10kv變電站的電氣一次設(shè)計-展示頁

2024-12-18 02:52本頁面
  

【正文】 tion number and capacity. Secondly, the paper design of the power plant and distribution work, conducted a workshop and the workshop substation electrical distribution systems and plant design, in accordance with the economic current density method, select the appropriate wire and cable, through a reasonable set shortcircuit point, for correct shortcircuit current calculation, carried out a major electrical equipment selection and validation. . Key words: power system, load calculation, transformer , equipment selection 西南科技大學(xué)城市學(xué)院本科生畢業(yè)論文 III 目 錄 第 0 章、緒 論 ...............................................................................................................1 第 1 章、分析原始資料,確定電源的引入方式 ...........................................................3 ......................................................................................................3 ..........................................................................3 工廠負(fù)荷情況 ......................................................................................................3 供電電源 請況 ......................................................................................................4 ..............................................................................................................4 第 2 章、負(fù)荷計算及無功功率補償計算 .......................................................................5 用電設(shè)備負(fù)荷的計算 .........................................................................................5 負(fù)荷計算表 .........................................................................................................6 無功功率補償 ......................................................................................................7 第 3 章、變電站的位置與型式、合理 地布置好各設(shè)備的位置 .................10 . 主變壓器選擇 ..................................................................................................10 ........................................................................................10 第 4 章、變電站主變壓器的臺數(shù)、容量及類型的選擇 .............................................13 第 5 章、變電站主結(jié)線方案的設(shè)計 .............................................................................14 變電所主要結(jié)線方案的提出 ............................................................................14 變電所主要結(jié)線方案的選擇 ............................................................................14 第 6 章、短路電流的計算 .............................................................................................19 繪制計算電路圖 ...............................................................................................19 計算短路電流 ...................................................................................................19 第 7 章、變電 站一次設(shè)備的選擇 .................................................................................22 10KV 側(cè)一次設(shè)備的選擇校驗 .........................................................................22 380V 側(cè)一次設(shè)備的選擇校驗 ..........................................................................26 第 8 章、防雷接地 .........................................................................................................32 