【文章內(nèi)容簡介】
of the power plant is not allowed. In addition, the measures against rain, snow, wind, sand, dust and static should be available. 3. Quoted standards序號(hào)SN標(biāo)準(zhǔn)代號(hào)Standard code標(biāo)準(zhǔn)名稱Standard name備 注RMKS1GB/428593《繼電保護(hù)和安全自動(dòng)裝置通用技術(shù)條件》General Technical Specifications for Relay Protection and Safety Automatic Device2GB/T1514594《 微機(jī)線路保護(hù)裝置通用技術(shù)條件》General Technical Specifications for Microprocessor Based Transmission Line Protector3GB/T1453793《量度繼電器和保護(hù)裝置的沖擊和碰撞試驗(yàn)》Impact and Crash Test of Measuring Relay and Protector4GB616285《靜態(tài)繼電器和保護(hù)裝置電器干擾試驗(yàn)》Electric Interference Test of Static Relay and Protector5GB5005992《3516kV變電所設(shè)計(jì)規(guī)程》Design Code for 3516kV Substation6GB7261《繼電器及繼電保護(hù)裝置基本實(shí)驗(yàn)方法》Basic Testing Method for Relay and Relay Protector7GB/T137291992《遠(yuǎn)動(dòng)終端通用技術(shù)條件》General Specifications for Remote Terminal Unit8GB5017192《電氣裝置安裝工程盤、柜及二次回路接線施工及驗(yàn)收規(guī)范》Code for Construction and Acceptance of Workbench, Cabinet and Secondary Circuit Wiring for Electrical Installation9DL47892《靜態(tài)繼電保護(hù)及安全自動(dòng)裝置通用技術(shù)條件》General Technical Specifications for Static Relay Protection and Safety Automatic Device10DL50021991《地區(qū)電網(wǎng)調(diào)度自動(dòng)化設(shè)計(jì)技術(shù)規(guī)程》Technical Code for Regional Power Grid Dispatching Automation Design11DL/5161993《電網(wǎng)調(diào)度自動(dòng)化系統(tǒng)運(yùn)行管理規(guī)程》Management Code for Power Grid Dispatching Automatic System Operation12DL/T6301997《交流采樣遠(yuǎn)動(dòng)終端通用技術(shù)條件》General Technical Specifications for AC Sampling Remote Terminal Unit13SDJ987《電測(cè)量儀表裝置設(shè)計(jì)技術(shù)規(guī)程》Technical Code for Design of Electric Measuring Instrument Device14SDJ79《變電所設(shè)計(jì)技術(shù)規(guī)程》Technical Code for Substation Design15GB7450《電子設(shè)備雷擊導(dǎo)則》Guidelines for Electronic Equipment against Thunder Strike16GB7260《不間斷電源設(shè)備》Uninterruptible Power Supply System17GB288998《計(jì)算機(jī)場(chǎng)地技術(shù)要求》Technical Requirements for Compute Field18GB/T137301992《地區(qū)電網(wǎng)數(shù)據(jù)采集與監(jiān)控系統(tǒng)通用技術(shù)條件》General Technical Specifications for Date Collection and Monitoring System of Regional Power Grids19DL516/1993《電網(wǎng)調(diào)度化系統(tǒng)運(yùn)行管理規(guī)程》Management Code for Power Grid Dispatching Automatic System Operation20JB33361983《電站設(shè)備自動(dòng)化裝置通用技術(shù)條件》General Technical Specifications for Power Station Automatic Device21JB57771991《面板、架和框的基本尺寸系列》Series of Basic Dimensions of Panels, Racks and Enclosures22GB1192089《電力系統(tǒng)二次電路用控制及繼電保護(hù)屏(柜、臺(tái))通用技術(shù)條件》General Technical Specifications for Control and Relay Protection Screen (Cabinet and Counter) for Power System Secondary Circuit23DL/T5271993《靜態(tài)繼電保護(hù)裝置逆變電源技術(shù)條件》Technical Specifications for Static Relay Protector Inverter Power Supply24DL/T47895《靜態(tài)繼電保護(hù)及安全自動(dòng)裝置通用技術(shù)條件》General Technical Specifications for Static Relay Protection and Safety Automatic Device25DL/T6341997《問答式傳送規(guī)約》Polling Transmission Protocol 26DL487《絕緣耐壓行業(yè)標(biāo)準(zhǔn)》Industry Standard for Voltage Resistance of Insulation27DL/T5871996《微機(jī)繼電器保護(hù)裝置運(yùn)行管理規(guī)程》Code for Operating Management of Microprocessorbased Relay Protector28《快速瞬變干擾試驗(yàn)》Fast Transient Interference Test29GB5017192《電器安裝工作盤,柜及二次回路接線施工及驗(yàn)收規(guī)范》Code for Construction and Acceptance of Workbench, Cabinet and Secondary Circuit Wiring for Electrical Installation 30SD27688《靜態(tài)比率差動(dòng)保護(hù)裝置技術(shù)條件》Technical Specifications of Static Percentage Differential Protector31IEC255211《振動(dòng)試驗(yàn)》Vibration Test32IEC255212《沖擊碰撞》Impact amp。 