【正文】
● continue to strengthen the power grid to improve the power system peak load record highs。 s power industry achievementsNational Congress, the power industry in the CPC Central Committee, under the correct leadership of the State Council, adhere to the guidance of scientific concept of development, and actively respond to the rapid growth of electricity demand challenges, seize the historical opportunity for development to accelerate the pace of structural adjustment and deepen the reform of electricity conscientiously fulfill their social responsibilities and promote the building of a harmonious society, the pace of development significantly accelerated the development of improved quality. Services to the party and the overall situation of the government work, economic and social development services, services of electricity customers the ability to further enhance and protect the economic and social development and people39。沒有他們的教育,今天的畢業(yè)論文也不可能順利完成。致 謝經(jīng)過一學(xué)期忙碌的學(xué)習(xí)工作,畢業(yè)設(shè)計(jì)終于即將完成,從一開始的略懂到現(xiàn)在的熟知,光憑我自己的努力是不可能完成的,在這過程中有老師的悉心指導(dǎo),還有同學(xué)的熱心幫助,這篇文章才得以順利完成。人工接地網(wǎng)的外緣應(yīng)閉合, 外緣各角應(yīng)做成圓弧形。垂直接地體間距取6~7m,沿閉合環(huán)路垂直打入地中,上端用扁鋼連接,~。(2)任意形狀復(fù)合接地網(wǎng)接地電阻通用計(jì)算公式。接地極與土壤間的接觸電阻:其值占接地電阻的20%~60%。m)其沖擊電阻應(yīng)滿足: Rch≤10Ω ()但在高土壤電阻率地區(qū),接地電阻達(dá)到要求值很有困難,允許采用較高電阻值,但必須滿足:獨(dú)立避雷針與電氣裝置帶電部分及電氣設(shè)備接地部分和構(gòu)架接地部分的空間距離為: Sk≤+ () 同時(shí),獨(dú)立避雷針的集中接地體與變電站接地網(wǎng)之間的地中距離應(yīng)為: Sd≤ ()兩式中,Rch—防雷電過電壓的沖擊接地電阻值Sk—防雷電反擊的空間距離Sd—防雷電反擊的地中距離h—避雷針上用來校驗(yàn)反擊的高度2. 變電站主接地網(wǎng)的均壓要求及計(jì)算變電站接地裝置型式及布置的確定,應(yīng)從人身及設(shè)備安全考慮,以降低接觸電壓和跨步電壓為目的,并符合我國接地設(shè)計(jì)規(guī)范要求。② 在中性點(diǎn)不接地、經(jīng)消弧線圈接地的變電站中,保護(hù)接地電阻應(yīng)符合如下要求。