約為多少cm?已知:砂粒球度系數(shù)f=;砂層孔隙率m0=;砂層總厚度=70cm;水溫按15℃計。21. 根據(jù)19題所選砂濾料作反沖洗實驗。設(shè)反沖洗強度q=15L/(m2 s),且濾層全部膨脹起來,求濾層總膨脹度約為多少?(濾料粒徑按當量粒徑計)。已知:濾料密度=;水的密度=1g/cm3;濾層膨脹前孔隙率m0=;水溫按15℃計。22. 若濾池用砂作濾料,其孔隙率m0=,膨脹濾e=50%,當量直徑=,冬季沖洗水平均溫度為8℃,夏季水溫平均為26℃,試估算冬、夏季的沖洗強度,它們相差多少?23. 如果濾池沖洗強度為10L/(m2s),為了提高濾速,采用當量直徑為原粒徑一倍的濾料,問沖洗強度應(yīng)為多少才能達到同樣的膨脹率?24. 如果過濾速度為10m/h,過濾周期為24h,初步估算1m2濾池在過濾周期內(nèi)扣去沖洗水,凈生產(chǎn)多少水量,又砂層里截留了多少你(重量)?(停止過濾至沖洗完畢約需10-20分鐘,沖洗消耗清水約占濾池生產(chǎn)水量的1~3%)。(差一個進水濁度?)25. 簡述虹吸濾池的工作原理。虹吸濾池分格數(shù)如何確定?虹吸濾池與普通快濾池相比有哪些主要優(yōu)缺點?26. 設(shè)計和建造移動罩濾池,必須注意哪些關(guān)鍵問題?27. V型濾池的主要特點是什么?28. (長)4m(寬)。濾層厚70cm。沖洗強度q=14L/(),濾層膨脹度e=40%。采用3條排水槽,槽長4m。求:(1)標準排水槽斷面尺寸;(2)排水槽頂距砂面高度;(3)校核排水槽在水平面上總面積是否符合設(shè)計要求。29. 濾池平面尺寸、沖洗強度及砂濾層厚度同上題,并已知:沖洗時間6min;;大阻力配水系統(tǒng)開孔比a=%;;;。求:(1)沖洗水箱容積;(2)沖洗水箱底至濾池排水沖洗槽高度。30. 設(shè)計題:設(shè)計日處理廢水量為2500m3的雙層濾料濾池。需考慮5%的水廠自用水量(包括反沖洗用水),設(shè)計流速5m/h,沖洗強度13~16 L/(s m2),沖洗時間6min。要求設(shè)計計算出濾池面積及尺寸、濾池總高和反沖洗水頭損失等。31. A dualmedium filter bed posed of sand and anthracite is to be used for the filtration of settled secondary effluent. If the effective size of the sand in the dualmedium filter is to be , determine the effective size of the anthracite to avoid significant intermixing.32. 理想的濾池應(yīng)是怎樣的?第六章 消 毒1. 簡述水中加氯消毒的原理。2. 水處理中的消毒和微生物學(xué)中的滅菌有何區(qū)別?3. 為什么在水消毒中廣泛采用氯作為消毒劑?近年來發(fā)現(xiàn)了什么問題?4. 目前的消毒方法主要有哪幾種?簡要評述各種消毒方法的優(yōu)缺點。5. 消毒劑投加點如何選???應(yīng)考慮哪些因素?6. 什么叫自由性氯?什么叫化合性氯?兩者消毒效果有何區(qū)別?簡述兩者的消毒原理。7. 水的pH值對氯消毒作用有何影響?為什么?8. 什么叫折點加氯?出現(xiàn)折點的原因是什么?折點加氯有何利弊?9. 什么叫余氯?余氯的作用是什么?10. 簡述ClO2消毒原理和主要特點。11. 你認為在什么情況下需要聯(lián)合使用臭氧和氯來消毒。12. 已知:水廠凈產(chǎn)水量Q=6000m3/d=250m3/h。采用游離氯消毒,液氯加在水廠第二級泵站吸水管上,其壓水管直徑d=300mm,長度l=1200m。然后水經(jīng)高位水池進入城市管網(wǎng)。高位水池最高水位的容積W1=500m3,最低水位的容積W2=100m3。生活飲用水衛(wèi)生規(guī)范中規(guī)定采用氯消毒時,游離氯與水的接觸時間應(yīng)該大于30min。求:該系統(tǒng)氯消毒的接觸時間是否滿足要求。13. The following data were obtained for a percent inaction for a given bacterial strain at 10 ℃.Using these data develop a general relationship that can be used to model the observed data. Using the relationship developed, determine the chlorine dose required to achieve a percent inactivation in 60 min.Combined chlorine residual, mg/LContact time ,min22403924475286187128991014. 某原水20℃時的需氯量試驗結(jié)果如下:加氯量,mg/L余氯量,mg/L,接觸15min(1)繪制需氯量曲線;(2)指出達到折點時的加氯量;(3)。15. The chlorine residuals measured when various dosages of chlorine were added to a wastewater are given below. Determine(a) the breakpoint dosage and(b) the design dosage to obtain a residual of Dosage, mg/LResidual, mg/L016. 計算(1)折點氯化時氯對氨氮的化學(xué)計量比;(2)在折點氧化1mg/L的氨氮所需要的堿量。17. Design a chlorine contact basin for an average flow of 4000 m3/d. The estimated peaking factor is . The detention time at peak flow is to be 90min. A minimum of two parallel channels must be used for redundancy requirements. The dimensions of the chlorine contact basin should be such as to achieve a dispersion number of about at peak flow. Also check the dispersion number at average flow. What will happen if the low flow drops to 33 percent of the average flow in the early morning hours? Based on the resulting calculations, will solids deposition occur, requiring periodic scouring or cleaning of the chlorine contact basin? 第七章 膜技術(shù)1. 電滲析膜與離子交換樹脂在離子交換過程中的作用有何異同?2. 什么是電滲析的極化現(xiàn)象?它對電滲析器的正常運行有何影響?如何防止?3. 電滲析膜有幾種?良好的電滲析膜應(yīng)具備哪些條件?4. 利用電滲析法處理工業(yè)廢水有何特點?5. 電滲析器的電流效率與電能效率有何區(qū)別?6. 試畫出六級三段電滲析組裝示意圖。7. 反滲透與超濾在原理、設(shè)備構(gòu)造、運行上有何區(qū)別?有何聯(lián)系?8. 反滲透法除鹽與其它除鹽方法相比有何特點?9. 何謂滲透與反滲透?何謂滲透壓與反滲透壓?10. 試闡明超濾濃差極化過程中,膜面濃度Cm與壓力差ΔP之間的關(guān)系。11. 下表中列出電滲析器的運行資料,求該電滲析的電流效率。(膜的對數(shù)n=50,級(段)數(shù)=1)流量(m3/h)電流(A)電壓(V)離子濃度(mg/L)SO42HCO3Cl原水除鹽水原水除鹽水原水除鹽水51425026296126762