【正文】
floors in the building, among them, four floors are on the ground, and one is underground. The generation room of refrigeration system is set up in the basement. The cooling tower is fixed up on the roof of the fourth floor. The supermarkets and the lobby of the hotal are the main room in the first floor. The meeting rooms, offices and the hotal are on the second, third and fourth floors. The content of the heating, ventilation and airconditioning system design include: central airconditioning system(include the selection of the cooling and heating source), cooling water of airconditioning system, prevent and get rid of the smoke in the basement and ventilation system. The plet air system is adopted mainly in the rooms, whose height is more higher and the space is more spacious. And PAU and FCU system is adopted in the other rooms. At last, the measurements of weaken sound, prevent equipment from vibration and insulation are adopted to the equipment of the airconditioning system and pipeline.Keyword: prehensive building。 cooling water system. 目 錄1 緒論 1 1 1 1 1 1 1 1 22 工程概況和原始資料 3 3 3 3 濕度 3 4 4 43 各空調(diào)房間負(fù)荷計(jì)算 5 5 5 5 5 6 設(shè)備散熱形成的冷負(fù)荷 6 7 8 9 9 9 22 224空調(diào)系統(tǒng)方案的確定 38 38 39 空調(diào)系統(tǒng)的劃分原則 39 方案比較 40. 系統(tǒng)選擇 41 42 新風(fēng)系統(tǒng) 425 空調(diào)設(shè)備選擇計(jì)算 44 44 44 46 47 48 48 50 新風(fēng)機(jī)組的選擇計(jì)算 50 50 51 51 51 52 53 54 55 56 56 57 74: 746空調(diào)水系統(tǒng)的設(shè)計(jì) 76 空調(diào)水系統(tǒng)的設(shè)計(jì)原則 76 76 冷凍水系統(tǒng)的水力計(jì)算 76 76 78 每層水環(huán)路水力計(jì)算 80 冷凝水系統(tǒng)的水力計(jì)算 947設(shè)備及材料的選擇 96 96 分水器和集水器的構(gòu)造和用途 96 分水器和集水器的尺寸 96 97 97 98 99 100 100 101 102 102 1028機(jī)房的設(shè)計(jì)與布置 1039 消聲、減振與保溫設(shè)計(jì) 104 104 10水泵及風(fēng)機(jī)等設(shè)備的減振 104 104 105 10510冷凍水管的保溫設(shè)計(jì) 106 106 保溫材料的選擇 106結(jié)論 108謝辭 109參 考 文 獻(xiàn) 111 2 工程概況和原始資料北京某綜合樓,高5 層,為現(xiàn)澆混凝土框架結(jié)構(gòu),耐火等級(jí)為一級(jí),㎡,地下一層,地上四層, m。 由《簡(jiǎn)明空調(diào)設(shè)計(jì)手冊(cè)》得西安地區(qū)的主要參數(shù)如下:地理位置: 中國(guó) 北京市 臺(tái)站位置: 北緯39176。28ˊ 海 拔: 氣象參數(shù)為:夏季:大氣壓: 室外計(jì)算干球溫度:℃ 室外計(jì)算濕球溫度:℃ 日平均干球溫度:℃ 夏季平均日較差:℃ 室外平均風(fēng)速::72%冬季:大氣壓: 采暖室外干球溫度:℃ 空調(diào)室外干球溫度:℃相對(duì)濕度:45% 室外平均風(fēng)速:、濕度夏季: 溫度(℃) 相對(duì)濕度(%) 氣流平均速度(m/s)超市 26 60 ≤大廳 27 60 ≤走廊 27 60 ≤儲(chǔ)藏室 27 60 ≤衛(wèi)生間 27 60 ≤ 客房 26 60 ≤辦公室 26 60 ≤會(huì)議室 26 60 ≤娛樂(lè)室 26 60 ≤冬季:溫度(℃) 相對(duì)濕度(%) 氣流平均速度(m/s)超市 18 40 ≤大廳 17 40 ≤走廊 18 40 ≤儲(chǔ)藏室 17 40 ≤衛(wèi)生間 17 40 ≤ 客房 20 40 ≤辦公室 17 40 ≤會(huì)議室 19 40 ≤娛樂(lè)室 17 40 ≤超市:18 m179。/ 儲(chǔ)藏室:17m179。/ 客房:30 m179。/ 會(huì)議室:30 m179。/根據(jù)《辦公建筑設(shè)計(jì)規(guī)范》對(duì)建筑物室內(nèi)允許噪聲作了規(guī)定:辦公室 ≤4050 dB(A) 客 房 ≤4050 dB(A)會(huì)議室 ≤3545 dB(A) 大廳、走廊≤45 dB(A) 外墻 250mm厚加氣混凝土砌塊框架,外帖50mm厚聚苯板,內(nèi)抹20mm厚白灰 傳熱系數(shù)K= w/ m2.