freepeople性欧美熟妇, 色戒完整版无删减158分钟hd, 无码精品国产vα在线观看DVD, 丰满少妇伦精品无码专区在线观看,艾栗栗与纹身男宾馆3p50分钟,国产AV片在线观看,黑人与美女高潮,18岁女RAPPERDISSSUBS,国产手机在机看影片

正文內(nèi)容

武警深圳支隊(duì)梅林警備指揮部辦公、營房樓工程施工組織設(shè)計(jì)(108頁)-工程設(shè)計(jì)-資料下載頁

2025-08-04 12:08本頁面

【導(dǎo)讀】1.1編制說明·····································································1. 1.2編制依據(jù)·····································································2. 2.1.工程概況····································································3. 2.2本工程承包的范圍·························································7. 3.1施工指導(dǎo)思想·······························································8. 3.2施工管理組織機(jī)構(gòu)·························································9. 4.1施工總平面布置原則·····················································12. 4.2施工平面布置····································&#183

  

【正文】 樣品經(jīng)甲方、監(jiān)理認(rèn)可后方可訂貨采購。 對于用于工程的主要建筑材料,進(jìn)場時(shí)必須具備正式的出場合格證和材質(zhì)化驗(yàn)單,同時(shí)對鋼材、水泥等及時(shí)進(jìn)行抽樣送檢,只有當(dāng)送檢合格后方可用于施工。 對進(jìn)口材料、設(shè)備應(yīng)合同商檢局檢驗(yàn)。 對甲供材料,同樣按以上辦法嚴(yán)格控制。 無論是甲供還是自購材料,如不合格,堅(jiān)決退貨。 在材料采購和使用過程中,必須做到“四驗(yàn)”、“三把關(guān)”,即“驗(yàn)規(guī)格、驗(yàn)品種、驗(yàn)數(shù)量、驗(yàn)質(zhì)量”、“材料驗(yàn)收人員把關(guān)、材料質(zhì)量試驗(yàn)人員把關(guān)、操作人員把關(guān)”,以確保用于本工程的所有材料均是合格優(yōu)質(zhì)的材料。 械設(shè)備的控制 機(jī)械設(shè)備的選擇應(yīng)本著因地制宜、因工程制宜,按照技術(shù)上先進(jìn)、經(jīng)濟(jì)上合理、生產(chǎn)上適用、性能上可靠、使用上安全、操作上方便和維修方便等原則,使之合格裝備、配套使用、有機(jī)聯(lián)系,以充分發(fā)揮建筑機(jī)械性能,力求獲得較好的綜合經(jīng)濟(jì)效益。 在施工機(jī)械設(shè)備進(jìn)場 前必須進(jìn)行一次全面的檢查保養(yǎng),使機(jī)械設(shè)備在投入使用前達(dá)到最佳狀態(tài),達(dá)到完好機(jī)械的標(biāo)準(zhǔn)。 