freepeople性欧美熟妇, 色戒完整版无删减158分钟hd, 无码精品国产vα在线观看DVD, 丰满少妇伦精品无码专区在线观看,艾栗栗与纹身男宾馆3p50分钟,国产AV片在线观看,黑人与美女高潮,18岁女RAPPERDISSSUBS,国产手机在机看影片

正文內(nèi)容

110kv變電站畢業(yè)設計-展示頁

2024-08-21 11:15本頁面
  

【正文】 ine the capacity and model of the substation transformer, and finally, according to the maximum continuous operating current a nd short circuit calculations, selection, highvoltage fuses, isolating switches, busbars, insulators and wall bushings, voltage transformers, current transformers, thus pleting the 110kv substation once part of the design. KEY WORDS: substation, transformer, system design, wiring 洛陽理工學院畢業(yè)設計(論文) III 目 錄 前 言 ....................................................................................................... 1 第 1 章 變電站的分析與設計 ............................................................... 2 變電站負荷情況及所址概況 ................................................... 2 變電站的負荷分析 ................................................................... 3 第二章 電氣主 接線設計 ........................................................................ 6 110kV 電氣主接線 .................................................................... 7 35kV 電氣主接線 ...................................................................... 7 10kV 電氣主接線 ..................................................................... 11 站用電接線 ...............................................................................12 第三章 負荷計算及變壓器選擇 ..........................................................14 負荷計算 ...................................................................................14 站用負荷計算 ...............................................................15 10kV 負荷計算 ..............................................................15 35kV 負荷計算 ..............................................................15 110kV 負荷計算 ............................................................15 主變臺數(shù)、容量和型式的確定 .............................................15 變電 所主變壓器臺數(shù)的確定 .......................................15 變電所主變壓器容量的確定 .......................................15 變電站主變壓器型式的選擇 .......................................16 站用變臺數(shù)、容量和型式的確定 .........................................17 站用變臺數(shù)的確定 .......................................................17 站用變?nèi)萘康拇_定 .......................................................17 站用變型式的選擇 .......................................................17 第四章 最大持續(xù)工作電流及短路計算 ..............................................19 各回路最大持續(xù)工作電流 .....................................................19 短路電流計算點的確定和短路電流計算結(jié)果 ....................19 第五章 主要電氣設備選擇 ...................................................................27 電氣設備的選擇原 則 .............................................................27 洛陽理工學院畢業(yè)設計(論文) IV 高壓斷路器的選擇 .................................................................28 隔離開關(guān)的選擇 .....................................................................29 各級電壓母線及開關(guān)柜的選擇 .............................................30 絕緣子和穿墻套管的選擇 .....................................................33 電流互感器的配置和選擇 .....................................................33 參數(shù)選擇 ........................................................................33 型式選擇 ........................................................................33 電壓互感器的配置和選擇 .....................................................35 參數(shù)選擇 .......................................................................35 型式選擇 .......................................................................35 準確度測量 ...................................................................36 各主要電氣設備選擇結(jié)果一覽表 .........................................36 第六章 變電站防雷保護 .......................................................................37 防雷保護基本要求 ................................................................37 雷電侵入波保護 ....................................................................38 謝 辭 ........................................................................................................41 參考文獻 ..................................................................................................42 附錄一:短路電流計算公式 ................................................................43 附錄二:電氣主接線圖 .........................................................................46 外文資料翻譯 .........................................................................................48 洛陽理工學院畢業(yè)設計(論文) 1 前 言 電力工業(yè)是國民經(jīng)濟的一項基礎(chǔ)工業(yè)和國民經(jīng)濟發(fā)展的先行工業(yè),它是一種將煤、石油、天然氣、水能、核能、風能等一次能源轉(zhuǎn)換成電能這個二次能源的工業(yè),它為國民經(jīng)濟的其他各部門快速、穩(wěn)定發(fā)展提供足夠的動力,其發(fā)展水平是反映國家經(jīng)濟發(fā)展水平的重要標志。本文首先根據(jù)所擬訂的系統(tǒng)與線路及所有負荷的參數(shù),分析負荷發(fā)展趨勢。洛陽理工學院畢業(yè)設計(論文) I 110kV 變電站一次系統(tǒng)設計 摘 要 隨著工業(yè)時代的發(fā)展,電能已經(jīng)成為人類發(fā)展的主要能源,科學合理的駕馭電能必須從電力工程的設計和方法上掌握其精髓,提高電力系統(tǒng)運行的可靠性和穩(wěn)定性。從而達到降低生產(chǎn)成本提供經(jīng)濟效益的目的。從負荷增長方面闡明了建站的必要性,然后通過對擬建變電站的概括以及出線方向來考慮,并通過對負荷資料的分析,安全,經(jīng)濟及可靠性方面考慮,確定了 110kV, 35kV, 10kV 以及站用電的主接線,然后又通過負荷計算及供電范圍確定 了主變壓器臺數(shù),容量及型號,同時也確定了站用變壓器的容量及型號,最后,根據(jù)最大持續(xù)工作電流及短路計算的計算結(jié)果,對高壓熔斷器,隔離開關(guān),母線,絕緣子和穿墻套管,電壓互感器,電流互感器進行了選型,從而完成了 110kV 變電站一次部分的設計。 由于電能在工業(yè)和國民經(jīng)濟中的重要性,電能的輸送和分配是電能應用于這些領(lǐng)域不可缺少的部分。發(fā)電廠或 者上級變電站經(jīng)過合理調(diào)整后輸送給下級負荷,是輸電能送的核心部分。 若變電站系統(tǒng)中某一環(huán)節(jié)發(fā)生故障,系統(tǒng)保護環(huán)節(jié)將動作。 變電站是聯(lián)系發(fā)電廠和用戶的中間環(huán)節(jié),起著變換和分配電能的作用。變電站是匯集電源、升降電 壓和分配電力場所,是聯(lián)系發(fā)電廠和用戶的中間環(huán)節(jié)。升壓變電站通常是發(fā)電廠升壓站部分,緊靠發(fā)電廠。 現(xiàn)在,隨著大電網(wǎng)系統(tǒng)的建設,輸電的電壓等級越來越高,這一方面使降低損耗的需要,另一方面也是工業(yè)生產(chǎn)等負荷發(fā)展的需要。 本次設計的變電站為 110kV 變電站,其下級負荷為 35kV 級鄉(xiāng)鎮(zhèn)企業(yè)、農(nóng)業(yè)和 10kV 級工業(yè)及其它負荷。它們對供電的要求不同。 洛陽理工學院畢業(yè)設計(論文) 2 第 一 章 變電站的分析與設計 按照先行的原則,依據(jù)遠期負荷發(fā)展,決定在本區(qū)興建 一 中型 110kv變電站,該變電所建成后,主要對本區(qū)用戶供電為主,尤其對本地區(qū)大用戶進行供電。同時和其他地區(qū)變電所聯(lián)成環(huán)網(wǎng),提高了供電的穩(wěn)定性和電能的質(zhì)量。變電站的站址選擇靠近公路,有良好的交通運輸條件,同時也為變電站職工的生活提供了方便。地耐力為 2/cmkg ,天然容重 r= 2 3/cmg ,內(nèi)擦角 ? = 023 ,土壤電阻率為 100 cm.? ,變電所保護地下水位低,水質(zhì)良好,無腐蝕性。 氣象條件:年最高氣溫+ 40℃,年最低氣溫- 20℃,年平均氣溫+ 15℃,最熱月平均最高氣溫+ 32℃,最大復水厚度 b= 10mm,最大風速 25 sm/ ,屬于我國第六標準氣象區(qū)。此外,這些電力負荷位于變電站的北部和南部,變電站設在污染源的下風口(冬季主導風 向為西北風),受到輕微污染,影響電力系統(tǒng)的運行性能。因此,若變電站選址不當,必將影響企業(yè)供電系統(tǒng)的主接線方式,電網(wǎng)的損失及投資的大小,還可能引起電力倒流,甚至產(chǎn)生更嚴重的后果。 35kV 近期 4 回。 變電站的負荷分析 根據(jù)負荷允許停電程度的不同,可以將負荷分為三個等級,即一級負荷、二級負荷、三級負荷。如果停電,一級負荷將造成人身傷亡或引起對周圍環(huán)境嚴重污染對工廠將造成經(jīng)濟上的巨大損失,如重要的大型的設備損壞,重要產(chǎn)品或用重要原料
點擊復制文檔內(nèi)容
公司管理相關(guān)推薦
文庫吧 www.dybbs8.com
備案圖鄂ICP備17016276號-1