網(wǎng)內(nèi)敷設(shè)的均壓帶間距一般取3~10m,可以等間距布置,也可以不等間距布置,但應(yīng)按一定規(guī)律變化。變電站的接地裝置要充分利用自然接地體,若自然接地體滿足不了接地電阻值要求,則要加設(shè)人工接地體,而且多數(shù)是敷設(shè)以水平接地體為主的人工接地體。 變電站的接地設(shè)計(jì) 變電站接地裝置的型式在變電站集中安裝了最重要的電氣設(shè)備和電氣裝置,如變壓器、斷路器及各種控制屏、保護(hù)柜等。 進(jìn)線保護(hù)段接線設(shè)計(jì) 35KV進(jìn)線保護(hù)段接線圖架設(shè)避雷線的線段稱為進(jìn)線保護(hù)段,其長度一般為1~2km,具有較高的耐雷性能。具體是雷電壓在線路上感應(yīng)產(chǎn)生的地點(diǎn)離變電站愈遠(yuǎn),它流動到變電站時(shí)的損耗就愈大,其波陡度和幅值就降得愈低。同時(shí),應(yīng)限制流過避雷器的雷電流的大小,以降低殘壓,尤其不能超過避雷器的額定通流能力,否則避雷器就會燒壞。2. 避雷器與變壓器的最大電氣距離35KV變壓器允許的距離lmax 因?yàn)?5KV進(jìn)線為1條:根據(jù)Um=Uc5+2al/v=Uc5+2a0l,令Um=Ubil(35KV變壓器的雷電沖擊耐受電壓為185kV,35KV進(jìn)線1km有避雷線,)。 在平常的設(shè)計(jì)要求中,根據(jù)上述公式,只要距離滿足要求即認(rèn)可,但是,隨著變電站設(shè)備的老化,其耐雷水平或承受過電壓的能力都會存在不同程度的下降,對變電站來說,最重要的設(shè)備是變壓器,其承受過電壓的能力相應(yīng)低于其他設(shè)備,因此,在電氣設(shè)備的絕緣配合中,通常應(yīng)以變壓器作為絕緣配合的核心,站內(nèi)母線避雷器的安裝,要盡可能做到與主變壓器之間的距離最短;在一些變電站, 比如10 kV (35kV) 母線避雷器與TV 安裝于同一間隔內(nèi),該間隔可以安裝于該母線段的任何位置,但從其與主變最小距離考慮,該間隔盡可能做到挨著主變側(cè)開關(guān)間隔安裝,在實(shí)際設(shè)計(jì)、施工中也是容易做到的,對保護(hù)變壓器側(cè)的絕緣是有好處的。在此稱為避雷器的防護(hù)距離?,F(xiàn)階段, 大部分變電站都采取使用氧化鋅避雷器代替原來的閥型避雷器。對于無間隙的金屬氧化物避雷器,基本技術(shù)要求則不同,它沒有滅弧問題,相應(yīng)的卻產(chǎn)生了獨(dú)特的熱穩(wěn)定性問題。(1) 具有良好的伏秒特性,以實(shí)現(xiàn)與被保護(hù)電氣設(shè)備絕緣的合理配合。(1)單根避雷線的保護(hù)范圍 如圖25所示。h/2hahABrx 單根避雷針的保護(hù)范圍由上圖有,在被保護(hù)高度為hx水平面上, 其保護(hù)半徑rx為 當(dāng)hk≥h/2時(shí) rx=(hhx)p ()當(dāng)hxh/2時(shí) rx=()p ()式中:p—考慮避雷針太高時(shí),保護(hù)半徑不成正比增大的系數(shù)。接地體是直接泄放雷電流的,所以其選用既要考慮經(jīng)濟(jì),又要滿足接地電阻值的規(guī)定要求。圓鋼直徑不得小于8~12mm;扁鋼截面不得小于12mm4mm。圓鋼直徑應(yīng)大于12~16mm;鋼管直徑應(yīng)大于20~25mm。 防雷裝置1. 避雷針避雷針是防直接雷擊的有效裝置。 盡管雷云有很高的初始電位(估可達(dá)幾百兆伏),可能使大氣擊穿,形成先導(dǎo)主放電,但是地而被擊物體的電位并不取決于這一初始電位,而是取決于雷電流與被擊物體阻抗的乘積(被擊物體阻抗是指被擊點(diǎn)與大地零電位參考點(diǎn)之間的阻抗)。雷電放電是一種氣體放電現(xiàn)象,由其引起的過電壓,叫做大氣過電壓。 其主要性能特點(diǎn)為: ,裝置的MCU均采用MOTOROLA的32位MCU芯片,硬件系統(tǒng)具有高的抗干擾能力及工作可靠性。