在施工中按照本單位機(jī)械設(shè)備維修保養(yǎng)規(guī)定,制定機(jī)械設(shè)備維修保養(yǎng)計(jì)劃,以保證在施工過程中所有的機(jī)械設(shè)備處于最佳狀態(tài)。 合理地使用機(jī)械設(shè)備,正確操作。這是保證施工質(zhì)量的重要環(huán)節(jié),實(shí)行定機(jī)、定人、定崗位責(zé)任的“三定”制度。操作人員必須認(rèn)真執(zhí)行各項(xiàng)規(guī)章制度,嚴(yán)格遵守操作規(guī)程,防止出現(xiàn)安全質(zhì)量事故。施工機(jī)械、電梯、井架卷揚(yáng)機(jī)等操作人員應(yīng)持證上崗。機(jī)械設(shè)備的保證安全裝置要齊全可靠,要經(jīng)常檢查、保養(yǎng)、維修,使其運(yùn)轉(zhuǎn)靈活。操作時(shí),不準(zhǔn)機(jī)械 帶病工作、不準(zhǔn)超載、超負(fù)荷運(yùn)行。 施工方法及施工環(huán)境因素的控制 施工方案、施工方法的正確與否,是直接影響工程項(xiàng)目的質(zhì)量、進(jìn)度、投資三大目標(biāo)能否順利實(shí)現(xiàn)的關(guān)鍵。必須結(jié)合工程實(shí)際和本工 程特點(diǎn),從技術(shù)、組織、管理、經(jīng)濟(jì)等方面進(jìn)行全面分析、綜合考慮,確保施工方案、施工方法在技術(shù)上可行,在經(jīng)濟(jì)上合理,有利于提高工程質(zhì)量。 影響工程質(zhì)量的環(huán)境因素較多,且具有復(fù)雜多變的特點(diǎn)。根據(jù)本工程特點(diǎn)和具體條件,重點(diǎn)對工程技術(shù)環(huán)境、工程管理環(huán)境、勞動環(huán)境采取有效的措施嚴(yán)加控制。 施工中計(jì)量檢測設(shè)備的保證措 施 計(jì)量檢測設(shè)備在整個(gè)質(zhì)量控制中是一個(gè)重要的環(huán)節(jié),在計(jì)量工作中,我們將加強(qiáng)各種計(jì)量設(shè)備的檢測工作,并在深圳市指定權(quán)威的計(jì)量工具檢測機(jī)構(gòu)檢測校驗(yàn),按我單位的計(jì)量設(shè)備管理程序文件進(jìn)行周檢管理,確保工程中使用的計(jì)量檢測設(shè)備處于完好、準(zhǔn)確狀態(tài),從而確保工程的施工質(zhì)量。 關(guān)鍵工序的技術(shù)措施 各分項(xiàng)工程的具體操作方法、操作要點(diǎn)、注意事項(xiàng)、質(zhì)量要求等詳見我公司的作業(yè)指導(dǎo)書。嚴(yán)格按作業(yè)指導(dǎo)書進(jìn)行操作和檢查,才能保證各分部分項(xiàng)工程的施工質(zhì)量。 測量放線 設(shè)立專門的測量小組,測量儀器及工具事先檢查、定 期校正。 模板工程施工 ( 1)、工程技術(shù)人員在工序開工前向班組書面交底,工人按圖施工,質(zhì)檢員嚴(yán)格按圖檢查驗(yàn)收。 ( 2)、工序交接檢,當(dāng)鋼筋工程完工后應(yīng)組織鋼筋、模板工班組 長和技術(shù)員進(jìn)行現(xiàn)場交接檢,凡鋼筋位置不符合要求的必須整改完后方可封模。 ( 3)、提高模板施工質(zhì)量標(biāo)準(zhǔn),垂直平整度均要在規(guī)定范圍之內(nèi),這是影響工程質(zhì)量的一個(gè)重要因素。 ( 4)、模板拆模后要進(jìn)行清理修正,涂刷隔離劑后才能繼續(xù)使用。 ( 5)、證板縫能滿足優(yōu)良標(biāo)準(zhǔn)要求,在模板安裝畢后,應(yīng)用透明膠紙粘貼板縫。 