【正文】
0AABMP4C11AABMP4C13AABMP4C16AABMP4C20AAAMP4C25AAAMP4C31AAAMP4C40AAAMP4C50AAA2.)2.)2.)2.)2.)MX pro 4V3,0MX pro 4V4,0MX pro 4V5,5MX pro 4V7,5MX pro 4V118 P01 004 MX pro 4V15MX pro 4V18MX pro 4V22MX pro 4V30MX pro 4V37MX pro 4V45MX pro 4V55MX pro 4V75MX pro 4V90/110MX pro 4V110/132MX pro 4V132/160MX pro 4V160/200MX pro 4V200/250MX pro 4V250/315MX pro 4V315/400MX pro 4V400/500MX pro 4V500/6301.) The Matrix operating panel pDRIVE BE11 is to be ordered separately.2.) The braking option is an optional ponent.11Highperformance drives in a cubicle design for industry, machinebuilding and automationThe choice of pDRIVE MX pro frequency invertersprises various cubicle designs in addition to the builtin and wallmounting designs.The basic design of the cubicle unit pDRIVEMX multipro plies with protection degree IP23 andIP54 and includes a main switch, mains fuses, AC or DCchoke and motor terminals as well as terminals for theconnection of a braking resistor. Further fixtures such asline contactor, motor filter, various control options,alternatively with fieldbus, safety relay, cubicle heating,and much more can be selected from the correspondinglist of options.In addition, special designs are available such as changedcubicle colour, cubicle cooling via an air conditioner or anair/water heat exchanger, and customerspecific controlequipment.HTHDOptimized cubicle designs that fit your range of applications:Device featuresCubicle systemThe Rittal TS8 cubicle system with additional internal reinforcement elementsand slide bars for easy installation and removal of the inverter devices andother power ponents can be added to any existing cubicle systems.For safe control, clear parameterization and fast diagnosis, the matrixoperating panel is installed in the cubicle door at an ideal height. Atransparent protective cover and an adjustable locking code prevent theunintended parameter adjustments.The following status displays are permanently present:Ready / Run / Trip.3 analog actual values can be parameterized for the display of current,voltage, power, load, speed, operating hours meter, and much more and thusprovide information on the relevant drive data at any time.Generous space is provided to connect the power cables. The extensibilityand accessibility of the control terminals is also taken into consideration.In the standard design, the cables are to be connected at the bottom of theinverter.All cubicle units are equipped with a large, swivelling control panel thatpermits subsequent extensions.8 P01 004 Operation / parameterizationDisplays on the cubicleConnectionExtensibility12General technical dataMains voltageMaximum currentGeneral design380 V 15% up to 415 V +10% for TT, TN or IT mainsPower 1: 150 % for 60 s per 10 minutes, 165 % for 2 secondsPower 2: 120 % for 60 s, 135 % for 2 s (from MX multipro 4V90/110)Cubicle system Rittal TS8 in RAL 7035Controls in the cubicle door with additional protective cover,Cable entry from below, cubicle depth of 600 mmAir intake through grid in cubicle door,Air blow through mounted air guidance hood,Cubicle height of 2155 mmAir intake through filter mats in cubicle door,Air blow through top mounted fanCubicle height of 2260 mmAir intake through cubicle basement,Air blow through mounted air guidance hood,Cooling of the control part by means of filter fans in the cubicle door,Cubicle height of 2355 mm incl. 200 mm basement0 … +40176。C with derating possibleControl terminals directly on the inverter or alternatively in the cubicle, controlterminals can be extended, fieldbus connection via Modbus, Profibus DP orCANopenCE, RFI filter installed for 2nd Industrial environment C3pDRIVE MX pro frequency inverter, main switch, mains fuses, AC or DCchoke, motor terminals, control panel, terminals for an external brakingresistor (only MX multipro 4V22...4V160/200) and matrix operating panel inthe door.Line contactor, additional RFI filter, braking unit (from 200 kW, partially withadditional field), AMF (output motor filter, partially with additional field),terminal extensions, fieldbus, emergency stop button, safe standstill (controlcategory 3 according to EN 9541 for Safe Standstill (stop category 0 or 1)),cubicle lighting, cubicle heating, and much more.Motor powerP1 / P222 kW30 kW37 kW45 kW55 kW75 kW90/110 kWOutput currentI1 / I248 A66 A79 A94 A116 A160 A179/215 A215/259 A129/314 A314/387 A387/481 A481/616 A616/759 A759/941 A941/1188 ADimensions in mmWidth6006006006006006006006006006008008001000 (1400)1000 (1400)1200 (1600)Depth Height600600600IP23 with air guidance hood 2155 mm600600600600600600600600600600600IP54 with filter mats and additional fan 2260 mm600IP23 designIP54 designIP54 with separated air flowOperating temperatureInterfacesStandardsHTHD8 P01 004 Standard equipmentOptionspDRIVEMX multipro 4V22SMX multipro 4V30SMX multipro 4V37SMX multipro 4V45SMX multipro 4V55SMX multipro 4V75SMX multipro 4V90/110SMX multipro 4V110/132S 110/132 kWMX multipro 4V132/160S 132/160 kWMX multipro 4V160/200S 160/200 kWMX multipro 4V200/250S 200/250 kWMX multipro 4V250/315S 250/315 kWMX multipro 4V315/400S 315/400 kWMX multipro 4V400/500S 400/500 kWMX multipro 4V500/630S 500/630 kWValues in brackets for IP54 with separated air flowIP54 with separated air flow 2355 mm13Operation of the pDRIVE MX eco amp。 pro frequency inverters does not call for special requirementsand is geared towards utmost ease of use. In this way you have a full overview of the device in each situation.The keypad of the pDRIVE MX eco amp