freepeople性欧美熟妇, 色戒完整版无删减158分钟hd, 无码精品国产vα在线观看DVD, 丰满少妇伦精品无码专区在线观看,艾栗栗与纹身男宾馆3p50分钟,国产AV片在线观看,黑人与美女高潮,18岁女RAPPERDISSSUBS,国产手机在机看影片

正文內(nèi)容

奧康軟啟動(dòng)ims2productfamiliarisation-資料下載頁

2024-12-08 08:47本頁面
  

【正文】 范圍 Default Setting 默認(rèn)值設(shè)定 0 (Parameter set selection) (參數(shù)設(shè)定選擇 ) Description 說明 : Determines the functionality of programmable Input A.選定輸入 A的功能 0 = Parameter set selection 參數(shù)設(shè)定選擇 1 = Auxiliary trip (.) 輔助性跳閘設(shè)置 (.) 2 = Auxiliary trip (.) 輔助性跳閘設(shè)置 (.) 3 = Emergency mode operation 應(yīng)急模式運(yùn)轉(zhuǎn) Input A can be used to activate one of three IMS2 functions:輸入 A可用于激活 IMS2三種功能中的一種 Assign Function 24 Input A Functionality to the desired feature. 可在功能 24 輸入 A功能 中設(shè)定需要的功能 IMS2 Product Familiarisation 33 Parameter Set Selection 參數(shù)設(shè)定選擇 24. Input A Functionality 輸入 A功能 [Starter Functionality]起動(dòng)器功能 Description 說明 : Activates the secondary motor settings (Functions 80 ~ 88). 激活次級電機(jī)設(shè)置 (功能 80~88) 0 = Parameter set selection 參數(shù)設(shè)定選擇 1 = Auxiliary trip (.) 輔助性跳閘設(shè)置 (.) 2 = Auxiliary trip (.) 輔助性跳閘設(shè)置 (.) 3 = Emergency mode operation 應(yīng)急模式運(yùn)轉(zhuǎn) When set = 0 (Parameter set selection), closing Input A will activate the IMS2 secondary motor settings. 當(dāng)設(shè)定 =0(參數(shù)設(shè)定選擇 ), 關(guān)閉的輸入 A將激活 IMS2次級電機(jī)設(shè)定 Activation of the secondary motor settings can only be done while the motor is stopped. 只有在電機(jī)停止的時(shí)候才能激活次級電機(jī)設(shè)定 80. Motor Full Load Current 電機(jī)滿載電流 [Secondary Motor Settings]次級電機(jī)設(shè)定 81. Current Limit 電流限定 [Secondary Motor Settings]次級電機(jī)設(shè)定 82. Initial Start Current 初始起動(dòng)電流 [Secondary Motor Settings]次級電機(jī)設(shè)置 83. Start Ramp Time 斜坡起動(dòng)時(shí)間 [Secondary Motor Settings]次級電機(jī)設(shè)定 84. Stop Ramp Time 斜坡停止時(shí)間 [Secondary Motor Settings]次級電機(jī)設(shè)定 85. Motor Start Time Constant 電機(jī)起動(dòng)時(shí)間常數(shù) [Secondary Motor Settings]次級電機(jī)設(shè)定 86. Phase Imbalance Sensitivity 相位不平衡靈敏度 [Secondary Motor Settings]次級電機(jī)設(shè)定 87. Undercurrent Protection 欠流保護(hù) [Secondary Motor Settings]次級電機(jī)設(shè)定 88. Electronic Shearpin Protection 電子銷保護(hù) [Secondary Motor Settings]次級電機(jī)設(shè)定 IMS2 Product Familiarisation 34 Auxiliary Trip 輔助性跳閘裝置 24. Input A Functionality 輸入 A功能 [Starter Functionality]起動(dòng)器功能 Description 說明 : Trips the IMS2. IMS2跳閘 When set = 1 (Auxiliary trip .), closing Input A will cause the IMS2 to trip. 