(jī)運(yùn)轉(zhuǎn)熱流量計(jì)算表 電動(dòng)機(jī)運(yùn)轉(zhuǎn)負(fù)荷 Q=1000*Pd*b*£ 房間 風(fēng)機(jī)額定功率 Pd( KW) 熱轉(zhuǎn)化系數(shù)£ 電動(dòng)機(jī)運(yùn)轉(zhuǎn)時(shí)間系數(shù) b Q( W) 冷凍間 1 10 1 1 10000 冷凍間 2 10 1 1 10000 冷藏間 3 冷藏間 4 冷藏間 5 合計(jì) 20200 冷間操作熱流量 操作熱流量計(jì)算公式如下: ? ?rrnnwnkkdd nMhhVnnA ?????????? 1 ? 式中 Φ — 操作熱流量( W); Φ d— 每平方米照明熱流量,冷卻間、凍結(jié)間、冷藏間和冷間內(nèi)穿堂 可取 ㎡; nk— 每日開門換氣次數(shù); Vn— 冷間內(nèi)凈體積( m3); hw— 冷間外空氣的比焓( kJ/kg); hn— 冷間內(nèi)空氣的比焓( kJ/kg); M— 空氣幕效率修正系數(shù),可取 ; n? — 冷間內(nèi)空氣密度( kg/m3); 243 — 每日操作時(shí)間系數(shù),按每日操作 3小時(shí)計(jì)算; nr— 操作人員數(shù)量; Φ r— 每個(gè)操作人員產(chǎn)生的熱流量( W)冷間設(shè)計(jì)溫度高于或等與 5℃時(shí),宜取 279W;冷間設(shè)計(jì)溫度低于 5℃時(shí),宜取 395W。 2 樓板和內(nèi)墻長(zhǎng)、寬度應(yīng)自外墻內(nèi)表面至外墻內(nèi)表面或外墻內(nèi)表面至內(nèi)墻中或內(nèi)墻中至內(nèi)墻中計(jì)算?!?) 地帶 R 0 (㎡ 庫(kù)房地坪材料的選擇計(jì)算 地坪采用地下埋設(shè)自然通風(fēng)管道給地坪保溫。 查表知高溫側(cè)空氣的露點(diǎn)溫度為 t1=℃ 圍護(hù)結(jié)構(gòu)最小總熱阻: (㎡℃ /W) 370 ㎜厚磚砌墻 1 ?R=(㎡時(shí) 關(guān)鍵詞:壓縮 制冷 冷藏庫(kù) 節(jié)流 中間完全冷卻 Abstract T his design for the Zhangjiakou some 1000 ton low temperature cold storage design, was the production freezer storage, the cold storage has bee the facility which the essential food processing and stored for the daily life in, its system plex also used the working substance to be special, this design used the ammonia to take the working substance, as a result of its itself virose, the cold storage system safety production needed especially very much. The cold storage function is deepfreezes specially after the cold finishing meats, adjusts the pale prosperous season by the labor, guaranteed the market supplies, provide the foreign trade exportation and make using of the longterm store up. The pression type refrigeration is according to the refrigeration principle the pressor, the condenser, the throttle valve and the evaporator, as well as in order to cause the refrigeration potency to be higher, to move a safer supporting facility (for example 4 oil separator, liquid reservoir, gas fluid separator, circulation stock solution barrel, oil collector, puts air, pipe accessory, measuring appliance and so on) connects the position with the pipeline a closed refrigeration cycle. In the design process, to the refrigeration system each supporting facility shaping as well as in various storehouses refrigeration way choice has all made the optimized design from the refrigeration pressor choice, constructs the location according to the project the actual situation, the generalized analysis each