【正文】
Dj.302Ccs Aw Qc(i) 三、照明散熱形成的冷負(fù)荷根據(jù)照明燈具的類型和安裝方式的不同,其冷負(fù)荷計(jì)算式分別為:白熾燈: =1000℃),由附錄【1】228查得; AW——窗口面積,㎡;——外玻璃窗的冷負(fù)荷的逐時值,℃,可由附錄[1]210查得。以多功能廳為例計(jì)算結(jié)果見表22表22內(nèi)墻冷負(fù)荷表 朝向分項(xiàng)時刻11:0012:0013:0014:0015:0016:0017:00北內(nèi)墻穩(wěn)態(tài)傳熱Δt KWAw Qc(i) 西內(nèi)墻穩(wěn)態(tài)傳熱Δt KWAw Qc(i) 東內(nèi)墻穩(wěn)態(tài)傳熱Δt KWAw Qc(i) 外玻璃窗逐時傳熱引起的冷負(fù)荷在室內(nèi)外溫差的作用下, 玻璃窗瞬變熱形成的冷負(fù)荷可按下式計(jì)算: W (23)式中: ——外玻璃窗的逐時冷負(fù)荷,W; KW——玻璃的傳熱系數(shù),W /( m178。以多功能廳為例計(jì)算結(jié)果見表21表21外墻冷負(fù)荷表朝向分項(xiàng)時刻11:0012:0013:0014:0015:0016:0017:00北外墻冷負(fù)荷t Δtdka kp tc tr Δt KWAwQc(i) 西外墻冷負(fù)荷tΔtdka kptc tr Δt KWAw Qc(i) 東外墻冷負(fù)荷tΔtdka kptc tr Δt KWAw Qc(i) 南外墻冷負(fù)荷t34Δtdka kptc tr Δt KW Aw98 Qc(i) 內(nèi)墻,樓板等室內(nèi)傳熱維護(hù)結(jié)構(gòu)形成的瞬時冷負(fù)荷當(dāng)空調(diào)房間的溫度與相鄰非空調(diào)房間的溫度大于3℃時,要考慮由內(nèi)維護(hù)結(jié)構(gòu)的溫差傳熱對空調(diào)房間形成的瞬時冷負(fù)荷,可按如下傳熱公式計(jì)算: W (22)式中: A——內(nèi)圍護(hù)結(jié)構(gòu)的傳熱面積,m178。 夏季冷負(fù)荷的計(jì)算一、 圍護(hù)結(jié)構(gòu)瞬變傳熱形成的冷負(fù)荷外墻和屋面瞬變傳熱引起的冷負(fù)荷在日射和室外氣溫綜合作用下,外墻和屋面瞬變傳熱引起的逐時冷負(fù)荷可按下式計(jì)算: W (21)式中:——外墻和屋面瞬變傳熱引起的逐時冷負(fù)荷,W; A——外墻和屋面的面積,㎡; K——外墻和屋面的傳熱系數(shù),W/(㎡56′,;夏季:,℃, 空調(diào)室外計(jì)算濕球溫度26℃,;冬季: kPa,空調(diào)室外計(jì)算干球溫度8℃。 設(shè)計(jì)參數(shù)一、氣象參數(shù)北緯34176。==(㎡.k/w)由此可知o,故所選外墻滿足要求。℃)——冬季維護(hù)結(jié)構(gòu)溫差修正系數(shù),℃;△ty——冬季室內(nèi)計(jì)算溫度與圍護(hù)結(jié)構(gòu)內(nèi)表面之間的允許溫度, 186。 圖12 外墻構(gòu)造最小傳熱熱阻:式中:tn——冬季室內(nèi)計(jì)算溫度,℃;tw——圍護(hù)結(jié)構(gòu)冬季室外計(jì)算溫度,℃;ay——圍護(hù)結(jié)構(gòu)內(nèi)表面換熱系數(shù), W/(m178。構(gòu)造如下: ①外粉刷20mm;②加氣混凝土200mm;③內(nèi)粉刷20mm。==(㎡.k/w)由此可知o,故所選屋頂滿足要求。屬于Ⅱ型,傳熱系數(shù)K=(㎡.K)。一、 屋頂?shù)男:宋蓓數(shù)慕Y(jié)構(gòu)如圖11所示。其地下一層為車庫和設(shè)備用房,地上一層為商鋪,二、三層為雅間和多功能廳,四到十層為標(biāo)準(zhǔn)間和會議室。但由于本人水平有限,在設(shè)計(jì)過程中難免有錯誤之外,懇請老師和同學(xué)指正為謝!第1章 工程概況167。以設(shè)計(jì)計(jì)算結(jié)果及建筑的具體情況為依據(jù),合理布置設(shè)備及通風(fēng)管路,最后繪制出清晰明確的工程圖紙。因此迫切需要為商業(yè)建筑物安裝配置節(jié)能、健康、舒適的中央空調(diào)系統(tǒng)來滿足人們對高生活水平的追求。 商業(yè)建筑不斷的增多,以及人們對室內(nèi)空氣的溫濕度、潔凈度和空氣品質(zhì)問題越來越重視。隨著我國國民經(jīng)濟(jì)水平的不斷提高,建筑業(yè)也在持續(xù)穩(wěn)定地向前發(fā)展。 