由軟件可實(shí)現(xiàn)多種保護(hù)功能,可大大簡化裝置的硬件結(jié)構(gòu),可以在事故后打印出各種有用數(shù)據(jù)7)運(yùn)行維護(hù)工作量小,現(xiàn)場調(diào)試方便。而微機(jī)保護(hù)采用了大規(guī)模集成電路,器件性能穩(wěn)定,元件數(shù)目、連接線等都大大減少,因而可靠性高。2)綜合判斷能力強(qiáng)。6)補(bǔ)償電容器的失壓和過壓保護(hù):這兩種保護(hù)屬于技術(shù)性保護(hù),所有電容器組均應(yīng)裝設(shè)失壓和過壓保護(hù),過壓保護(hù)主要是防止電容器長期過電壓運(yùn)行;失壓保護(hù)主要是防止電容器失去電壓后在帶有電荷的情況下立即重合造成電容器損壞。4)自動重合閘裝置:電力系統(tǒng)中的不少故障特別是架空線路上的短路故障大多是暫時(shí)性的,這些故障在斷路器跳閘后,多數(shù)能很快地自行消除。3)線路單相接地保護(hù):在中性點(diǎn)不接地系統(tǒng)中,若發(fā)生單相接地故障時(shí),只有很小的接地電容電流,而相間電壓仍然是對稱的,因此可暫時(shí)繼續(xù)運(yùn)行。2)防止內(nèi)部故障及油面降低設(shè)置瓦斯保護(hù)。② 變壓器的內(nèi)部故障有相間短路、繞組的匝間短路和絕緣損壞。1) 本設(shè)計(jì)中的電力系統(tǒng)具有非直接接地的架空線路及中性點(diǎn)不接地的電力變壓器等主要設(shè)備。其特點(diǎn)是配裝的真空斷路器為中重式,即斷路器位于開關(guān)柜前柜的中部,因此下部空間節(jié)省下來可用于其它方案的擴(kuò)展或作為電纜室用。10KV進(jìn)線末端保護(hù)母線用電流互感器和上述情況基本相同,同選LQJ10,校驗(yàn)方法相同4.10KV配線處電流互感器(以通往電修車間的線路為例)1)≥==選LQJ10型電流互感器,選取一次側(cè)電流I1N=50A,10P級用于保護(hù)2)短路穩(wěn)定度校驗(yàn)LQJ10型電流互感器1s熱穩(wěn)定倍數(shù)和動穩(wěn)定倍數(shù)Krw=It/=90 () Kdw=imax/=225 () =22550=16KA≥ich(3)= ()所以動穩(wěn)定校驗(yàn)合格 ()2t=(900..05KA)2= ()Id(a)(3)2tjx= ()所以熱穩(wěn)定校驗(yàn)合格3)準(zhǔn)確度要求的二次回路阻抗校驗(yàn)準(zhǔn)確度等級為3級允許的額定二次回路阻抗Z2N=,Z2N>Z2,所以滿足測量精度要求。 2.變壓器二次側(cè)用于母線保護(hù)的電流互感器1)≥(B)== 選LQJ10型電流互感器,選取一次側(cè)電流I1N=400A,10P級用于保護(hù)2)短路穩(wěn)定度校驗(yàn)LQJ10型電流互感器1s熱穩(wěn)定倍數(shù)和動穩(wěn)定倍數(shù)Krw=It/=75 () Kdw=imax/=160 () =160400=≥ich(2)(3)= ()所以動穩(wěn)定校驗(yàn)合格()2t=(75)2=900 ()Id(2)(3)2tjx=(++)= ()所以熱穩(wěn)定校驗(yàn)合格3)準(zhǔn)確度要求的二次回路阻抗校驗(yàn)準(zhǔn)確度等級為3級允許的額定二次回路阻抗Z2N=,Z2N>Z2,所以滿足測量精度要求。