【正文】
ration room of refrigeration system is set up in the basement. The cooling tower is fixed up on the roof of the fourth floor. The supermarkets and the lobby of the hotal are the main room in the first floor. The meeting rooms, offices and the hotal are on the second, third and fourth floors. The content of the heating, ventilation and airconditioning system design include: central airconditioning system(include the selection of the cooling and heating source), cooling water of airconditioning system, prevent and get rid of the smoke in the basement and ventilation system. The plet air system is adopted mainly in the rooms, whose height is more higher and the space is more spacious. And PAU and FCU system is adopted in the other rooms. At last, the measurements of weaken sound, prevent equipment from vibration and insulation are adopted to the equipment of the airconditioning system and pipeline.Keyword: prehensive building。當(dāng)領(lǐng)室有一定的發(fā)熱量時,通過空調(diào)房間隔墻、樓板、內(nèi)窗、內(nèi)門等內(nèi)維護結(jié)構(gòu)的溫差傳熱而產(chǎn)生的冷負(fù)荷,可視作穩(wěn)定傳熱,不隨時間而變化,可按下式計算:Qc(τ)=AiKi(+Δtα tR ) (32) 式中 Ki — 內(nèi)圍護結(jié)構(gòu)傳熱系數(shù),W/(m2?℃ ); Ai — 內(nèi)圍護結(jié)構(gòu)的面積,m2; — 夏季空調(diào)室外計算日平均溫度,℃;Δtα — 附加溫升,可按《暖通空調(diào)》表210查取。本設(shè)計中采用熒光燈,不同類型房間照明負(fù)荷計算時的系數(shù)表: 表32房間類型安裝方式n1n2空調(diào)運行時間照明負(fù)荷開燈時間開燈時數(shù)超市明裝14h35w/m28:0022:0014h大堂明裝24h30w/m216:0024:008h旅館入口明裝24h30w/m216:0024:008h衛(wèi)生間明裝24h18w/m216:0024:008h客房暗裝24h18w/m216:0024:008h走廊暗裝24h18w/m216:0024:008h辦公室暗裝24h20w/m216:0024:008h會議室暗裝24h20w/m216:0024:008h娛樂間暗裝24h23w/m216:0024:008h人體顯熱散熱形成的冷負(fù)荷Qc(τ) = qs n φ CLQ () 式中 Qc(τ) —人體顯熱散熱形成的冷負(fù)荷,W;qs — 不同室溫和勞動性質(zhì)成年男子顯熱散熱量,W,由《暖通空調(diào)》表213查得; n — 室內(nèi)全部人數(shù);φ — 群集系數(shù),由《暖通空調(diào)》表212查得;CLQ — 人體顯熱散熱冷負(fù)荷系數(shù),由《暖通空調(diào)》附錄223查得;人體潛熱散熱引起的冷負(fù)荷Qc = ql n φ () 式中 Qc—人體潛熱散熱形成的冷負(fù)荷,W;ql — 不同室溫和勞動性質(zhì)成年男子潛熱散熱量,W,由《暖通空調(diào)》表213查得;n,φ—同式()。因其各使用功能時間差異比較大,負(fù)荷分布不均勻等特點,決定采用了變水量系統(tǒng);因單式泵比較簡單且建筑只需一個系統(tǒng)分區(qū),所以采用了單式泵系統(tǒng);因兩管制方式簡單且初投資少,而且建筑地處北京,無內(nèi)區(qū),無需同時供冷和供熱且無特殊溫度要求,因而采用了兩管制系統(tǒng)。風(fēng)機盤管處理的風(fēng)量比其它方式大,不易選型。