管道的防腐 60結(jié) 論 61參考文獻(xiàn) 62致 謝 63附 表 64附表一 冷負(fù)荷匯總表 64附表二 熱負(fù)荷匯總表 66附表三 濕負(fù)荷匯總表 67附錄四 新風(fēng)負(fù)荷 70附表五 設(shè)備選型表 72附表六 風(fēng)口選型 74外文資料 77 前 言 大學(xué)四年以來,從基礎(chǔ)課開始,我經(jīng)歷了從專業(yè)基礎(chǔ)課到專業(yè)課的系統(tǒng)理論學(xué)習(xí),同時從一個本專業(yè)的門外漢逐步向掌握基本專業(yè)理論知識的現(xiàn)代技術(shù)型人員邁進(jìn)。 空調(diào)系統(tǒng)的減振 57第10章 管道的保溫、防腐措施 59167。 水泵的選擇 52第9章 空調(diào)系統(tǒng)的消聲、減振措施 56167。 冷卻塔的選擇 51167。 44第8章 其它設(shè)備的選擇 50167。 氣流組織設(shè)計(jì)算 33第7章 水力計(jì)算 39167。 32167。 換熱器的選擇 30167。 新風(fēng)機(jī)組選型 28167。 空調(diào)系統(tǒng)的運(yùn)行調(diào)節(jié) 26第5章 空調(diào)設(shè)備的選擇 28167。 新風(fēng)量的確定 25167。 全空氣一次回風(fēng)系統(tǒng) 21167。 空調(diào)系統(tǒng)的劃分原則 16167。 冬季熱負(fù)荷的計(jì)算 12167。 設(shè)計(jì)參數(shù) 4第2章 負(fù)荷的計(jì)算 6167。 project is the hotel airconditioning engineering design .The hotel is a prehensive building, The total building area is 9120㎡,but the airconditioning area is 8973㎡.There are 10 floors of the building . The first floor is for shops which height of the first floor is about layers of the building is meters hight .The second and third layers is for Blair and the multifunction the remaining 410 layers is for office room and guest room.Combine the characteristics of the construction .In summer, we use watercooled chillers as a cold source . In winter,we use hot water pipe network of city as a source . In order to savings the operating cost. For accor and the standards room, such as small space we use the fan coil and new wind systems, There is one new air unit each layers so that fresh air can be into the indoor and fancoil bears the indoor cooling load . Fancoil and fresh air independent supply into room. As for the multifunction hall and shops, such as larger room, more staff, allowed temperature and humidity fluctuations in little,if you set the fancoil water system will use more end equipments, resulting in a waste of investment. So the entire air system to be adopted. Because of the different types of hotel rooms, the room is not the same as hot and cold load can be individual rooms regulation. The design of air conditioning water systems use closed, vertical different way, the level of the same programs, dual control, singlestage pumps, variable flow system. Airconditioning