作區(qū)溫度,℃,取=40℃,;—室外溫度,℃,取,(Kg/m3)。畢業(yè)的時(shí)間一天一天的臨近,畢業(yè)設(shè)計(jì)也接近了尾聲。在此,我衷心的感謝老師和同學(xué)給我的幫助。通過這次畢業(yè)設(shè)計(jì),使我明白學(xué)習(xí)是一個(gè)日積月累的過程,在以后都應(yīng)該不斷的學(xué)習(xí),努力提高自己知識(shí)水平和綜合素質(zhì)。此次畢業(yè)設(shè)計(jì),是我作為一名學(xué)生完成學(xué)業(yè)的最后一次作業(yè),它既是對(duì)學(xué)校所學(xué)知識(shí)的全面總結(jié)和綜合應(yīng)用,又為我今后走向社會(huì)的實(shí)際操作開啟了一個(gè)良好的開端。根據(jù)式(71)計(jì)算車間的全面換氣量: 2)確定中和面高度查文獻(xiàn)〔8〕(310),當(dāng)進(jìn)、排風(fēng)口面積未知時(shí)中和面高度Z=(~)H (72)式中 H—通風(fēng)房間的高度,m; Z —中和面至地平的高度,m。(5)校核節(jié)點(diǎn)處各支管的阻力平衡1)節(jié)點(diǎn)2: 此時(shí),認(rèn)為節(jié)點(diǎn)2已處于平衡狀態(tài)。 管徑取整,令D12=400mm,由附錄4查的管內(nèi)的實(shí)際流速v12=,單位長(zhǎng)度摩擦阻力Rm,12=。冬季的室外溫度為tw=5℃,工作地點(diǎn)空氣溫度tn=14℃,輻射強(qiáng)度為1400W/m2。對(duì)于阻力不平衡的管段還可以利用閥門調(diào)節(jié)平衡。 圖62 S2系統(tǒng)圖所選管徑應(yīng)符合的通風(fēng)管道統(tǒng)一規(guī)格。根據(jù)車間情況,只給S2系統(tǒng)設(shè)計(jì)送風(fēng)小室,送風(fēng)量為9773m3,選用3臺(tái)GFWZ46610初效過濾器并聯(lián),特性見表62:表62過濾器特性表額定風(fēng)量m3/h長(zhǎng)(mm)寬(mm)高(mm)初阻力(Pa)終阻力(Pa)350061061046451003. 百葉窗選擇設(shè)計(jì)車間選用防沙型鋁合金百葉窗?!妫? K=A (69)A、 R為實(shí)驗(yàn)系數(shù)和指數(shù),因不同加熱器而異。a.平均溫差法加熱空氣所需熱量 Q=G (64)式中,Q——熱量,kW;——空氣比熱,=(3)坡度。所以在澆注段送風(fēng)采用圓形風(fēng)管,電爐變壓器室、電氣間、砂處理控制室、型砂實(shí)驗(yàn)室等房間內(nèi)有電動(dòng)設(shè)備,采用矩形風(fēng)管可以節(jié)省空間。鋁板加工性能好,常用于防爆系統(tǒng)。℃);—房間空氣密度(Kg/?);—室外空氣密度(Kg/?);—室外空氣溫度(℃);—機(jī)械進(jìn)風(fēng)溫度(℃);—室內(nèi)空氣溫度(℃);—再循環(huán)空氣溫度(℃)。若該建筑的冷風(fēng)滲透量能滿足排風(fēng)要求,則可不設(shè)機(jī)械送風(fēng)裝置;2當(dāng)相鄰房間威懾組織進(jìn)風(fēng)裝置時(shí),可取其冷風(fēng)滲透量的50%作為自然補(bǔ)風(fēng);3對(duì)于每班運(yùn)行不足2小時(shí)的局部排風(fēng)系統(tǒng),經(jīng)過風(fēng)、熱平衡計(jì)算,對(duì)室溫沒很大影響時(shí),可不設(shè)機(jī)械送風(fēng)系統(tǒng);4設(shè)計(jì)局部排風(fēng)系統(tǒng),要有全局觀點(diǎn),不能片面追求大風(fēng)量,應(yīng)改進(jìn)局部排風(fēng)罩的設(shè)計(jì),在保證效果的前提下,盡量減少局部排風(fēng)量,以減小車間的進(jìn)風(fēng)量和排風(fēng)熱損失。,=㎡ 根據(jù)F12+F82≈F23,a=30176。,查附錄,ξ=90176。(2)選定最不利環(huán)路,本系統(tǒng)選擇1234567除塵器風(fēng)機(jī)為最不利環(huán)路。 (5)裝置的經(jīng)濟(jì)性:設(shè)備占用空間,投資,和運(yùn)行費(fèi)用,維護(hù)操作方便和回收綜合利用的情況等。