【正文】
load. And mainly wire the parison of the scheme according to load nature, the capacity, platform are counted after defining the main wiring form and mainly bee. And hold up in the electric current according to the impedance calculated for parameters systematically, anding has chosen to the main electric equipment and wire and checkup. Nobody stood on dutily and protected disposing to fit the routine. According to giving the topography a geographical condition , have assigned to the distribution device . To standing electrician go on and defend thunder protects and set up by building pletely The keyword : 〔Transformer substation The design 〕目 錄第一章 緒論 ................................................................................................................................................................6第二章 電氣主接線設(shè)計(jì) ..........................................................................................................................................6第一節(jié) 對(duì)電氣主接線的基本要求 .....................................................................................................................6第二節(jié) 對(duì)電氣主接線方案的初步設(shè)計(jì) ...............................................................................................................7第三節(jié) 幾種方案的比較及最終接線 ...................................................................................................................8第三章 短路電流計(jì)算 ..............................................................................................................................................9第一節(jié) 畫等值電路圖 ...........................................................................................................................................9第二節(jié) 計(jì)算短路電流 .......................................................................................................................................10第三節(jié) 短路電流計(jì)算結(jié)果匯總 .........................................................................................................................14第四章 主要電氣設(shè)備的選擇 ................................................................................................................................14第一節(jié) 變壓器選擇 .............................................................................................................................................14第二節(jié) 母線選擇 ...............................................................................................................................................16第三節(jié) 高壓斷路器選擇 .....................................................................................................................................17第四節(jié) 隔離開關(guān)的選擇 .....................................................................................................................................18第五節(jié) 電壓互感器的選擇 .................................................................................................................................21第六節(jié) 主要設(shè)備參數(shù) .........................................................................................................................................27第七節(jié) 型六氟化硫斷路器 ...............................................................................................................29第八節(jié) VS1(ZN63)型戶內(nèi)高壓真空斷路器 .......................................................................................................31第五章 繼電保護(hù)整定及配置 ..............................................................................................................................34第一節(jié) 概述 .........................................................................................................................................................34第二節(jié) 保護(hù)配置 .................................................................................................................................................34第三節(jié) 主變保護(hù)的整定計(jì)算 ...........................................................................................................................35第六章 防雷保護(hù)設(shè)計(jì) ..........................................................................................................................................38電氣工程學(xué)院本科生畢業(yè)設(shè)計(jì)說明書 第一章 緒論電力工業(yè)在社會(huì)主義現(xiàn)代化建設(shè)中占有十分重要的地位,因?yàn)殡娔芘c其他能源比較具有顯著的優(yōu)越性,它可以方便地與其他能量相互轉(zhuǎn)換,可以經(jīng)濟(jì)的遠(yuǎn)距離輸送,并在使用時(shí)易于操作和控制,根據(jù)工農(nóng)業(yè)生產(chǎn)的需要,決定新建一座 110kV 降壓變電所,培養(yǎng)綜合運(yùn)用所學(xué)知識(shí)的能力,擴(kuò)大和深化所學(xué)的理論知識(shí)和基本技能,從而使理論與實(shí)踐相結(jié)合。設(shè)計(jì)變電站為降壓變電站,其電壓等級(jí)為 110kV,具有中型容量的規(guī)模的特點(diǎn), 在系統(tǒng)中將主要承擔(dān)負(fù)荷分配任務(wù),從而該站主接線設(shè)計(jì)務(wù)必著重考慮可靠性。從負(fù)荷特點(diǎn)及電壓等級(jí)可知,它具有 13 10kV 三級(jí)電壓。35kV 出線回路數(shù)為 6 回;10kV 出線回路數(shù)為 8 回。2) 應(yīng)具有一定的靈活性。4) 經(jīng)濟(jì)上應(yīng)合理。第二節(jié) 對(duì)電氣主接線方案的初步設(shè)計(jì)電氣主接線基本要求:可靠性、靈活性、經(jīng)濟(jì)性三項(xiàng)基本要求。35kV 側(cè)的主接線形式根據(jù)《電力工程設(shè)計(jì)手冊(cè)》:1)35kV~ 的配電裝置出線回路數(shù)在 4~8 回時(shí)采用單母線分段接線。故選用單母線分段接線與雙母線接線兩種方案進(jìn)行比較決定 。故選用單母線分段接線與單母線分段帶旁母接線兩種方案進(jìn)行比較決定。2. 斷路器或母線故障以及母線檢修時(shí),盡量減少停運(yùn)的回路數(shù)和停運(yùn)時(shí)間。三、靈活性的要求1.調(diào)度時(shí),可靈活的投入和切除變壓器和線路,調(diào)配電源和負(fù)荷。3.?dāng)U建時(shí),容易從初期接線過渡到最終接線。2. 主接線力求簡單,以節(jié)省一次設(shè)備。4. 能限制短路電流,以便選擇價(jià)廉的設(shè)備。缺點(diǎn):不夠靈活可靠。當(dāng)一段母線發(fā)生故障,分段斷路器自動(dòng)將故障段切除,保證正常段母線供電,供電可靠性高。35kV 方案一:為“單母線分段接線”優(yōu)點(diǎn):不間斷供電和不致使重要用戶停電。2.當(dāng)出線為雙回路時(shí),常使架空出線呈交叉跨越。方案二:為“雙母線接線” 優(yōu)點(diǎn):供電可靠性高,一般不對(duì)歪停電。10kV 方案一:為“單母線分段接線”優(yōu)缺點(diǎn):同上方案二:為“單母線分段帶旁母接線”優(yōu)點(diǎn):供電可靠性高。由于待建變電所屬地區(qū)變電所,負(fù)荷主要是地區(qū)性負(fù)荷,該變電站110kV、35kV、10kV 側(cè)均采用單母線分段接線。電力系統(tǒng)所有電源都在額定負(fù)荷下運(yùn)行,其中 50%負(fù)荷在高壓母線上,50%負(fù)荷接在系統(tǒng)側(cè),短路發(fā)生在短路電流最大的瞬間,不考慮短路點(diǎn)的電弧阻抗和變壓器的勵(lì)磁電流,輸電線路的電容略去不計(jì)。當(dāng) Xjs39。當(dāng) Xjs39。8%/177。(5) 同級(jí)電壓的降壓變壓器容量的級(jí)別不宜過多,應(yīng)系列化,標(biāo)準(zhǔn)化(6) 對(duì)于大城市市郊的一次變電站,在中低壓側(cè)已構(gòu)成環(huán)網(wǎng)的基礎(chǔ)上,變 電所以裝設(shè)兩臺(tái)變壓器為宜。3. 變壓器繞組數(shù)量的選擇根據(jù):在具有三種電壓的變電站中,如通過主變各側(cè)的功率均達(dá)到該主變 容量的 15%及以上,或低壓側(cè)雖無負(fù)荷,但在變電所內(nèi)需裝設(shè)無功功率補(bǔ)償 設(shè)備時(shí),主變宜采用三繞組變壓器。第三繞組用三角形連接。6. 當(dāng)聯(lián)絡(luò)變壓器為兩臺(tái)時(shí),考慮一臺(tái)突然切除后,另一臺(tái)短時(shí)承擔(dān)全部負(fù)荷,因此選擇每臺(tái)變壓器的容量為總?cè)萘康?50~75%,采用 50%時(shí),一臺(tái)變壓器突然切除,另一臺(tái)過載倍率為 2,允許運(yùn)行 分鐘,采用 75%時(shí),過載倍率為 ,允許運(yùn)行 2 小時(shí),應(yīng)保證上述時(shí)間內(nèi)電網(wǎng)調(diào)度能妥善的調(diào)整系統(tǒng)潮流,降低聯(lián)絡(luò)點(diǎn)的穿越功率。2)在需要變壓器并聯(lián)以相互備用的情況下,使用兩臺(tái)變壓器比較便利。,發(fā)電廠、變電站高、中壓電網(wǎng)的聯(lián)絡(luò)變壓器一