℃內(nèi)墻 填充墻(002002) 傳熱系數(shù)K= w/ m2.℃ 玻璃幕墻 雙層中空玻璃內(nèi)帖保溫膜 傳熱系數(shù)K= w/ m2.℃外窗 雙層窗3mm厚普通玻璃,鋁合巹窗框 傳熱系數(shù)K= w / m2.℃外門 雙層玻璃門 傳熱系數(shù)K= w/ m2.℃屋面 技術(shù)措施屋面結(jié)構(gòu)002現(xiàn)澆023706 傳熱系數(shù)K= w/ m2.℃3 各空調(diào)房間負(fù)荷計(jì)算詳細(xì)計(jì)算方法、過(guò)程及計(jì)算依據(jù)如下:根據(jù)《暖通空調(diào)》,對(duì)下列各項(xiàng)得熱量進(jìn)行計(jì)算。當(dāng)領(lǐng)室有一定的發(fā)熱量時(shí),通過(guò)空調(diào)房間隔墻、樓板、內(nèi)窗、內(nèi)門等內(nèi)維護(hù)結(jié)構(gòu)的溫差傳熱而產(chǎn)生的冷負(fù)荷,可視作穩(wěn)定傳熱,不隨時(shí)間而變化,可按下式計(jì)算:Qc(τ)=AiKi(+Δtα tR ) (32) 式中 Ki — 內(nèi)圍護(hù)結(jié)構(gòu)傳熱系數(shù),W/(m2?℃ ); Ai — 內(nèi)圍護(hù)結(jié)構(gòu)的面積,m2; — 夏季空調(diào)室外計(jì)算日平均溫度,℃;Δtα — 附加溫升,可按《暖通空調(diào)》表210查取。 Qc(τ) = cw Kw Aw ( tc(τ) + td tR) (33) 式中 Qc(τ) — 外玻璃窗瞬變傳熱引起的冷負(fù)荷,W; Kw — 外玻璃窗傳熱系數(shù),W/(m2?℃ ),由《暖通空調(diào)》附錄27和附錄28查得; Aw — 窗口面積,m2; tc(τ) — 外玻璃窗的冷負(fù)荷溫度的逐時(shí)值,℃,由《暖通空調(diào)》附錄210查得;cw — 玻璃窗傳熱系數(shù)的修正值;由《暖通空調(diào)》附錄29查得; td — 地點(diǎn)修正值,由《暖通空調(diào)》附錄211查得; Q(τ)= Cα Aw Cs Ci Djmax CLQ (34)式中 Cα— 有效面積系數(shù),由《暖通空調(diào)》附錄215查得;Aw— 窗口面積,m2;Cs— 窗玻璃的遮陽(yáng)系數(shù),由《暖通空調(diào)》附錄213查得;Ci— 窗內(nèi)遮陽(yáng)設(shè)施的遮陽(yáng)系數(shù),由《暖通空調(diào)》附錄214查得;Djmax— 日射得熱因數(shù),由《暖通空調(diào)》附錄212查得;CLQ— 窗玻璃冷負(fù)荷系數(shù),無(wú)因次,由《暖通空調(diào)》附錄216至附錄219查得;注: CLQ值按南北區(qū)的劃分而不同。30ˊ以南的地區(qū)為南區(qū),以北的地區(qū)為北區(qū)。如果空調(diào)系統(tǒng)不連續(xù)運(yùn)行,則CLQ=: Qs ——設(shè)備和用具的實(shí)際顯熱散熱量,W。n3——同時(shí)使用系數(shù),定義為室內(nèi)電子設(shè)備同時(shí)使用的安裝功率與總功率之比,。η——電動(dòng)機(jī)效率,可由產(chǎn)品樣本查得,Y系列電動(dòng)機(jī)效率可由表211查得。其他符號(hào)同式()電子設(shè)備:計(jì)算公式同公式(),其中系數(shù)n2的值根據(jù)使用情況而定,—。本設(shè)計(jì)中采用熒光燈,不同類型房間照明負(fù)荷計(jì)算時(shí)的系數(shù)表: 表32房間類型安裝方式n1n2空調(diào)運(yùn)行時(shí)間照明負(fù)荷開燈時(shí)間開燈時(shí)數(shù)超市明裝14h35w/m28:0022:0014h大堂明裝24h30w/m216:0024:008h旅館入口明裝24h30w/m216:0024:008h衛(wèi)生間明裝24h18w/m216:0024:008h客房暗裝24h18w/m216:0024:008h走廊暗裝24h18w/m216:0024:008h辦公室暗裝24h20w/m216:0024:008h會(huì)議室暗裝24h20w/m216:0024:008h娛樂(lè)間暗裝24h23w/m216:0024:008h人體顯熱散熱形成的冷負(fù)荷Qc(τ) = qs n φ CLQ () 式中 Qc(τ) —人體顯熱散熱形成的冷負(fù)荷,W;qs — 不同室溫和勞動(dòng)性質(zhì)成年男子顯熱散熱量,W,由《暖通空調(diào)》表213查得; n — 室內(nèi)全部人數(shù);φ — 群集系數(shù),由《暖通空調(diào)》表212查得;CLQ — 人體顯熱散熱冷負(fù)荷系數(shù),由《暖通空調(diào)》附錄223查得;人體潛熱散熱引起的冷負(fù)荷Qc = ql n φ () 式中 Qc—人體潛熱散熱形成的冷負(fù)荷,W;ql — 不同室溫和勞動(dòng)性質(zhì)成年男子潛熱散熱量,W,由《暖通空調(diào)》表213查得;n,φ—同式()。敞開水表面散濕量可按下式計(jì)算MW = 103 ()式中 MW— 敞開水表面散濕量,㎏/s ; W — 單位水面蒸發(fā)量,kg/(m2 以旅館入口(101)為例,冷、濕負(fù)荷計(jì)算結(jié)果如下: 各層冷負(fù)荷計(jì)算過(guò)程與一層超市1相同,計(jì)算結(jié)果如下: 表35一層各房間逐時(shí)冷負(fù)荷匯總表 時(shí)間旅館入口超市1超市2大堂超市3儲(chǔ)藏室衛(wèi)生間1衛(wèi)生間210:002582 69883 125404 8999 101067 484 204518 845 11:002557