鋼筋工程施工 1)鋼筋進(jìn)場后要及時(shí)進(jìn)行原材料檢測試驗(yàn),合格材料方可使用。 2)鋼筋工程施工前要認(rèn)真做好翻樣、交底工作。 3)鋼筋工程安裝后,工程質(zhì)檢人員應(yīng)對鋼筋進(jìn)行檢查,做好隱蔽驗(yàn)收。重點(diǎn)進(jìn)行下列內(nèi)容檢查。根據(jù)設(shè)計(jì)圖,檢查鋼筋的種類、直徑、根數(shù)、間距是否正確,綁扎是否牢固、有無松動脫變現(xiàn)象。 混凝土工程施工 1)嚴(yán)格執(zhí)行材料進(jìn)場驗(yàn)收制度,特別是對水泥要有計(jì)劃地提前做好化驗(yàn)工作,杜絕不經(jīng)化驗(yàn)而先使用的現(xiàn)象。 2)商品混凝土到現(xiàn)場后要有專職質(zhì)檢員進(jìn)行檢驗(yàn)。 3)作業(yè)面設(shè)技術(shù)人員和專職質(zhì)檢員跟班作業(yè),對振搗密實(shí)度、下料方法、平整度進(jìn)行監(jiān)督檢查,對不符合施工工藝標(biāo)準(zhǔn)的將行使質(zhì)量否決權(quán),有權(quán)下令停工修復(fù),直到符合工藝標(biāo)準(zhǔn)才能繼續(xù)施工。 、建筑物裂縫防治措施 經(jīng)過我司多年的施工經(jīng)驗(yàn)總結(jié),并結(jié)合本工程的實(shí)際情況,編制的如下建筑物防裂縫措施,其中諸多細(xì)節(jié)僅代表施工單位的意見和提議,在具體施工時(shí),我們將提請?jiān)O(shè)計(jì)院、建設(shè)單位、監(jiān)理單位等有關(guān)部門討論審核,并以工程技術(shù)核定的形式在征得以上各方一致認(rèn)可后進(jìn)行施工。 、結(jié)構(gòu)裂縫防治措施 (1)、地下室外墻 合理選擇、嚴(yán)格控制原材料質(zhì)量及優(yōu)化砼配合比。 水泥用中、低水化 熱、干縮小的品種,用粉煤灰硅酸鹽水泥,礦渣硅酸鹽水泥,其次用普通硅酸鹽水泥,不用硅酸鹽水泥,火山灰質(zhì)硅酸鹽水泥; 石子用連續(xù)級配Ⅱ區(qū)粒級,堅(jiān)固性良好的石子,針片狀含量15%,含泥量 1%,并不得超標(biāo); 砂用中、粗砂,堅(jiān)固性良好,細(xì)度模數(shù)大于 ,含泥量 3%,并不得超標(biāo),有害物質(zhì)含量應(yīng)符合規(guī)定; 摻加高效減水劑和適量粉煤灰優(yōu)化砼配合比,在滿足強(qiáng)度、抗?jié)B及和易性要求下,減少水泥用量,減少用水量,水灰比在 以內(nèi),坍落度在滿足泵送條件下,取坍落度下限。木模澆水濕潤,砼分層澆筑,振搗密實(shí),合理組織施工,禁 止產(chǎn)生冷縫,禁止用振搗棒驅(qū)趕砼澆筑,加強(qiáng)檢驗(yàn)砼坍落度,嚴(yán)禁在現(xiàn)場隨意加水。準(zhǔn)確控制拆模時(shí)間,外模和內(nèi)模應(yīng)協(xié)調(diào)拆模,不能只拆外模,不拆內(nèi)模,保證結(jié)構(gòu)變形一 致,地下室外墻帶模養(yǎng)護(hù)的時(shí)間不少于 14d。地下室外墻不宜暴露時(shí)間過長,應(yīng)及時(shí)做防水并回填土。 (2)、樓板 板角設(shè)雙層雙向加強(qiáng)鋼筋或設(shè)幅射筋。樓板開洞設(shè)加強(qiáng)筋,大洞口要用邊緣構(gòu)件 (小梁 )加強(qiáng)。 為保證板支座 (尤其是陽臺、雨蓬及檐口挑板 )負(fù)筋位置準(zhǔn)確,在板中布置一定數(shù)量的“馬蹬筋”。