(除塵器或凈化塔等)選擇及計(jì)算熔煉過程中會(huì)產(chǎn)生大量的煙塵和熱,并且熔煉過程中會(huì)加入有色金屬,會(huì)產(chǎn)生金屬氧化性粉塵和有害氣體。便于操作管理,粉塵的收集和節(jié)省費(fèi)用。在干混過程中,由于輾輪的輾混,攪拌也會(huì)產(chǎn)生大量的粉塵。Q326金屬履帶拋丸清理機(jī)的除塵風(fēng)量為2200?/h。密閉罩排風(fēng)量計(jì)算,本設(shè)計(jì)采用截面風(fēng)速法 (512)式中 qv—所需排風(fēng)量(㎡/s);A—密閉罩截面積(㎡);V—垂直于密閉罩面的平均風(fēng)速(m/s)。 F′—罩口擴(kuò)大的面積,即罩口面積減去熱射流的斷面面積(㎡)。(4)排風(fēng)罩應(yīng)力求結(jié)構(gòu)簡(jiǎn)單,造價(jià)低,便于安裝和維護(hù)。熱源上部接受式排風(fēng)罩,在工業(yè)車間內(nèi),污染源不僅散發(fā)粉塵及有害氣體,還有大量的熱的產(chǎn)生。局部排風(fēng)罩的主要形式有:密閉罩,柜式排風(fēng)罩,外部吸氣罩,熱源上部接受式排風(fēng)罩,吹吸式排風(fēng)罩。3)坡度。10) 排氣、除塵系統(tǒng)的吸氣點(diǎn)不能過多,一般不超過10個(gè),以利于各支管間阻力平衡。而全面排風(fēng)對(duì)整個(gè)車間進(jìn)行通風(fēng)換氣,用新鮮空氣把整個(gè)車間有害物濃度稀釋到最高允許濃度以下,且把污染空氣排至室外,通風(fēng)量大,且控制效果差,易造成大氣二次污染。2)冷風(fēng)滲透耗熱量按百分?jǐn)?shù)法計(jì)算,根據(jù)建筑物的特點(diǎn),查文獻(xiàn)[7]表中選取百分率為40%。把冷空氣加熱到室內(nèi)溫度所耗的熱量稱為冷風(fēng)滲透耗熱量。整個(gè)建筑物的基本耗熱量Q1′等于各個(gè)部分圍護(hù)結(jié)構(gòu)的基本耗熱量q′的總和。房間的得熱量包括:1) 太陽輻射進(jìn)入房間的熱量Q8。計(jì)算工廠設(shè)備的散熱量,可以合理的設(shè)計(jì)房間熱負(fù)荷,節(jié)省能源。電氣間,采用上部送風(fēng)方式。自然通風(fēng)是依靠室內(nèi)外溫差所形成的熱壓,或者室外風(fēng)力作用在建筑物上所形成的壓差,使室內(nèi)外的空氣進(jìn)行交換,從而改善室內(nèi)的空氣環(huán)境。排風(fēng)系統(tǒng)的設(shè)計(jì),必須以造價(jià)低,排風(fēng)量小和能最大限度地排除所散發(fā)的有害物為原則,只有在自然排風(fēng)不能排除有害物或技術(shù)上經(jīng)濟(jì)上不合理時(shí),則考慮采用機(jī)械排風(fēng)系統(tǒng)。2) 排風(fēng)口應(yīng)盡可能靠近有害物源或有害物濃度高的區(qū)域,把有害物迅速排至室外必要時(shí)進(jìn)行凈化處理。 查文獻(xiàn)〔7〕,該墻屬于Ⅱ類圍護(hù)結(jié)構(gòu),則=(℃)查文獻(xiàn)〔7〕,=6℃,外墻的最小熱阻為根據(jù)(21) R0R0,min,該外墻滿足保溫要求?!?w—供暖室內(nèi)計(jì)算溫度tn與圍護(hù)結(jié)構(gòu)內(nèi)表面溫度的允許溫差,℃。20mm水泥砂漿找平面,60mm粒狀高爐熔渣保溫層,25mm大型預(yù)制板,屋面?zhèn)鳠嵯禂?shù)K=(W/㎡ 鑄造車間在生產(chǎn)過程中散發(fā)出大量的粉塵,有害氣體等對(duì)勞動(dòng)者有害的物質(zhì)。全年工作天數(shù):360天鑄造工藝可分為三個(gè)基本部分,即鑄造金屬準(zhǔn)備、鑄型準(zhǔn)備和鑄件處理。工業(yè)生產(chǎn)過程伴隨著數(shù)以億噸計(jì)的有害物排放,這些有害物如果不進(jìn)行處理,會(huì)嚴(yán)重污染室內(nèi)外空氣環(huán)境,對(duì)人民身體健康造成極大的危害,特別是工礦企業(yè)。作者簽名: 日期: 年 月 日學(xué)位論文版權(quán)使用授權(quán)書本學(xué)位論文作者完全了解學(xué)校有關(guān)保留、使用學(xué)位論文的規(guī)定,同意學(xué)校保留并向國家有關(guān)部門或機(jī)構(gòu)送交論文的復(fù)印件和電子版,允許論文被查閱和借閱。