water system that is simple in structure, the initial investment, not easy to have a pipeline dirt and corrosion, the system does not need to overe the hydrostatic pressure head, water pumps, small power consumption and so on.KEY WORDS: airconditioning systems, cooling load,water System, independent of fresh air system, fan coil目 錄前 言 1第1章 工程概況 2167。本設(shè)計(jì)空調(diào)水系統(tǒng)選擇閉式、豎直異程、水平同程式、雙管制、單級泵,變流量系統(tǒng),這種空調(diào)水系統(tǒng)具有結(jié)構(gòu)簡單,初期投資小,管路不易產(chǎn)生污垢和腐蝕,不需要克服系統(tǒng)靜水壓頭,水泵耗電較小等優(yōu)點(diǎn)。而對于多功能廳、商鋪等空間較大、人員較多、溫度和濕度允許值波動范圍小的房間,采用全空氣系統(tǒng)。對于雅間、標(biāo)準(zhǔn)間等小空間采用風(fēng)機(jī)盤管加新風(fēng)系統(tǒng),每層設(shè)有新風(fēng)機(jī)組,可以由同層的新風(fēng)機(jī)組送入室內(nèi),風(fēng)機(jī)盤管獨(dú)立承擔(dān)室內(nèi)的冷熱負(fù)荷。酒店主樓地面10層,其中一層為商鋪,二、三層為雅間、多功能廳, ,其余四到十層為辦公室、標(biāo)準(zhǔn)間。西安龍泉大酒店空調(diào)工程設(shè)計(jì)摘 要暖通空調(diào)設(shè)計(jì)主要是對室內(nèi)熱環(huán)境、空氣品質(zhì)進(jìn)行設(shè)計(jì),但這必須在充分了解建筑對暖通空調(diào)的要求和暖通空調(diào)系統(tǒng)及設(shè)備對建筑及其它設(shè)施的影響的基礎(chǔ)上進(jìn)行設(shè)計(jì)。該建筑位于西安市,本工程為酒店空調(diào)工程設(shè)計(jì),酒店高約33米,是一座綜合性建筑物,總建筑面積為9120㎡,其中空調(diào)面積為8973㎡。結(jié)合建筑的特點(diǎn),夏天采用螺桿式冷水機(jī)組作為冷源,冬季采用城市供熱管網(wǎng)通過換熱器得到熱水,以達(dá)到節(jié)約運(yùn)行成本的目的。風(fēng)機(jī)盤管的新風(fēng)供給方式用單設(shè)新風(fēng)系統(tǒng),獨(dú)立供給室內(nèi)。因?yàn)樵摼频攴块g類型繁多,各房間冷熱負(fù)荷并不相同,可以個房間進(jìn)行個別的調(diào)節(jié)。關(guān)鍵詞:空調(diào)系統(tǒng),冷負(fù)荷,水系統(tǒng),獨(dú)立新風(fēng)系統(tǒng),風(fēng)機(jī)盤管THE DESIGN OF AIRCONDITIONING ENGINEERING FOR LONGQUAN HOTEL IN XIAN CITYABSTRACTHVAC design is mainly for indoor thermal environment, air quality in design, but construction must be fully aware of the requirements for HVAC and HVAC systems and equipment for construction and other facilities on the basis of design. The building is located in xi39。 原始資料 2167。 夏季冷負(fù)荷的計(jì)算 6167。 房間散濕量 14第3章 空調(diào)系統(tǒng)的方案確 16167。 方案的確定 19第4章 風(fēng)量的計(jì)算 21167。 風(fēng)機(jī)盤管加新風(fēng) 23167。 新風(fēng)負(fù)荷 25167。 風(fēng)機(jī)盤管 28167。 空調(diào)機(jī)組選型 29167。 冷水機(jī)組的選擇 30第6章 氣流組織計(jì)算 32167。 風(fēng)口型式的確定 32167。 水管水力計(jì)算 39167。 分水器與集水器的選擇 50167。 系統(tǒng)定壓方式 51167。 空調(diào)系統(tǒng)的消聲 56167。 管道的保溫 59167。為了檢驗(yàn)四年來的所學(xué)理論知識和