砼澆筑前,清除垃圾、泥土、油污,合理組織施工,禁止產(chǎn)生冷縫,施工縫嚴(yán)格按施工規(guī) 范處理,用平板振動器搗實(shí),板砼面采取刮平并二次抹壓密實(shí)。用麻袋或薄膜在 4~12h 內(nèi)用覆蓋法保溫保濕養(yǎng)護(hù),具體養(yǎng)護(hù)時(shí)間不少于 14d,不宜用澆水法養(yǎng)護(hù),掌握合適的拆模時(shí)間 (壓同等條件下現(xiàn)場養(yǎng)護(hù)的試塊確定 ),不得過早拆模,禁止過早上人 (未達(dá) 12N/mm2)或承受較大施工荷載。 (3)、梁 梁高超過 700,必須在梁兩側(cè)設(shè)腰筋,沿高度間距 200,直徑 10,梁下部鋼筋保護(hù)層應(yīng)控制準(zhǔn)確,不宜超厚,任何時(shí)候不得 40mm??缍?8m 的梁,砼達(dá) 100%強(qiáng)度才能拆模。 、建筑裂縫防治措施 砌體 (1)、材料要求 有關(guān)材料要求如下: 進(jìn)入現(xiàn)場的砌塊應(yīng)具有生產(chǎn)資格證 (或生產(chǎn)許可證 )、并按有關(guān)規(guī) 定要求有鑒證抽樣送檢,經(jīng)檢驗(yàn)合格后,方可使用。砌筑砂漿用的水泥應(yīng)有產(chǎn)品出廠檢驗(yàn)報(bào)告,并經(jīng)有鑒證送檢合格后,方可使用,不同品種水泥,不得混用。配制砂漿用砂采用中砂,并過篩,不得含草根、廢渣等雜物,含泥量 5%,并不得超標(biāo)。配制砂漿盡量摻外加劑和粉煤灰,其摻量由試驗(yàn)室經(jīng)試配確定。砌筑砂漿采用機(jī)械現(xiàn)場集中方式拌合,不宜用人工在砌筑點(diǎn)分散拌合,砂漿要求隨拌隨用。 (2)、建筑設(shè)計(jì) 門窗洞邊 200 內(nèi)的砌體用大于 M5 的砂漿或 C15 細(xì)石砼填實(shí)砌塊孔洞,窗臺處加設(shè)鋼筋砼窗臺板或窗臺下設(shè)水平鋼筋用 M10 水泥砂漿抹平至設(shè)計(jì)標(biāo)高,門窗頂如有砌體,應(yīng)加設(shè)過梁 (鋼筋砼過梁 ),若過梁端部與砼柱、墻直接相接,應(yīng)設(shè)角鋼支座支承過梁。砌體內(nèi)設(shè)置的暗管、暗線、暗盒、洞口、溝槽應(yīng)考慮避免打洞鑿槽,施工中先施工管線盒等,后砌體埋入管盒的方法,或采取在填充墻上設(shè)鋼筋砼柱、梁的方式埋入管線,在已砌墻體上開槽,應(yīng)用專用的鏤槽工具或用切割機(jī)開槽,禁止人工鑿打。砌體墻與砼柱、墻應(yīng)拉結(jié)牢固,沿柱或墻高度每 600(或符合砌塊模數(shù) )預(yù)留 2?6 拉結(jié)鋼筋,伸入墻內(nèi) 600,預(yù)留 拉結(jié)筋有四種方法: a、預(yù)埋鐵腳法; b 預(yù)留鋼筋法; c、脹錨螺栓加鋼板法; d、貼模筋法。砌體墻長度 5m,加構(gòu)造柱,高度 4m,加圈梁,墻體與梁、板、柱結(jié)合處的扶灰層中,沿縫長方向加寬 200的鋼網(wǎng)作防裂處理,并繃緊釘牢。在鋼筋砼屋面上設(shè)置保溫層或隔熱層,并在結(jié)構(gòu)封頂后,及時(shí)施工保溫、隔熱層,不宜暴露時(shí)間過長。這是防止頂層砌體墻開裂多現(xiàn)象的有效措施,屋頂女兒墻不宜采用砌 墻,應(yīng)采用鋼筋砼女兒墻,屋面剛性層不應(yīng)頂緊女兒墻,兩者間應(yīng)留設(shè)伸縮縫,防止屋面剛性層伸縮使女兒墻跟部產(chǎn)生裂縫。 (3)、砌體施工 砌筑時(shí)應(yīng)控制砌 塊含水率,紅磚為 10~ 15%,砼空心砌塊為 5~8%,雨天施工須防止雨水直接沖淋砌體,不得使用被雨水濕透的砌塊,墻體材料宜保持均一性。