最后進(jìn)行夏季校核關(guān)鍵詞: 熱負(fù)荷,通風(fēng),除塵,水力計(jì)算ABSTRACTA The design for the red flag foundry in xian is pleted dnd ventilation dust removal are designed. Combined with engineering and accessde relevant information, the related is determined heat suption of the palisade structure of the builing and the heat of the electric equipment are calculated. According to standards, the ventilation dust removal system design scheme, and piping layout is puts forword. According to the technology choice is decided , the exhaust air is calculate. Pipe section mode and dimensions,by the hydraulic calculation is decidarameters of room inside and outside. The palisade structure minimum thermal resistance is ced, purification equipment and fan models is choosed. The pipes and the installation way duct is chossed. Keywords: heating load ,ventilation,dust removal 畢業(yè)設(shè)計(jì)(論文)原創(chuàng)性聲明和使用授權(quán)說明原創(chuàng)性聲明本人鄭重承諾:所呈交的畢業(yè)設(shè)計(jì)(論文),是我個(gè)人在指導(dǎo)教師的指導(dǎo)下進(jìn)行的研究工作及取得的成果。結(jié)合工程,查閱相關(guān)的資料,確定室內(nèi)外的相關(guān)參數(shù),校核圍護(hù)結(jié)構(gòu)的最小熱阻,計(jì)算建筑物的圍護(hù)結(jié)構(gòu)耗熱量及建筑內(nèi)的電動(dòng)設(shè)備的散熱量。作 者 簽 名: 日 期: 指導(dǎo)教師簽名: 日 期: 使用授權(quán)說明本人完全了解 大學(xué)關(guān)于收集、保存、使用畢業(yè)設(shè)計(jì)(論文)的規(guī)定,即:按照學(xué)校要求提交畢業(yè)設(shè)計(jì)(論文)的印刷本和電子版本;學(xué)校有權(quán)保存畢業(yè)設(shè)計(jì)(論文)的印刷本和電子版,并提供目錄檢索與閱覽服務(wù);學(xué)??梢圆捎糜坝?、縮印、數(shù)字化或其它復(fù)制手段保存論文;在不以贏利為目的前提下,學(xué)??梢怨颊撐牡牟糠只蛉?jī)?nèi)容。作者簽名: 日期: 年 月 日導(dǎo)師簽名: 日期: 年 月 日注 意 事 項(xiàng)(論文)的內(nèi)容包括:1)封面(按教務(wù)處制定的標(biāo)準(zhǔn)封面格式制作)2)原創(chuàng)性聲明3)中文摘要(300字左右)、關(guān)鍵詞4)外文摘要、關(guān)鍵詞 5)目次頁(附件不統(tǒng)一編入)6)論文主體部分:引言(或緒論)、正文、結(jié)論7)參考文獻(xiàn)8)致謝9)附錄(對(duì)論文支持必要時(shí)):理工類設(shè)計(jì)(論文)正文字?jǐn)?shù)不少于1萬字(不包括圖紙、程序清單等)。該建筑主體兩層,一層為清理工部和砂處理工部,二層主要為熔煉工部和造型工部。為此,在熔煉過程中要進(jìn)行以控制質(zhì)量為目的的各種檢查測(cè)試,液態(tài)金屬在達(dá)到各項(xiàng)規(guī)定指標(biāo)后方能允許澆注。