【正文】 re should be so arranged that it can transmit dead, wind and imposed loads in a direct manner to the foundations. The general arrangement should ensure a robust and stable structure that will not collapse progressively under the effects of misuse or accidental damage to any one element. The engineer should consider engineer site constraints, buildability2, maintainability and demissioning. The engineer should take account of his responsibilities as a ‘Designer’ under the Construction (Design amp。 Part Supplementary rules for plain or lightly reinforced concrete structures。 Part Supplementary rules for structural fire design。IStructE EC2 (Concrete) Design Manual 1 1 Introduction and scope Aims of the Manual This Manual provides guidance on the design of reinforced and prestressed concrete building structures. Structures designed in accordance with this Manual will normally ply with DD ENV 199211: 19921 (hereinafter referred to as EC2). Eurocode system The structural Eurocodes were initiated by the European Commission but are now produced by the Comit233。 Part Supplementary rules for precast concrete elements and structures。 Part Reinforced and prestressed concrete bridges。 Management) Stability Lateral stability in two orthogonal directions should be provided by a system of strongpoints within the structure so as to produce a braced nonsway structure, in which the columns will not be subject to significant sway moments. Strongpoints can generally be provided by the core walls enclosing the stairs, lifts and service ducts. Additional stiffness can be provided by shear walls formed from a gable end or from some other external or internal subdividing wall. The core and shear walls should preferably be distributed throughout the structure and so arranged that their bined shear centre is located approximately on the line of the resultant in plan of the applied overturning forces. Where this is not possible, the resulting twisting moments must be considered when calculating the load carried by each strongpoint. These walls should generally be of reinforced concrete not less than 180mm thick to facilitate concreting, but they may be of 215mm brickwork or 190mm solid blockwork properly tied and pinned up to the framing for low to mediumrise buildings. Strongpoints should be effective throughout the full height of the building. If it is essential for strongpoints to be discontinuous at one level, provision must be made to transfer the forces to IStructE EC2 (Concrete) Design Manual 5 other vertical ponents. It is essential that floors be designed to act as horizontal diaphragms, particularly if precast units are used. Where a structure is divided by expansion joints each part should be structurally independent and designed to be stable and robust without relying on the stability of adjacent sections. Robustness All members of the structure should be effectively tied together in the longitudinal, transverse and vertical directions. A welldesigned and welldetailed castin situ structure will normally satisfy the detailed tying requirements set out in subsection . Elements whose failure would cause collapse of more than a limited part of the structure adjacent to them should be avoided. Where this is not possible, alternative load paths should be identified or the element in question strengthened. Movement joints Movement joints may need to be provided to minimize the effects of movements caused by, for example, shrinkage, temperature variations, creep and settlement. The effectiveness of movement joints depends on their location. Movement joints should divide the structure into a number of individual sections, and should pass through the whole structure above ground level in one plane. The structure should be framed on both sides of the joint. Some examples of positioning movement joints in plan are given in Fig. . Movement joints may also be required where there is a significant change in the type of foundation or the height of the structure. For reinforced concrete frame structures in UK conditions, movement joints at least 25mm wide should normally be provided at approximately 50m centres both longitudinally and transversely. In the top storey and for open buildings and exposed slabs additional joints should normally be provided to give approximately 25m spacing. Joint spacing in exposed parapets should be approximately 12m. Joints should be incorporated in the finishes and in the cladding at the movement joint locations. Fire resistance and durability For the required period of fire resistance (prescribed in the Building Regulations), the structure should: ? have adequate loadbearing capacity ? limit the temperature rise on the far face by sufficient insulation, and IStructE EC2 (Concrete) Design Manual 6 ? have sufficient integrity to prevent the formation of cracks that will allow the passage of fire and gases. Fig. Location of movement joints The design should take into account the likely deterioration of the structure and its ponents in their environment having due regard to the anticipated level of maintenance. The following interrelated factors should be considered: ? the required performance criteria ? the expected environmental conditions ? the position, properties and performance of materials ? the shape of members and detailing ? the quality of workmanship ? any protective measure ? the likely maintenance during the intended life. Concrete of appropriate quality with adequate cover to the reinforcement should be specified. The above requirements for durability and fire resistance may dictate sizes for members greater than those r
點(diǎn)擊復(fù)制文檔內(nèi)容
畢業(yè)設(shè)計(jì)相關(guān)推薦
文庫吧 www.dybbs8.com
備案圖片鄂ICP備17016276號(hào)-1