【正文】
? = kg/m3 供入庫房的計算流量 凍結間 1 設備冷負荷 冷風機中氨液的流量 31 7 2 7 0 5 .7 8 1 0 0 .0 6 1 2 7 /1 2 1 8 .2 6oQM k g sq??? ? ? 凍結間 2 設備冷負荷 冷風機中氨液的流量 31 7 2 7 0 5 .7 8 1 0 0 .0 6 1 2 7 /1 2 1 8 .2 6oQM k g sq??? ? ? 30 凍藏間 1 設備冷負荷 冷風機中氨液的流量 31 2 9 5 2 . 5 4 1 03 0 . 0 1 5 0 5 /1 2 1 8 . 2 6M k g s???? 凍藏間 2 設備冷負荷 冷風機中氨液的流量 31 1 3 5 9 . 8 5 1 0 0 . 0 1 3 7 4 /4 1 2 1 8 . 2 6M k g s???? 凍藏間 3 設備冷負荷 冷風機中氨液的流量 31 2 9 5 2 . 5 4 1 05 0 . 0 1 5 0 5 /1 2 1 8 . 2 6M k g s???? 實際供入各庫房的氨液的體積流量分別為 通過公式?MV?求得 V1= m3/h V2=V5= m3/h 庫房回氣管道的實際流量 V1= m3/h V2= m3/h V3= m3/h V4= m3/h V5= m3/h 制冷系統(tǒng)的管道計算 管徑確定 計算管道內(nèi)徑 0 . 1 8 4 1 0 . 40 . 0 1 8 8 0 . 0 3 818nd?? ? ? 式中: nd管道內(nèi)徑 v計算狀態(tài)下制冷劑比容積( 3/m Kg ) mq制冷劑質量流量( /kgh ) 制冷劑允許流速( /ms),由《冷庫設計》中表 6表 62 確定。 低壓循環(huán)桶的選擇計算 ddddddd nWVnW Vd ???? ? ??? 01 00 4 = d d低壓循環(huán)桶直徑( m); V低壓級壓縮機的理論輸氣量( m3/h) ; λ 低壓級壓縮機的輸氣系數(shù); W d低壓循環(huán)桶內(nèi)氣體流速,立式低桶不大于 ; ξ d截面積系數(shù),立式低壓循環(huán)桶ξ d=; n低壓循環(huán)桶氣體進氣口的個數(shù),立式低壓循環(huán)桶為 1?!妫?]; △ 中間冷卻器蛇形管的對數(shù)平均溫度差( ℃ )。 h 各房間風機風量計算 : 房間 1 qv= =房間 2 qv= =房間 3 qv= =房間 4 qv= =房間 5 qv= = 冷風機風量的選型 根據(jù)《制冷空調產(chǎn)品設計手冊》 P400 及計算出的冷卻面積,風量和射程選出個房間的冷風機型號。℃) ];查表 417知排管換算系數(shù) 。 h),傳熱管用光鋼管,補充水量為循環(huán)水的 5%10%。 6. 選擇高壓級壓縮機。 系統(tǒng)采用循環(huán)水,由《冷藏庫設計》知,循環(huán)用水的水溫由當?shù)厥彝饪諝獾臐袂驕囟榷ā? 電動機運轉熱流量計算表 電動機運轉負荷 Q=1000*Pd*b*£ 房間 風機額定功率 Pd( KW) 熱轉化系數(shù)£ 電動機運轉時間系數(shù) b Q( W) 冷凍間 1 10 1 1 10000 冷凍間 2 10 1 1 10000 冷藏間 3 冷藏間 4 冷藏間 5 合計 20200 冷間操作熱流量 操作熱流量計算公式如下: ? ?rrnnwnkkdd nMhhVnnA ?????????? 1 ? 式中 Φ — 操作熱流量( W); Φ d— 每平方米照明熱流量,冷卻間、凍結間、冷藏間和冷間內(nèi)穿堂 可取 ㎡; nk— 每日開門換氣次數(shù); Vn— 冷間內(nèi)凈體積( m3); hw— 冷間外空氣的比焓( kJ/kg); hn— 冷間內(nèi)空氣的比焓( kJ/kg); M— 空氣幕效率修正系數(shù),可取 ; n? — 冷間內(nèi)空氣密度( kg/m3); 243 — 每日操作時間系數(shù),按每日操作 3小時計算; nr— 操作人員數(shù)量; Φ r— 每個操作人員產(chǎn)生的熱流量( W)冷間設計溫度高于或等與 5℃時,宜取 279W;冷間設計溫度低于 5℃時,宜取 395W。 2 樓板和內(nèi)墻長、寬度應自外墻內(nèi)表面至外墻內(nèi)表面或外墻內(nèi)表面至內(nèi)墻中或內(nèi)墻中至內(nèi)墻中計算。℃ ) 地帶 R 0 (㎡ 庫房地坪材料的選擇計算 地坪采用地下埋設自然通風管道給地坪保溫。 查表知高溫側空氣的露點溫度為 t1=℃ 圍護結構最小總熱阻: (㎡℃ /W) 370 ㎜厚磚砌墻 1 ?R=(㎡時 關鍵詞:壓縮 制冷 冷藏庫 節(jié)流 中間完全冷卻 Abstract T his design for the Zhangjiakou some 1000 ton low temperature cold storage design, was the production freezer storage, the cold storage has bee the facility which the essential food processing and stored for the daily life in, its system plex also used the working substance to be special, this design used the ammonia to take the working substance, as a result of its itself virose, the cold storage system safety production needed especially very much. The cold storage function is deepfreezes specially after the cold finishing meats, adjusts the pale prosperous season by the labor, guaranteed the market supplies, provide the foreign