Collision33IEC2555《絕緣電壓,沖擊耐壓測(cè)試》Insulation Voltage, Impact Withstand Voltage Test34IEC2556《高頻干擾電壓測(cè)試》Highfrequency Interference Voltage Test35IEC529《防護(hù)等級(jí)》Protection Level36Q/KDL《變電站綜合自動(dòng)化系統(tǒng)》Integrated Automatic System for Substations企業(yè)標(biāo)準(zhǔn)Company standard4. Technical conditions建設(shè)標(biāo)準(zhǔn):Construction standards: 系統(tǒng)采用計(jì)算機(jī)監(jiān)控方式。按有人值守電廠進(jìn)行設(shè)計(jì),考慮四遙功能和遠(yuǎn)方管理,發(fā)電機(jī)單元集中組屏布置安裝方式,而其它6kV線路、6kV PT 、6kV母聯(lián)、6kV饋線(廠用變壓器、PT、母聯(lián)、)保護(hù)裝置均就地安裝于高壓開關(guān)柜上。各保護(hù)單元相互獨(dú)立,不互為影響。并能獨(dú)立完成其保護(hù)功能,通過通訊接口向后臺(tái)監(jiān)控系統(tǒng)傳送保護(hù)信息。低壓快切安裝在低壓柜內(nèi)。The system adopts puter monitoring mode and is designed in the mode of having personnel on watch for the plant。 4remote control function and remote management are considered。 the generator units adopt the centralized deployment installation mode while other 6kV line, 6kV PT, 6kV busbar, 6kV feed line (station transformer, PT and busbar) protective devices all are installed on the highvoltage switchgear. All protection units are mutually independent and not affect each other and can acplish their own protection function independently and send protection information to the back office monitoring system via the munication interface. The lowvoltage fast transfer device is installed in the lowvoltage switchgear.控制方式:Control mode: 各保護(hù)單元均能手動(dòng)操作開關(guān),裝置內(nèi)具有完善的防跳回路(也可解除),具備自檢功能及PT在線監(jiān)測(cè)工能。All protection units can operate the switch manually。 the inside of the device is inbuilt with perfect antitripping circuit (may be released) and has the selfcheck function and PT online monitoring function.性能概述:Performance summary: Normal Working Conditions電壓:176~260V DC power supplyVoltage: 176~260V Ambient temperature工作:0℃~40℃Working temperature: 0℃~40℃ 貯運(yùn):25℃~70℃,在極限值下不施加激勵(lì)量,裝置不出現(xiàn)不可逆變化,溫度恢復(fù)后,裝置應(yīng)能正常工作。Storage amp。 transportation temperature: 25℃~70℃. In limit value, without excitation vector applied, the device will not have irreversible change. After the temperature restores, the device should be able to work normally. 環(huán)境濕度:45%~75%,最濕月的月平均最大相對(duì)濕度為90%,同時(shí)該月的月平均最低溫度為25℃且表面無凝露。 Ambient humidity: 45%~75%, the monthly average max. RH of the wettest month is 90%。 the monthly average lowest temperature of that month is 25℃and no condensation occurs on the surface.:86kPa~106kPa Atmospheric pressure: 86kPa~106kPa Ambient environment裝置的使用地點(diǎn)應(yīng)無爆炸危險(xiǎn)、無腐蝕性氣體及導(dǎo)電塵埃、無嚴(yán)重霉菌、無劇烈振動(dòng)源,不允許有超過發(fā)電廠變電站范圍內(nèi)可能遇到的電磁場(chǎng)存在。有防御雨、雪、風(fēng)、沙、塵埃及防靜電措施。Ambient environment: The working place of the device should be free of explosion danger, without corrosive gas and conductive dust, severe mildew and violent vibration source。 the electromagnetic field that exceeds the scope of the transformer