其焓濕圖如下:由圖可看出,根據(jù)室內(nèi)熱濕比線及室內(nèi)狀態(tài)點,查焓濕圖可得:i=48 KJ/Kg所以風(fēng)機盤管的風(fēng)量: = m3/s=199 m3/h (),所以M'==218 m3/h。新風(fēng)入口注意事項:(1)新風(fēng)進口位置:本系統(tǒng)采用獨立的新風(fēng)系統(tǒng),因此只須考慮風(fēng)機盤管機組配置合理;布置時應(yīng)盡量使排風(fēng)口與進風(fēng)口遠(yuǎn)離,進風(fēng)口應(yīng)盡量放在排風(fēng)口的上風(fēng)側(cè);為避免吸入室外地面灰塵,進風(fēng)口底部應(yīng)距地面不宜低于2m。查《05系列建筑標(biāo)準(zhǔn)設(shè)計圖集》選擇630250mm的方管,則實際流速為V=Q/3600F=查通風(fēng)管道比摩阻線算圖得 比摩阻 Rm=則Ⅰ段沿程阻力為 △Py= RmL==Ⅰ段局部阻力構(gòu)件有:散流器 ζ=1 調(diào)節(jié)閥ζ= 分流三通ζ=1 已知該段動壓v2ρ/2= 所以其局部阻力 △Pj=(1++1)v2ρ/2=管段12總阻力為: △P=△Py+△Pj=+=Ⅱ管段23風(fēng)量M=6650m3/h,根據(jù)公式: F斷面面積 m2 Q每小時的流量 m3/h V 流速 m/s所以F= m2。最大可能的減少風(fēng)量擾動對氣流產(chǎn)生的負(fù)面效應(yīng)。(9)防火閥的安裝位置必須與設(shè)計相符,氣流方向務(wù)必與閥體上標(biāo)志的箭頭相一致,嚴(yán)禁反向。2.冷凍水的水力計算(1)冷凍水量的計算公式: W=Q/Cρ(thtj) (61)式中: Q——風(fēng)機盤管負(fù)荷, kW; C——水的比熱, kJ/kg(2):根據(jù)各管段的冷負(fù)荷,計算各管段的流量,計算式如下: kg/h (63)式中: Q 管段的冷負(fù)荷, W; △t 供水回水的溫差, ℃本設(shè)計中由于設(shè)計工況與設(shè)備的標(biāo)準(zhǔn)工況較為接近,直接選用設(shè)備表中給出的冷凍水流量.(3):用假定流速法確定管段管徑。其中同程系統(tǒng)的特點在于供回水的水流方向相同,經(jīng)過每一環(huán)路的管路長度相等,優(yōu)點在于水量分配和調(diào)節(jié)方便,易于實現(xiàn)水利平衡。(5)所有水平或垂直的風(fēng)管,必須設(shè)置必要的支、吊或托架,其構(gòu)造形式由安裝單位在保證牢固、可靠的原則下根據(jù)現(xiàn)場情況選定,詳見國標(biāo)T616。18與a2i2管路的不平衡為(404368)/404100%=%15%因此,兩并聯(lián)管路阻力基本平衡,無需利用閥門來調(diào)節(jié)。首先選定系統(tǒng)最不利環(huán)路作為計算的出發(fā)點(一般是某一空調(diào)系統(tǒng)中最長管路或者局部構(gòu)件最多的管路)。這里不再詳細(xì)闡述,具體計算請看新風(fēng)機組選擇計算。則新風(fēng)比m= M/M=3) 求出混風(fēng)狀態(tài)點由圖可知,新風(fēng)比m=根據(jù)室外狀態(tài)參數(shù),干球溫度=,%,焓iO= KJ/Kg,可以計算出混風(fēng)點的 焓值,結(jié)果為:i=(iOiR)+ iR=65KJ/Kg4)選擇空氣處理機組已知混合風(fēng)處理到的狀態(tài)點i= KJ/Kg t=,所以機組實際承擔(dān)的負(fù)荷為Q=ΡM(i i)=695KW,考慮到8%的漏風(fēng)系數(shù),所以M'==9221364 m3/h, Q'==750KW,根據(jù)Q' 和M',可選用特靈空氣處理機組一臺,其型號為LPCQ095,8排盤管, kW,送風(fēng)量100000m3/h同樣可以得出其他空調(diào)機組的選型,B區(qū)可選用一臺特靈的空氣處理機組,其型號為LPCQ020,8排盤管, kW,送風(fēng)量19000m3/h。 2) 客房、辦公室等小房間,人員集中程度大,各房間的負(fù)荷根據(jù)運行時間不一致,且各自有不同要求,且受到層高的限制,因而選用了風(fēng)機盤管加獨立新風(fēng)系統(tǒng)形式。