refrigeration system in constructs under the location during detachment condition the feasible movement situation, finally in line with the economy, is detail drawingThe equipment base pilation. Keywords: Compression Freezer Throttle Complete cooling of the middle suitable, practical, the structure pact, the construction elegant appearance principle designs the chart, including refrigeration system schematic diagram, construction plan, equipment floorplan, engine room pipeline floorplan, storehouse pipeline floorplan, engine room sectional drawing, cold sectional drawing, pipeline equipment heat preservation chart, support detail drawing, condenser circulating water diagram, gas fluid regulating station 1 設(shè)計(jì)基本資料 設(shè)計(jì)目的: 畢業(yè)設(shè)計(jì)是工科類專業(yè)教學(xué)的重要環(huán)節(jié)之一,是對(duì)學(xué)生在校所學(xué)理論知識(shí)的全面總結(jié)和綜合檢驗(yàn)。在設(shè)計(jì)過(guò)程中,從制冷壓縮機(jī)的選擇 到制冷系統(tǒng)各輔助設(shè)備的選型以及各庫(kù)房制冷方式的選擇上都做了優(yōu)化設(shè)計(jì),根據(jù)項(xiàng)目建設(shè)場(chǎng)地的實(shí)際情況,綜合分析各制冷系統(tǒng)在建設(shè)場(chǎng)地客觀條件下的可行性運(yùn)行情況,最后本著經(jīng)濟(jì)、適用、實(shí)用、結(jié)構(gòu)緊湊、建筑美觀大方的原則設(shè)計(jì)出圖,包括制冷系統(tǒng)原理圖、建筑平面圖、設(shè)備平面布置圖、機(jī)房管道平面布置圖、庫(kù)房管道平面布置圖、機(jī)房剖面圖、冷間剖面圖、管道設(shè)備保溫圖、支架大樣圖、冷凝器、氣液調(diào)節(jié)站大樣圖、設(shè)備基礎(chǔ)圖?!? (此公式適用于 +10~- 30℃的溫度范圍) 冷凍間 設(shè)計(jì)溫度:- 23℃,室內(nèi)外溫差 Δ t=49℃ 圍護(hù)結(jié)構(gòu)傳熱系數(shù) K0= 49=(千卡 /米 2 確定圍護(hù)結(jié)構(gòu)絕熱層厚度 室外→室內(nèi) 20mm 水泥砂漿 (㎡℃ /W); tg— 圍護(hù)結(jié)構(gòu)高溫側(cè)的氣溫(℃); td— 圍護(hù)結(jié)低溫側(cè)的氣溫(℃); t1— 圍護(hù)結(jié)構(gòu)高溫側(cè)空氣的露點(diǎn)溫度(℃); b-熱阻的修正系數(shù),取 b=。 均大于最小熱阻,所選墻體材料及厚度合適?!?/W) δ i — 保溫層的厚度, m λ i— 保溫材料的導(dǎo)熱系數(shù), W/(m℃) ]; wA — 維護(hù)結(jié)構(gòu)傳熱面積( m2); a — 維護(hù)結(jié)構(gòu)兩側(cè)溫差修正系數(shù); w? — 維護(hù)結(jié)構(gòu)外側(cè)的計(jì)算溫度(℃) n? — 維護(hù)結(jié)構(gòu)內(nèi)側(cè)的計(jì)算溫度(℃) 維護(hù)結(jié)構(gòu)傳熱面積 wA 計(jì)算應(yīng)該符合下列規(guī)定: 1 屋面、地面和外墻的長(zhǎng)、寬度應(yīng)該自外墻外表面至外墻外表面或外墻外表面至內(nèi)墻中或內(nèi)墻中至內(nèi)墻中計(jì)算。 貨物熱流量計(jì)算表如下 房間 日進(jìn)出貨量 G(噸) 進(jìn)庫(kù)溫度t1(℃) 食品比焓h1( kJ/㎏ ) 終止溫度t2℃ 食品比焓h2( kJ/㎏ ) 冷卻時(shí)間 T(h) 冷負(fù)荷Q2(W) 冷凍間 1 冷凍間 2 冷藏間 3 冷藏間 4 冷藏間 5 合計(jì) 電機(jī)運(yùn)轉(zhuǎn)熱流量 電動(dòng)機(jī)運(yùn)轉(zhuǎn)熱流量計(jì)算公式如下: bPd ???? ? ?1000 式中 Φ — 電動(dòng)機(jī)運(yùn)轉(zhuǎn)熱流量( W); Pd— 電動(dòng)機(jī)額定功率( KW); 15 ? — 熱轉(zhuǎn)化系數(shù),電動(dòng)機(jī)在冷間內(nèi)時(shí)取 1; b— 電動(dòng)機(jī)運(yùn)轉(zhuǎn)時(shí)間系數(shù),對(duì)空氣冷卻器陪用的電動(dòng)機(jī)取 1。其計(jì)算式為: ts— 夏季空氣調(diào)節(jié)室外
點(diǎn)擊復(fù)制文檔內(nèi)容
公司管理相關(guān)推薦
文庫(kù)吧 www.dybbs8.com
備案圖鄂ICP備17016276號(hào)-1