砌筑時(shí)清掃墻體下樓面,不得有雜物,并濕潤滿鋪底灰,砌塊須錯縫砌筑,上下皮搭接長度不宜小于 90mm 或砌塊長度的 1/3,否則在灰縫中設(shè)拉結(jié)筋 (網(wǎng) ),鋪灰后立即放砌塊,用木錘敲擊擺正,如砌后需移動砌塊,須鏟除原有砂漿重砌,不得隨意撬動已砌好的砌塊或打洞鑿槽,切鋸砌塊用專用工具,不得用瓦刀砍劈,否則砌塊會缺梭掉角?;铱p要求橫平豎直,砂漿飽滿,水平縫不低于 90%,豎縫不低于 70%,豎縫宜 用內(nèi)外臨時(shí)夾板灌縫,嚴(yán)禁干砌再水沖灌縫,邊筑邊勾縫,不得出現(xiàn)暗縫,嚴(yán)禁有透亮縫,灰縫厚度應(yīng)均勻,控制在 812mm。日砌高度控制在 ,最上二皮應(yīng)隔日砌筑,待下部砌體變形沉實(shí)穩(wěn)定后再砌,最上一皮用輔助實(shí)心小砌塊 (或紅磚 )45?斜砌擠緊砼梁板底,空隙用砂漿填實(shí),墻體留槎應(yīng)留斜搓,如留直搓,沿高度 600 設(shè)置 2?6 拉結(jié)鋼筋伸入墻內(nèi) 600,并留成“馬牙搓”。 墻體抹灰 抹灰用的砂用中砂,使用前過篩,含泥量 5%;抹灰砂漿應(yīng)具有良好和易性,并有一定粘結(jié)強(qiáng)度,其保水性即分層度為 1~ 2cm,過低過高均 不合要求。抹灰砂漿品種按設(shè)計(jì)要求選用,并符合下列規(guī)定: 墻體抹灰在基體或基層的質(zhì)量檢驗(yàn)驗(yàn)收合格后施工。其中砌塊要砌完至少 7d 后才可進(jìn)行抹灰。抹灰前清除基層浮灰,處理干凈,結(jié)構(gòu)偏差大的部位用與底層抹灰相同的砂漿填補(bǔ)密實(shí),埋設(shè)暗線、暗盒等孔槽處,先用水泥砂漿填實(shí)、補(bǔ)平,并用鋼網(wǎng)作防裂處理,不同材料相接處基體表面應(yīng)先鋪釘 200 寬鋼網(wǎng),并繃緊牢固,釘?shù)拈g距不能過大,保證鋼網(wǎng)不變形起拱。沖筋、做灰餅的砂漿與底層抹灰砂漿相同,防止收縮不一致開裂。抹灰分層進(jìn)行,一次抹灰絕對不能過厚,多層抹灰間隔時(shí)間絕對不能過短,跟的太緊 ,這是防止砂漿收縮率大而開裂空鼓的有效措施。抹灰厚度控制為:水泥砂漿每遍 5~ 7mm;混合砂漿每遍 7~ 9mm;面層厚度為 2~ 5mm。 水泥砂漿面層不能用撤干水泥粉或用純水泥漿壓光,應(yīng)用面層原漿收光,以免龜裂。各層抹灰砂漿配合比不能相差太大,底層砂漿與中層砂漿配合比應(yīng)基本相同,中層不能高于底層,底層不能高于基層,以免在凝結(jié)過程中產(chǎn)生強(qiáng)度差的收縮應(yīng)力造成開裂空鼓。門窗框塞縫作為一道主工序由專人負(fù)責(zé)用小鎦子將縫隙全部塞嚴(yán)。抹灰完后澆水在濕潤條件下養(yǎng)護(hù) 7d,各種砂漿抹灰層在凝結(jié)前,應(yīng)防止快干、水沖、撞擊和振動,凝結(jié)后 ,防止污染和損壞,要避免日光爆曬下抹灰,要有防曬,防雨水沖刷的措施。對長度較長,層高較高的墻面抹灰,采用以縫制縫的方法做控制縫防裂,在抹灰層完成凝結(jié)后 (一般第二天 ),彈線用切割機(jī)按 3m 3m 間距切縫,這是防止墻體抹灰層開裂,主動控制裂縫的有效措施。 7 確保安全生產(chǎn)的技術(shù)組織措施 安全生產(chǎn)總目標(biāo) 本工程施工安全生產(chǎn)總目標(biāo)為:杜絕重大傷亡事故、輕傷安全事故控制在 ?以內(nèi),實(shí)現(xiàn)“五無”(即無重傷、無死亡、無倒塌、無中毒、無火災(zāi));無機(jī)械設(shè)備事故;無汽車、裝載機(jī)等行車事故。