變電站的防雷設(shè)計 ............................................................................................32 接地保護系統(tǒng)設(shè)計 ...........................................................................................35 第 9 章、設(shè)備材料清單 ...........................................................................................38 結(jié) 論 ...............................................................................................................................40 西南科技大學(xué)城市學(xué)院本科生畢業(yè)論文 IV 致 謝 .............................................................................................................................41 主要參考文獻 .................................................................................................................42 西南科技大學(xué)城市學(xué)院本科生畢業(yè)論文 1 第 0 章 緒 論 電能是現(xiàn)代工業(yè)生產(chǎn) 的主要能源和核心動力。 西南科技大學(xué)城市學(xué)院本科生畢業(yè)論文 I 10KV 變電站的電氣一次設(shè)計 摘要 :本設(shè)計 設(shè)計了一個 電子 廠的供電系統(tǒng),在滿足工廠供電設(shè)計中安全、可靠、優(yōu)質(zhì)、經(jīng)濟的基本要求的前提下,本文首先根據(jù)全廠和車間的用電設(shè)備情況和生產(chǎn)工藝要求,進行了負(fù)荷計算,通過功率因數(shù)的計算,進行無功補償設(shè)計(包括無功補償容量計算和補償設(shè)備選擇、校驗),確定了 電子 廠的供電方案,通過技術(shù)經(jīng)濟比較,確定了供電系統(tǒng)的主接線形式,選擇了主變壓器的臺數(shù)和容量。其次,本文設(shè)計了廠區(qū)供電和配電網(wǎng)絡(luò),進行了車間變電所以及車間配電系統(tǒng)和車間電氣設(shè)計,按照經(jīng)濟電流密度法,選擇了合適的導(dǎo)線和電纜,通 過合理設(shè)置短路點,進行正確的短路電流計算,進行了主要電氣設(shè)備的選型和校驗。電能既易于由其它形式的能量轉(zhuǎn)換而來,又易于轉(zhuǎn)換為其它形式的能量以供應(yīng)用;電能的輸送的分配既簡單經(jīng)濟,又便于控制、調(diào)節(jié)和測量,有利于實現(xiàn)生產(chǎn)過程自動化。 在企業(yè)工廠里,電能雖然是工業(yè)生產(chǎn)的主要能源和動力,但是它在產(chǎn)品成本中所占的比重一般很小(除電化工業(yè)外)。從另一方面來說,如果工廠的電能供應(yīng)突然中斷,則對工業(yè)生產(chǎn)可能造成嚴(yán)重的后果。由于能源節(jié)約是工廠供電工作的一個重要方面,而能源節(jié)約對于國家經(jīng)濟建設(shè)具有十分重要的戰(zhàn)略意義,因此做好工廠供電工作,對于節(jié)約能源、支援國家經(jīng)濟建設(shè),也具有重大的作用。 ( 2) 可靠: 應(yīng)滿足電能用戶對供電可靠性的要求。 此外,在供電工作中,應(yīng)合理地處理局部和全局、當(dāng)前和長遠等關(guān)系,既要照顧局部的當(dāng)前的利益,又要有全局觀點,能顧全大局,適應(yīng)社會的發(fā)展。目前多以采用自動裝置,將計算機應(yīng)用到工廠配電控制系統(tǒng)中去 。 ( 2) 安全可靠、先進合理; 應(yīng)做到保障人身和設(shè)備的安全,供電可靠,電能質(zhì)量合格,技術(shù)先進和經(jīng)合理,采用效率高、能耗低和性能先進的電氣產(chǎn)品。 ( 4)全局出發(fā)、統(tǒng)籌兼顧。工廠供電設(shè)計是整個工廠設(shè)計中的重要組成部分。作為從事工廠供電工作的人員,有必要了解和掌握工廠供電設(shè)計的有關(guān)知識,以便適應(yīng)設(shè)計工作的需要。 工廠負(fù)荷情況 本廠的供電均為三級負(fù)荷,統(tǒng)計資料如表 11 所示: 表 11 負(fù)荷統(tǒng)計資料 序號 用電設(shè)備組 名稱 容量 Pe 需要系數(shù) Kd cosamp。 1 生產(chǎn)車間 1 200 2 生產(chǎn)車間 2 200 3 生產(chǎn)車間 3 200 西南科技大學(xué)城市學(xué)院本科生畢業(yè)論文 4 4 老化室 1 1200 5 老化室 2 1200 6 老化室 3 1200 7 工模室 60 8 研發(fā)室 60 9 倉庫 1 300 10 倉庫 2 300 11 辦公室 1 60 12 辦公室 2 60 13 辦公室 3 60 14 廠區(qū) 60 供電電源請況 按與供電局協(xié)議,公司可由附近一條 10kv 的公 用電源干線取得工作電源。該干線的導(dǎo)線牌號為 LGJ150,導(dǎo)線為等邊三角形排列,線距了 2m;干線首端距離本廠約 8km。此斷路器配備有定時限過電流保護和電流速斷保護,定時限電流保護整定的動作時間為 。 本廠地區(qū)最高溫度為 35 度,最熱月平均最高氣溫為 28 度。為 、 cosamp。 其中 tanamp。的正切值,則Q30=P30tanamp。=100KVA 計算電流 I30=S30/= 所以生產(chǎn)車間的總有功計算負(fù)荷為: P= 3P30= 150kw 總無功計算負(fù)荷為: Q=3Q30= (2) 老化室 1 、 老化室 2 、老化室 3 按需要系數(shù)法確定計算負(fù)荷 有功計算負(fù)荷 P30=kdPe 取 kd 為 、 tanamp。為 ,車間的用電總設(shè)備容量為 Pe=1200kw.則 P30=kdPe=1200*=360kw 無功計算負(fù)荷 Q30=P30tanamp。為車間功率因數(shù) cosamp。=360*= 視在計算負(fù)荷 S30=P30/cosamp。為 、 cosamp。 其中 tanamp。的正切值,則Q30=
點擊復(fù)制文檔內(nèi)容
研究報告相關(guān)推薦
文庫吧 www.dybbs8.com
備案圖鄂ICP備17016276號-1