n2)=(100/)= (4,11) 電纜線路L14電抗標(biāo)幺值 X*L14=X0L14(Sjz/U2pjA,Ujz1=37KV,Ujz2= () 式中:Sjz—基準(zhǔn)容量,Ujz—基準(zhǔn)電壓(2)計(jì)算系統(tǒng)各元件阻抗標(biāo)幺值,繪制等效電路圖 最大運(yùn)行方式及最小運(yùn)行方式下系統(tǒng)電抗標(biāo)幺值分別為 X*1max=Sjz/Sd﹒max=100/400=,X*1min=Sjz/Sd﹒min=100/200= () 式中:Sd﹒max、Sd﹒min—系統(tǒng)最大,最小運(yùn)行方式下的短路容量 架空線L1電抗標(biāo)幺值為 X*L1=X0L1(Sjz/U2pj 短路電流的計(jì)算 線路選擇1)35KV送電線 35KV及以上電壓等級的送電線路,首先應(yīng)按經(jīng)濟(jì)電流密度選擇導(dǎo)線截面,再按允許載流量和機(jī)械強(qiáng)度條件校驗(yàn) ① 選擇經(jīng)濟(jì)截面 導(dǎo)線材料選擇:鋁;年最大負(fù)荷利用小時(shí)數(shù)Tmax:2300h〈3000h所以選擇導(dǎo)線的經(jīng)濟(jì)電流密度Jec= 導(dǎo)線的經(jīng)濟(jì)截面: Aec=I30(A)/Jec= () (按經(jīng)濟(jì)電流密度Jec選擇導(dǎo)線截面時(shí),一般應(yīng)盡量取接近且小于Aec的標(biāo)準(zhǔn)截面,這是從節(jié)約投資和有色金屬方面考慮的)選標(biāo)準(zhǔn)截面為35mm2,即選LGJ―35型鋼芯鋁絞線 ② 校驗(yàn)發(fā)熱條件LGJ―35型允許載流量(室外20176。在等效電路圖上,只需將被計(jì)算的短路電流所流經(jīng)的一些主要元件表示出來,并標(biāo)明其序號和阻抗值,然后將等效電路化簡。進(jìn)行短路電流計(jì)算,首先要繪制計(jì)算電路圖。由于鍋爐房供生產(chǎn)用高壓蒸汽,停電會使鍋爐發(fā)生危險(xiǎn)。母線制有單母線制和雙母線制,其中的母線又有母線分段及母線不分段兩種接線方式。 本鋼鐵企業(yè)變電所的電氣主接線設(shè)計(jì) 母線母線是指在變電所中各級電壓配電裝置的連接,以及變壓器等電氣設(shè)備和相應(yīng)配電裝置的連接,大都采用矩形或圓形截面的裸導(dǎo)線或絞線,這統(tǒng)稱為母線。同時(shí)設(shè)計(jì)主接線時(shí)應(yīng)留有發(fā)展擴(kuò)建的 余地。 變電所電氣主接線設(shè)計(jì)應(yīng)滿足如下基本要求:1 可靠性:供電可靠性是電力生產(chǎn)和分配的首要要求, 停電會對 國民經(jīng)濟(jì)各部門帶來巨大的損失, 往往比少發(fā)電能的損失 大幾十倍, 導(dǎo)致產(chǎn)品報(bào)廢、 設(shè)備損壞、 人身傷亡等。A,所以所選變壓器的容量為5000KV對供有大量一二級負(fù)荷的變電所,應(yīng)采用兩臺變壓器,以便一臺變壓器發(fā)生故障和檢修時(shí),另一臺變壓器能對一二級負(fù)荷繼續(xù)供電;對只有二級負(fù)荷而無一級負(fù)荷的變電所,可采用一臺變壓器,但須自備備用電源,本設(shè)計(jì)即采用后一種方案。(2)地質(zhì)水文資料,平均海拔,地層以砂粘土為主,地下水位。供電電源條件當(dāng)?shù)毓╇姴块T可提供兩個(gè)供電電源,供設(shè)計(jì)部門選定:(1)待設(shè)計(jì)總降壓變電所的主電源由上一級某區(qū)域變電站()提供電源,架空線引入,作為工作電源進(jìn)線,此站距企業(yè)南側(cè)。根據(jù)當(dāng)?shù)仉娋W(wǎng)的供電電壓等級,同時(shí)考慮用電設(shè)備的負(fù)荷容量和供電距離等因素,與電力部門協(xié)商確定供電電壓為。而且該廠距離市區(qū)較遠(yuǎn),消防用水需廠方自備。 2)國標(biāo)GB5006292《電力裝置的繼電保護(hù)和自動裝置設(shè)計(jì)規(guī)范》3)《工業(yè)企業(yè)供電》 設(shè)計(jì)原始資料本企業(yè)共有12個(gè)車間,承擔(dān)各附屬廠的設(shè)備、變壓器修理