系統(tǒng)簡單與蓄熱水池連接比較復(fù)雜開式管路系統(tǒng)與大氣相通與蓄熱水池連接比較簡單易腐蝕,輸送能耗大同程式供回水干管中的水流方向相同;經(jīng)過每一管路的長度相等水量分配,調(diào)度方便,便于水力平衡需設(shè)回程管,管道長度增加,初投資稍高異程式供回水干管中的水流方向相反;經(jīng)過每一管路的長度不相等不需設(shè)回程管,管道長度較短,管路簡單,初投資稍低水量分配,調(diào)度較難,水力平衡較麻煩兩管制供熱、供冷合用同一管路系統(tǒng)管路系統(tǒng)簡單,初投資省無法同時滿足供熱、供冷的要求三管制分別設(shè)置供冷、供熱管路與換熱器,但冷熱回水的管路共用能同時滿足供冷、供熱的要求,管路系統(tǒng)較四管制簡單有冷熱混合損失,投資高于兩管制,管路系統(tǒng)布置較簡單四管制供冷、供熱的供、回水管均分開設(shè)置,具有冷、熱兩套獨立的系統(tǒng)能靈活實現(xiàn)同時供冷或供熱,沒有冷、熱混合損失管路系統(tǒng)復(fù)雜,初投資高,占用建筑空間較多單式泵冷、熱源側(cè)與負(fù)荷側(cè)合用一組循環(huán)水泵系統(tǒng)簡單,初投資省不能調(diào)節(jié)水泵流量,難以節(jié)省輸送能耗,不能適應(yīng)供水分區(qū)壓降較懸殊的情況復(fù)式泵冷、熱源側(cè)與負(fù)荷側(cè)分別配備循環(huán)水泵可以實現(xiàn)水泵變流量,能節(jié)省輸送能耗,能適應(yīng)供水分區(qū)不同壓降,系統(tǒng)總壓力低。η——電動機效率,可由產(chǎn)品樣本查得,Y系列電動機效率可由表211查得。/ 會議室:30 m179。一層主要為超市和旅館大堂,二、三、四層主要是會議室,辦公室和旅館。48ˊ 東經(jīng)116176。南北區(qū)劃分的標(biāo)準(zhǔn)為:建筑地點在北緯27176。圍護結(jié)構(gòu)的附加耗熱量包括:朝向修正率:北、東北、西北朝向: 0;東、西朝向: -5%;東南、西南朝向: -10%;南向: -20%。(2).初投資和運行費用綜合起來較為經(jīng)濟;(3).盡量減少一個系統(tǒng)內(nèi)的各房間相互不利的影響;(4).盡量減少風(fēng)管長度和風(fēng)管重疊,便于施工、管理和測試。1)A區(qū)中,由于房間熱濕比線較小,若采用露點送風(fēng),會使得送風(fēng)溫差較大,所以需進行再熱。依照同樣的方法,其他房間的風(fēng)機盤管選型如下 表52房間編號房間冷負(fù)荷 Q'(KW)風(fēng)機盤管型號名義風(fēng)量(m3/h)名義制冷量(KW)臺數(shù)101HFCF08211002注:風(fēng)機盤管機組的選擇都選用了中速制冷量、中速風(fēng)速,高靜壓型,且是冷量優(yōu)先,風(fēng)量校核。查《05系列建筑標(biāo)準(zhǔn)設(shè)計圖集》選擇2000800mm的方管,則實際流速為V=Q/3600F=查通風(fēng)管道比摩阻線算圖得 比摩阻 Rm=則Ⅵ段沿程阻力為 △Py= RmL==Ⅵ段局部阻力構(gòu)件有:靜壓箱 ζ= 直角彎頭 ζ=已知該段動壓v2ρ/2= Pa 所以其局部阻力 △Pj=(+)v2ρ/2= Pa管段67總阻力為: △P=△Py+△Pj=+=Ⅶ管段78風(fēng)量M=69956m3/h,根據(jù)公式:F斷面面積 m2Q每小時的流量 m3/hV 流速 m/s所以F=。一般可將送風(fēng)口的額定流量加大一檔。集中的空調(diào)房對分散的空調(diào)用戶供應(yīng)冷熱量時,常以水作為傳遞冷熱量的介質(zhì),通過水泵和管道輸送出去,使用后的回水又經(jīng)過管道返回空調(diào)機組中。本設(shè)計中由于設(shè)計工況與設(shè)備的標(biāo)準(zhǔn)工況較為接近,直接選用設(shè)備表中給出的冷凍水流量.(2)管徑的計算 d=(W/3600πV)1/210179。/h V——計算流速, m/s 冷凍水管內(nèi)水流速推薦值 表 61管徑/mm1520253240506580閉式系統(tǒng)開式系統(tǒng)管徑/mm 100125150200250300350400閉式系統(tǒng)開式系統(tǒng)注:風(fēng)機盤管與新風(fēng)機組的進出管徑由生產(chǎn)廠家提供。 冷凍水系統(tǒng)的水力計算1.水系統(tǒng)的選擇根據(jù)回水方式的不同,空調(diào)水系統(tǒng)有重力式和壓力式兩種,本設(shè)計采用壓力式,為封閉式回水系統(tǒng)。使吊頂平面保持平整,盡量使吊頂面的凸凹遠(yuǎn)離送風(fēng)口。查《05系列建筑標(biāo)準(zhǔn)設(shè)計圖集》選擇1600*1600mm的方管,則實際流速為V=Q/3600F=查通風(fēng)管道比摩阻線算圖得 比摩阻 Rm=則Ⅷ段沿程阻力為 △Py= RmL==2PaⅧ段局部阻力構(gòu)件有:直角彎頭 ζ=已知該段動壓v2ρ/2= 78 Pa 所以其局部阻力 △Pj=管段89總阻力為: △P=△Py+△Pj=2+=Ⅸ管段910風(fēng)量M=105381m3/h,初選風(fēng)速12