【正文】
[CR][ETX]E5[CR][LF] CS800 [ACK] HOST [STX] 2P|1|||||||||||||^[CR][ETX]E9[CR][LF] CS800 [ACK] HOST [STX] 3O|1|1281234^2^1^2^N||^^^ALT|R|20200119100425|||||||| |1||||||||||O[CR][ETX]2E[CR][LF] CS800 [ACK] HOST [STX] 4O|2|1281234^2^1^2^N||^^^ALB|R|20200119100425|||||||| |1||||||||||O[CR][ETX]1E[CR][LF] CS800 [ACK] HOST [STX] 5L|1|N[CR][ETX]08[CR][LF] CS800 [ACK] HOST [EOT] HOST [STX] 1H|\^amp。[CR][ETX]E5[CR][LF] CS800 [ACK] HOST [STX] 2P|1|||||||||||||^[CR][ETX]E9[CR][LF] CS800 [ACK] HOST [STX] 3O|1|3977777^4^1^1^N||^^^AST|R|20200119100534|||||||| |1||||||||||O[CR][ETX]51[CR][LF] CS800 [ACK] HOST [STX] 4O|2|3977777^4^1^1^N||^^^TP|R|20200119100534|||||||| |1||||||||||O[CR][ETX]0F[CR][LF] CS800 [ACK] HOST [STX] 5O|3|3977777^4^1^1^N||^^^ALB|R|20200119100534|||||||| |1||||||||||O[CR][ETX]3C[CR][LF] CS800 [ACK] HOST [STX] 6L|1|N[CR][ETX]09[CR][LF] CS800 [ACK] HOST [EOT] Batch: HOST [ENQ] CS800 [ACK] HOST [STX] 1H|\^amp。|||CS800|||||Host||1|20200119131335[CR] [ETX]25[CR][LF] HOST [ACK] CS800 [STX] 2Q|1|^130^5^45^N||ALL||||||||O[CR][ETX]B4[CR][LF] HOST [ACK] CS800 [STX] 3L|1|N[CR][ETX]06[CR][LF] HOST [ACK] CS800 [EOT] Batch: CS800 [ENQ] HOST [ACK] CS800 [STX]1H|\^amp。? 4 Y Patient Information Record (P) Description: This record is used to transfer patient sex and age to the analyzer (within test selection message). Example: STXFNP|1||123456||ZhangDongdong|||M||||||40^YCRETX[Checksum] CRLF Field No. E1394 ASTM Field Name Field Contents Max Length Mandatory 1 Record Type ID ?P? 1 Y 2 Sequence Number 6 Y 4 Laboratory Assigned Patient ID Sample ID or Sample No. 22 N 6 Patient Name 30 N 9 Patient Sex ?M?, ?F? or ?U? 1 N 15^1 Special Field 1 Age (1200) 3 N 15^2 Age Unit (?Y?,?M?,?D?) 1 Test Order Record (O) Description: This record holds information regarding analysis request and sample information to the analyzer (within test selection message). Example: S. No Mode: STXFNO|1|^1^1^10^N||^^^ALT|R|20202024151012|||||||||1||||||||||OCRETXCheckNumCRLF Sample ID Mode: STXFNO|1|AB2202022318^^1^10^N||^^^ALT|R|20202024151012|||||||||1||||||||||OCRETXCheckNumCRLF Field No. E1394 ASTM Field Name Valid Contents Max Length Mandatory 1 Record Type ID ?O? 1 Y 2 Sequence Number 6 Y 3^1 Specimen ID (Sample ID^ Sample No^ Disk ID^ Position No^ Diluent) Sample ID (ID Mode) 22 Y 3^2 Sample No. (S. No. Mode) 6 3^3 Disk ID 1 3^4 Position No. 2 3^5 ?Y? or ?N? 1 5 Universal Test ID 10 Y 6 Priority ?S? or ?R? 1 N 7 Requested/Ordered Date and Time ?YYYYMMDD HHMMSS? 14 N 16 Specimen Descriptor 1 Serum 2 Urine 3 CSF 4 Suprnt 5 Others 1 N 26 Report Types ‘ O’ , ‘ F’ , ‘ I’ , ‘ C’ or ?X? 1 N Message Terminator Record Description The Message Terminator Record to the analyzer is used with the Message Header Record to encapsulate related patient information. Example: STXFNL|1|NCRETXCheckNumCRLF Field No. E1394 ASTM Field Name Field Contents Max Length Mandatory 1 Record Type ID ?L? 1 Y 2 Sequence Number 6 Y 3 Termination Code ?N? or ?I? 1 Y notice: When the double direction munication apply the testing from the CS800 To Lis system, If when the lis system didn?f find the sample that should be applied,must be send: ENQ