當(dāng)設(shè)定 =1(輔助性跳閘 .), 關(guān)閉的輸入 A 將使 IMS2跳閘 When set = 2 (Auxiliary trip .), opening Input A will cause the IMS2 to trip. 當(dāng)設(shè)定 =2(輔助性跳閘 .), 打開的輸入 A將使 IMS2跳閘 0 = Parameter set selection 參數(shù)設(shè)定選擇 1 = Auxiliary trip (.) 輔助性跳閘 (.) 2 = Auxiliary trip (.) 輔助性跳閘 (.) 3 = Emergency mode operation 應(yīng)急模式運(yùn)轉(zhuǎn) IMS2 Product Familiarisation 35 Auxiliary Trip 輔助性跳閘 Performance of the Auxiliary Trip feature can be adjusted using Functions 36 and 94. 可使用功能 36和 94對輔助性跳閘的功能進(jìn)行調(diào)整 0 12 36. Auxiliary Trip Mode 輔助性跳閘 [Protection Settings]保護(hù)設(shè)置 Range 范圍 Default Setting 默認(rèn)值設(shè)置 0 (Active at all times) 0 = Active at all times 全天候激活 1 = Active during start, run amp。 stopping (disabled while stopped) 起動(dòng) , 運(yùn)行及停止時(shí)激活 (停止后禁用 ) 2 = Active during run only 僅在運(yùn)行時(shí)激活 3 = Active 30 seconds after the start mand 運(yùn)行命令后激活 30秒 4 = Active 60 seconds after the start mand 運(yùn)行命令后激活 60秒 5 = Active 90 seconds after the start mand 運(yùn)行命令后激活 90秒 6 = Active 120 seconds after the start mand 行命令后激活 120秒 7 = Active 180 seconds after the start mand 運(yùn)行命令后激活 180秒 8 = Active 240 seconds after the start mand 運(yùn)行命令后激活 240秒 9 = Active 300 seconds after the start mand 運(yùn)行命令后激活 300秒 10 = Active 600 seconds after the start mand 運(yùn)行命令后激活 600秒 11 = Active 900 seconds after the start mand 運(yùn)行命令后激活 900秒 12 = Active 1200 seconds after the start mand 運(yùn)行命令后激活 1200秒 0 240 seconds秒 94. Auxiliary Trip Mode 輔助性跳閘 [Protection Settings]保護(hù)設(shè)置 Range 范圍 Default Setting 默認(rèn)值設(shè)定 0 seconds秒 IMS2 Product Familiarisation 36 Emergency Mode Operation 應(yīng)急模式運(yùn)轉(zhuǎn) 24. Input A Functionality 輸入 A功能 [Starter Functionality]起動(dòng)器功能 Description 說明 : Causes the IMS2 to start, run and continue to operate while ignoring specified trip conditions. 忽略特殊跳閘情況 , 使 IMS2起動(dòng) , 運(yùn)行和繼續(xù)運(yùn)轉(zhuǎn) When set = 3 (Emergency Mode operation), closing Input A will cause the IMS2 to start, run and continue to operate even when specified trip conditions occur. 當(dāng)設(shè)定 =3(應(yīng)急模式運(yùn)轉(zhuǎn) ),即使當(dāng)特殊跳閘情況出現(xiàn)時(shí) , 關(guān)閉的輸入 A也將使IMS2起動(dòng) ,運(yùn)行和繼續(xù)運(yùn)轉(zhuǎn) 0 4 114. Emergency Mode Format 應(yīng)急模式格式 [Restricted Functions]受限功能 Range 范圍 Default Setting 默認(rèn)值設(shè)定 0 (Off)(關(guān)閉 ) 0 = Off 關(guān)閉 3 = Trip Group A, B amp。 C 跳閘群 A,Bamp。C 1 = Trip Group A 跳閘群 A 4 = All trips 所有
點(diǎn)擊復(fù)制文檔內(nèi)容
教學(xué)課件相關(guān)推薦
文庫吧 www.dybbs8.com
備案圖鄂ICP備17016276號-1