在鑄造車間,污染源及產(chǎn)生的污染物種類、散發(fā)量,根據(jù)各自的工藝特點(diǎn)、使用條件等的不同而有所差異。所以選用的傳熱系數(shù)要最大限度的滿足其使用要求,衛(wèi)生要求和經(jīng)濟(jì)要求?!?w Si—各層材料的蓄熱系數(shù),W/(㎡℃)。對(duì)于輔助部分如一層更衣室,砂處理電控室,二層實(shí)驗(yàn)室等采用送風(fēng)系統(tǒng)承擔(dān)補(bǔ)風(fēng)量,冬季送熱風(fēng),夏季利用室內(nèi)空調(diào)進(jìn)行降溫。凡散發(fā)劇毒性或易燃爆氣體的設(shè)備和場(chǎng)所的均應(yīng)設(shè)立單獨(dú)的排風(fēng)系統(tǒng)。另外,自然通風(fēng)的換氣量一般受室外氣象條件的影響,通風(fēng)效果不穩(wěn)定。對(duì)于二層男女廁所,制樣間等對(duì)溫度要求不高的房間,給窗戶上設(shè)排風(fēng)機(jī)。3) 加熱由門,孔洞和其他相鄰房間浸入的冷空氣的耗熱量Q3。4)生產(chǎn)車間最小負(fù)荷班的工藝設(shè)備散熱量Q11。 朝向修正耗熱量是太陽輻射對(duì)建筑物圍護(hù)耗熱量的修正。根據(jù)建筑物結(jié)構(gòu)特點(diǎn),本設(shè)計(jì)滲透耗熱量占圍護(hù)結(jié)構(gòu)總耗熱量的百分率取40%。(1)熔煉工段工頻感應(yīng)電爐的散熱量Q=860Ncos (44)式中 N—感應(yīng)電爐額定功率,KW;—感應(yīng)電路的總效率,% ,根據(jù)工藝資料采取;cos—補(bǔ)償后的功率因數(shù),~。排風(fēng)系統(tǒng)(除塵系統(tǒng))設(shè)計(jì)原則:1)風(fēng)機(jī)一般應(yīng)布置在凈化器后,以減輕磨損或腐蝕;2)風(fēng)管宜垂直或傾斜敷設(shè),傾斜敷設(shè)應(yīng)與水平面夾角大于45176。直徑或大邊長(zhǎng)>400mm,間距≤3m。4)對(duì)于相同管徑的支架,等距離排列,間距應(yīng)≥200mm。柜式排風(fēng)罩,實(shí)質(zhì)上也是密閉罩,是密閉罩的一種特殊形式,只有一面敞開或開著的工作孔。局部排風(fēng)罩的設(shè)計(jì)原則:(1)局部排風(fēng)罩應(yīng)盡可能包圍或靠近有害物,使有害物源局限于較小的局部空間。 熔煉工段主要產(chǎn)生大量的煙塵和熱,在爐口設(shè)置熱源上部接受式排風(fēng)罩。 對(duì)流散熱量Q (510)式中 F—熱源的對(duì)流散熱面積(㎡); Δt—熱源表面與周圍空氣的溫度差(℃); a—表面?zhèn)鳠嵯禂?shù)〔KJ/(㎡熔煉過程中產(chǎn)生大量的煙塵和熱。顎式破碎機(jī)下部排料至受料設(shè)備的卸料點(diǎn)也會(huì)產(chǎn)生粉塵,而排料至輸送帶的物料落差<1m,直接給料。根據(jù)式(512)得, 混砂機(jī)所需的排風(fēng)量q=3600=2934(?/h)、澆注和造型工段排風(fēng)量計(jì)算制芯采用普通的射芯機(jī),芯砂中含有一定的水分,所以產(chǎn)生粉塵不多,產(chǎn)生有害氣體也不多,故不許設(shè)置排風(fēng)。本設(shè)計(jì)中,熔煉工段產(chǎn)生大量的煙塵,熱量,所以單獨(dú)設(shè)置除塵系統(tǒng)。所以必須經(jīng)過凈化處理,達(dá)到國家對(duì)有害物規(guī)定的排放標(biāo)準(zhǔn)時(shí)排入大氣。 CIn—凈化裝置進(jìn)口的含塵濃度,(g/?)。管段12根據(jù)3420?/h、v1=15m/s ,求出管徑。查得ξ12= ,ξ82==管內(nèi)動(dòng)壓 =(Pa)管段12的阻力 +=(Pa)其他管段阻力計(jì)算同管段12方法相同,在此不一一計(jì)算。對(duì)于阻力不平衡的管段還可以利用平衡閥調(diào)節(jié)。7為充分利用排風(fēng)余熱,節(jié)約能源,在可能條件下應(yīng)設(shè)置熱回收裝置。K); tp——排出的空氣溫度(K); t0——進(jìn)入的空氣溫度(K)。硬聚氯乙烯塑料管的優(yōu)點(diǎn)是表面光滑,制作簡(jiǎn)單,但不耐高溫,不耐寒,在太