freepeople性欧美熟妇, 色戒完整版无删减158分钟hd, 无码精品国产vα在线观看DVD, 丰满少妇伦精品无码专区在线观看,艾栗栗与纹身男宾馆3p50分钟,国产AV片在线观看,黑人与美女高潮,18岁女RAPPERDISSSUBS,国产手机在机看影片

正文內(nèi)容

35kv輸電線路畢業(yè)設計論文-在線瀏覽

2025-01-26 16:48本頁面
  

【正文】 ined with the actual situation of the project, to ensure reliable power supply, flexible scheduling to meet the technical requirements. The design lines of 35kV transmission lines, and its safe operation is directly related to the reliability of power supply. The main content of the transmission line design corresponds to a bination of certain cable cross sections, terrain conditions, and weather conditions in the calculation of the meteorological conditions and the span stress on cables and sag。本次輸電線路設計的主要內(nèi)容在對應于一定的導線截面、地形條件、和氣象條件的組合,計算各氣象條件和檔距下導地線的應力及弧垂;根據(jù)計算結(jié)果繪制應力弧垂曲線及安裝曲線指導工程施工;制作弧垂曲線模板,用弧垂曲線模板在平斷面圖上排定桿塔位置;對線路的使用條件全面檢查和校驗,保證各使用條件在規(guī)定的允許范圍內(nèi);根據(jù) 所處地區(qū)的土壤電阻率,合理鋪設桿塔接地體,計算出線路耐雷水平及雷擊跳閘率。 I 內(nèi)容提要 本畢業(yè)設計以設計任務書為依據(jù),以國家經(jīng)濟建設的方針、政策、技術規(guī)定準繩,結(jié)合工程實際情況,保證供電可靠,調(diào)度靈活,滿足各項技術要求。 本次設計線路為 35kV輸電線路,其安全運行直接關系到供電的可靠性。 本文主要根據(jù)現(xiàn)有的技術規(guī)程及資料對架空線路的防雷、金具及桿塔的原理、技術方面進行論述,其主要內(nèi)容為導線地線設計、金具設計、桿塔設計、基礎設計、防雷設計、編制鐵塔施工技術手冊。 draw stress sag curve based on the results and installation of the curve for engineering construction。 prehensive inspection and verification of the conditions of use of the line to ensure that the respective conditions within the allowable range。 circuit design。 groun 目 錄 內(nèi)容 提 要 ...................................................................................................... I SUMMARY .................................................................................................II 1 總述 ......................................................................................................... 1 設計依據(jù) ............................................................................................... 1 設計范圍和建設規(guī)模 ........................................................................... 1 路徑說明 ............................................................................................... 1 沿線交叉跨越情況 ............................................................................... 2 變得所進出線說明 ............................................................................... 2 導線的 設計氣象條件 ........................................................................... 2 導線及地線的選擇 ............................................................................... 3 導線及地線應力 ................................................................................... 3 2 導線 ......................................................................................................... 5 導線的比載 ........................................................................................... 5 計算臨界檔距,判斷控制氣象 ............................................................ 6 繪制應力弧垂曲線 ............................................................................... 8 繪制導線安 裝曲線 ..............................................................................10 3 地線的設計 .............................................................................................12 地線的比載 ..........................................................................................12 計算臨界檔距,判斷控制氣象 條件 ...................................................13 繪制應力弧垂曲線 ..............................................................................16 繪制 地線安裝曲線 ..............................................................................17 4 金具 ......................................................................................................19 絕緣子的選擇和計算 ..........................................................................19 防震錘 .................................................................................................21 5 防雷與接地 .............................................................................................23 防雷設計 ..............................................................................................23 接地設計 ..............................................................................................23 6 導線對地及交叉跨越距離及保護 ..........................................................24 導線對地及交叉跨越距離 ..................................................................24 1 交叉跨越及保護 ..................................................................................25 7 桿塔與基礎 ...........................................................................................27 桿塔設計 ..............................................................................................27 電桿的制造 、 運輸與安裝 ..................................................................28 鐵塔的設計 、 制造和安裝說明 .........................................................29 桿塔制造和施工要求 ..........................................................................30 基礎設計 ..............................................................................................30 心得體會 ....................................................................................................33 參考文獻 ....................................................................................................34 致謝 ............................................................................................................35 1 1 總述 設計依據(jù) 1) 17 號文關于文市 110KV變至水變 35KV 線路工程設計的批復。 設計范圍和建設規(guī)模 本工程為新建 35kV 線路工程 ,從 110kV 文市變 35kV 龍門架起 ,架線至原水文35kV線 P59,然后利用 P59~ P11 老通道架線至水文線 P11,然后接入水車 35kV 變。架空導線采用LGJ150/20 型鋼芯鋁鉸線,電纜采用 YJV22353*185 型,地線采用 1*型鍍鋅鋼絞線 (簡稱 GJ35),該新建線路長度為 (其中電纜長度為 120 米),本工程一次性架設完成,地線逐基直接接地。 路徑說明 線路中途主要經(jīng)過大竹山、巖頭壩、蔣家、大車田、吉田、伍家灣、水車等地,整體走向為南北走向,航空距離為 ,曲折系數(shù) 。線路繼續(xù)前行約 1 公里,為了避開采石廠炮區(qū),線路其間經(jīng)過幾次轉(zhuǎn)角后至原水文 35kV線 P59,再利用原 P59~ P11 老通道走線,中 途經(jīng)大車田、吉田、伍家灣、璃碧洞、山燕頭、長洲等地至水文線 P11,在 P11 桿位上左轉(zhuǎn)后接至水車 35kV 電纜終端塔。 全線地形比例為:一般山地 20%;丘陵 60%;泥水 20%。線路區(qū)域上為穩(wěn)定地塊,地震基本烈度小于 6 度。總體看,線路沿線工程地質(zhì)條件較好。 沿線交叉跨越情況 沿線交叉跨越情況見表 21。詳見文市 110kV變進出線平面布置示意圖。各項氣象條件取值見表本工程地處 GX 東北方,屬丘陵地帶,線路經(jīng)過的地形黃海高程最高未超過 400m。導、地線機械物理特性見表 22。如表 23 所示。具體表述如下圖 所示; 繪制應力弧垂曲線 為了保證曲線比較準確而又不使計算量過大,檔距 l
點擊復制文檔內(nèi)容
公司管理相關推薦
文庫吧 www.dybbs8.com
備案圖鄂ICP備17016276號-1