trade exportation and make using of the longterm store up. The pression type refrigeration is according to the refrigeration principle the pressor, the condenser, the throttle valve and the evaporator, as well as in order to cause the refrigeration potency to be higher, to move a safer supporting facility (for example 4 oil separator, liquid reservoir, gas fluid separator, circulation stock solution barrel, oil collector, puts air, pipe accessory, measuring appliance and so on) connects the position with the pipeline a closed refrigeration cycle. In the design process, to the refrigeration system each supporting facility shaping as well as in various storehouses refrigeration way choice has all made the optimized design from the refrigeration pressor choice, constructs the location according to the project the actual situation, the generalized analysis each refrigeration system in constructs under the location during detachment condition the feasible movement situation, finally in line with the economy, is detail drawingThe equipment base pilation. Keywords: Compression Freezer Throttle Complete cooling of the middle suitable, practical, the structure pact, the construction elegant appearance principle designs the chart, including refrigeration system schematic diagram, construction plan, equipment floorplan, engine room pipeline floorplan, storehouse pipeline floorplan, engine room sectional drawing, cold sectional drawing, pipeline equipment heat preservation chart, support detail drawing, condenser circulating water diagram, gas fluid regulating station 1 設計基本資料 設計目的: 畢業(yè)設計是工科類專業(yè)教學的重要環(huán)節(jié)之一,是對學生在校所學理論知識的全面總結和綜合檢驗。在設計過程中,從制冷壓縮機的選擇 到制冷系統(tǒng)各輔助設備的選型以及各庫房制冷方式的選擇上都做了優(yōu)化設計,根據(jù)項目建設場地的實際情況,綜合分析各制冷系統(tǒng)在建設場地客觀條件下的可行性運行情況,最后本著經(jīng)濟、適用、實用、結構緊湊、建筑美觀大方的原則設計出圖,包括制冷系統(tǒng)原理圖、建筑平面圖、設備平面布置圖、機房管道平面布置圖、庫房管道平面布置圖、機房剖面圖、冷間剖面圖、管道設備保溫圖、支架大樣圖、冷凝器、氣液調節(jié)站大樣圖、設備基礎圖?!? (此公式適用于 +10~- 30℃的溫度范圍) 冷凍間 設計溫度:- 23℃,室內(nèi)外溫差 Δ t=49℃ 圍護結構傳熱系數(shù) K0= 49=(千卡 /米 2 確定圍護結構絕熱層厚度 室外→室內(nèi) 20mm 水泥砂漿 (㎡℃ /W); tg— 圍護結構高溫側的氣溫(℃); td— 圍護結低溫側的氣溫(℃); t1— 圍護結構高溫側空氣的露點溫度(℃); b-熱阻的修正系數(shù),取 b=。 均大于最小熱阻,所選墻體材料及厚度合適?!?/W) δ i — 保溫層的厚度, m λ i— 保溫材料的導熱系數(shù), W/(m℃) ]; wA — 維護結構傳熱面積( m2); a — 維護結構兩側溫差修正系數(shù); w? — 維護結構外側的計算溫度(℃) n? — 維護結構內(nèi)側的計算溫度(℃) 維護結構傳熱面積 wA 計算應該符合下列規(guī)定: 1 屋面、地面和外墻的長、寬度應該自外墻外表面至外墻外表面或外墻外表面至內(nèi)墻中或內(nèi)墻中至內(nèi)墻中計算。 貨物熱流量計算表如下 房間 日進出貨量 G(噸) 進庫溫度t1(℃) 食品比焓h1( kJ/㎏ ) 終止溫度t2℃ 食品比焓h2( kJ/㎏ ) 冷卻時間 T(h) 冷負荷Q2(W) 冷凍間 1 冷凍間 2 冷藏間 3 冷藏間 4 冷藏間 5 合計 電機運轉熱流量 電動機運轉熱流量計算公式如下: bPd ???? ? ?1000 式中 Φ — 電動機運轉熱流量( W); Pd— 電動機額定功率( KW); 15 ? — 熱轉化系數(shù),電動機在冷間內(nèi)時取 1; b— 電動機運轉時間系數(shù),對空氣冷卻器陪用的電動機取 1。其計算式為: ts— 夏季空氣調節(jié)室外