堅(jiān)持貫徹“安全第一,預(yù)防為主 ”的方針。 安全生產(chǎn)保證措施 、施工安全生產(chǎn)管理措施 健全安全機(jī)構(gòu),明確工地及各分區(qū)、各工種的安全責(zé)任人,建立領(lǐng)導(dǎo)安全值班制度,做好值班記錄,發(fā)現(xiàn)問題及時(shí)整改。 建立以項(xiàng)目經(jīng)理為組長,項(xiàng)目副經(jīng)理、技術(shù)負(fù)責(zé)人、安全總監(jiān)為副組長,專業(yè)工長和班組長為組員的項(xiàng)目安全生產(chǎn)領(lǐng)導(dǎo)小組,在項(xiàng)目形成縱橫網(wǎng)絡(luò)管理體制。各自職責(zé)如下: (1)、項(xiàng)目經(jīng)理:全面負(fù)責(zé)施工現(xiàn)場的安全措施、安全生產(chǎn)等,保證施工現(xiàn)場的安全。 (2)、項(xiàng)目副經(jīng)理:直接對安全生產(chǎn)負(fù)責(zé),督促、安排各項(xiàng)安全工作,并隨時(shí)檢查。 (3)、技術(shù)負(fù)責(zé)人:制定項(xiàng)目安全技術(shù)措施和分項(xiàng)安全方案,督促安全措施落實(shí),解決施工過程中不安全的技術(shù)問題。 (4)、安全員:督促施工全過程的安全生產(chǎn),糾正違章,配合有關(guān)部門排除施工不安全因素,進(jìn)行安全技術(shù)書面交底,安排項(xiàng)目內(nèi)安全活動及安全教育的開展,監(jiān)督勞防用品的發(fā)放和使用。 (5)、施工工長:負(fù)責(zé)上級安排的安全工作的實(shí)施,進(jìn)行施工前 安全交底工作,監(jiān)督并參與班組的安全學(xué)習(xí)。 ( 6)、人員管理: 加強(qiáng)現(xiàn)場管理人員的安全意識使每一個(gè)管理人員做到關(guān)心安全工作并在實(shí)際的管理工作中注意安全生產(chǎn)的兼顧。嚴(yán)格執(zhí)行工地三 級安全教育和交底制度(即進(jìn)場時(shí)、上崗前、專業(yè)工種),未經(jīng)教育和交底的人員不準(zhǔn)上崗作業(yè)。教育職工由“要我安全”變?yōu)椤拔乙踩?,特殊工種(如電工、焊工、機(jī)械工等)必須持證上崗,不準(zhǔn)隨便用人。 ( 7)、建立健全各種規(guī)章制度,把安全生產(chǎn)和經(jīng)濟(jì)效益掛起鉤來,做到獎罰分明。 施工安全生產(chǎn)技術(shù)措施 (1)在編制施工組織設(shè)計(jì)和分項(xiàng)施工方案中都要有針對性安全技術(shù)措施: 在施工總平面設(shè)計(jì)中人流和貨流的安全通道的規(guī)劃,倉庫、物料、機(jī)具的布置都要符合消防和安全衛(wèi)生規(guī)定,并落實(shí)消防和衛(wèi)生急救設(shè)施。 (2)、施工機(jī)械安 全: 按操作規(guī)程使用,加強(qiáng)對機(jī)械設(shè)備的管理,做到常檢、常修、常保養(yǎng),保持良好的工作狀態(tài)。 ( 3)、防臺風(fēng)、防雨、防雷措施:防雷接地可與工程的避雷預(yù)埋件臨時(shí)焊接連通,接地電阻達(dá)到規(guī)定要求,每月檢測一次,發(fā)現(xiàn)問題及時(shí)改正。設(shè)專人掌握氣象信息,及時(shí)作出臺風(fēng),大雨預(yù)報(bào),采取相應(yīng)技術(shù)措施,防止發(fā)生事故。禁止在臺風(fēng)、暴雨等惡劣的氣候條件下施 工。 (4)、及時(shí)進(jìn)行技術(shù)交底工作,并在施工過程中督促檢查。 (5)、進(jìn)行定期和不定期的安全檢查,及時(shí)發(fā)現(xiàn)和解決不安全的事故隱患,杜絕違章作業(yè)和違章指揮現(xiàn)象。 (6)、從事電工、起 重作業(yè)、各種機(jī)械的操作及機(jī)動車輛的駕駛?cè)藛T,必須持證上崗。 (7)、劃分安全區(qū)域,充分和正確使用安全標(biāo)志,布置適當(dāng)?shù)陌踩珮?biāo)語。 A、現(xiàn)場人員堅(jiān)持使用“三寶”。進(jìn)入現(xiàn)場人員必須戴安全帽,穿膠底鞋,不得穿硬底鞋、高跟鞋拖鞋或赤腳,高空作業(yè)必須系安全帶。 B、夜間施工:夜間操作要有足夠的照明設(shè)備,直接用于操作的照明燈采用 36V 低壓防爆工作燈。 安全用電技術(shù)措施 ( 1) 接地與接零 A、在施工現(xiàn)場專用的中性點(diǎn)直接接地的低壓電力線路中,必須采用 TNS 接零保護(hù)系統(tǒng)(即三相五線制)。 B、保護(hù)零線應(yīng)由工作接地線 或配電室的零線或第一級漏電保護(hù)器電源側(cè)地零線引出; C、保護(hù)零線應(yīng)與工作零線分開單獨(dú)敷設(shè),不作它用,保護(hù)零作PF 必須采用綠、黃雙色線; D、保護(hù)零線必須在配電室(或總配電箱)配電線路中間和末端至少三處作重復(fù)接地,重復(fù)接地線應(yīng)與保護(hù)零線相連接; E、保護(hù)零線的截面應(yīng)不小于工作零線的截面,同時(shí)必須滿意機(jī)械強(qiáng)度的要求,其中:架空敷設(shè)間距大于 12m 時(shí),采用絕緣銅線截面不小于 10mm2,采用絕緣鋁線截面不小于 16mm2,與電氣設(shè)備相連接的保護(hù)零線為截面不小于 的絕緣多股銅線; F、電氣設(shè)備的正常情況下不帶電的 金屬外殼、框架、部件、管道、軌道、金屬操作臺以及靠近帶電部分的金屬圍欄、金屬門等均應(yīng)作保護(hù)接零; G、供電電力變壓器中性點(diǎn)的直接工作接地電阻值應(yīng)小于 4 歐姆,保護(hù)零線重復(fù)接地電阻值應(yīng)小于 10 歐姆。不得一部分設(shè)備作保護(hù)接零,另一部分作保護(hù)接地。 ( 2)配置漏電保護(hù)器 A、施工現(xiàn)場的配電箱(配電室)和開關(guān)箱至少配置兩級漏電保護(hù)器; B、漏電保護(hù)器應(yīng)選用電流動作型,一般場合漏電保護(hù)器的額定漏電動作電流應(yīng)不大于 30mA,額定漏電動作時(shí)間應(yīng)不大于 ;潮濕和有腐蝕介質(zhì)場所的漏電保護(hù)器,其額定漏電動作電流不大于15mA,其額定漏電動作時(shí)間應(yīng)不大于 ;定額漏電動作電流和額定漏電動作時(shí)間乘積的極限值為(不大于) ; C、開關(guān)箱內(nèi)漏電保護(hù)器的選用應(yīng)與動力設(shè)備的容量大小、相數(shù)等實(shí)際情況相適應(yīng)、配配合,如三相電動機(jī)則應(yīng)選用參數(shù)匹配的三相三線的漏電保護(hù)器;照明用電必須與動力用電分開,照明應(yīng)選用單相二線的漏電保護(hù)器。 D、開關(guān)箱按三級設(shè)置,即總配電→分配電箱→開關(guān)箱,開關(guān)箱距離機(jī)具不能超過三米,開
點(diǎn)擊復(fù)制文檔內(nèi)容
試題試卷相關(guān)推薦
文庫吧 www.dybbs8.com
備案圖鄂ICP備17016276號-1