【正文】
procedures and design principle, design process for substation the size and form, concrete analysis of concrete problems. This is the 60kv/10kv substation of a substation designThis design including the selection of conductors, the selection of main transformer, reactive power pensation capacitors, the main electrical wiring, shortcircuit calculation, all kinds of electrical equipment choice and verification, the planning and design of high voltage distribution device. In the design and selection of equipment are fully taken into account the reliability, flexibility and economy. In addition, a variety of circuit breaker, isolating switch, current transformer model should be selected with the high voltage distribution device arrangement linked to consider.This design is a written instructions and diagrams explain the relatively plete substation design.Keywords power system; electrical equipment,;transformer; Transformer substation目錄摘要.........................................................................................................................................IAbstract.................................................................................................................................II第1章 緒論 ..........1 課題背景 .1 合理設計變電站的意義 .1 變電站設計相關的原則和規(guī)范................................................................................2第2章10kv線路導線的選擇 ..4 .4第3章 選擇主變壓器的臺數(shù)、容量、型號.............................................................9 線路損耗的總功率...............................................................................................9 .......................................................................................9 ......................................................................................10 ....................................................................................................11第4章 補償電容器的選擇............................................................................................13 ...........................................................................................13 ......................................................................................13 ....................................................................13 ..................................................................................13 .............................................................................................................14第5章 電氣主接線方案設計.......................................................................................16 ......................................................................................16 .............................................................................................................17 第6章 短路電流的計算............................................................................................18 .........................................................................18 ...........................................................................................................18 ....................................................................................................18第7章 電氣設備的選擇................................................................................................20 .........................................................................................................20 ....................................................................................................23 .........................................................................................................24 ........................................................................................................27 ...............................................................................................28 ............................................................................................................28結論......................................................................................................................................33致謝......................................................................................................................................34 參考文獻.............................................................................................................................35 附錄A..................................................................................................................................36附錄B...................................................................................................................................37 千萬不要刪除行尾的分節(jié)符,此行不會被打印。另外,各種斷路器、隔離開關、電流互感器型號的選擇要與高壓配電裝置的布置聯(lián)系在一起考慮。本設計包括對導線的選擇,主變壓器的選擇,無功補償靜電電容器的選擇,電氣主接線的確定,短路計算,各種電氣設備的選擇與校驗,高壓配電裝置的規(guī)劃設計。由于變電所的設計內容多、范圍廣、邏輯性強,因此要求要有較高的專業(yè)水平,并熟悉各種設計規(guī)程和設計原理,設計過程中要針對變電所的規(guī)模和形式,具體問題具體分析。60kV變電站一次部分設計摘要隨著工業(yè)時代的不斷發(fā)展,人們對電力供應的要求越來越高,特別是供電的穩(wěn)固性、可靠性和持續(xù)性。然而電網(wǎng)的穩(wěn)固性、可靠性和持續(xù)性往往取決于變電站的設計和配置。本文是60kv/10kv降壓變電所的一次變電的設計方案。在設計和選擇設備中都充分考慮到了可靠性,靈活性和經(jīng)濟性。本設計是有文字說明和圖表解釋的比較完整的變電所的設計方案。在目錄上點右鍵“更新域”,然后“更新整個目錄”。我國是世界能源消費大國,煤炭消費總量居世界第一位,電力消費總量居世界第二位,但一次能源分布和生產(chǎn)力發(fā)展水平卻很不均衡。這種能源分布與消費的不平衡狀況,決定了能源資源必須在全國范圍內優(yōu)化配置,必須以大煤電基地、大水電基地為依托,實現(xiàn)煤電就地轉換和水電大規(guī)模開發(fā)。長期以來,我國電網(wǎng)發(fā)展嚴重滯后。建設堅強的國家電網(wǎng),必須堅持統(tǒng)一規(guī)劃。必須堅持實施集約化管理。必須大力推廣典型設計。 合理設計變電站的意義 隨著科學技術的發(fā)展,作為現(xiàn)代工業(yè)發(fā)展的基礎和先行官—電力工業(yè),也隨之有了很大的發(fā)展。由于大電網(wǎng)的出現(xiàn),世界各國電力工業(yè)發(fā)展和運行的經(jīng)驗說明:電力系統(tǒng)愈大,調度運行就愈能合理和優(yōu)化,經(jīng)濟效益就愈好,應變事故的能力就愈強。 60kV變電所是電力配送的重要環(huán)節(jié),也是電網(wǎng)建設的關鍵環(huán)節(jié)。隨著國民經(jīng)濟的發(fā)展,工農業(yè)生產(chǎn)的增長需要,迫切要求增長供電容量,擬新建66kV變電所。隨著變電所綜合自動化技術的發(fā)展與進步,變電站綜合自動化系統(tǒng)取代或更新傳統(tǒng)的變電所二次系統(tǒng),繼而實現(xiàn)“無人值班”變電所已成為電力系統(tǒng)新的發(fā)展方向和趨勢。 變電站設計相關的原則和規(guī)范 開展60kv及以下輸配電工程典型設計的原則是:安全可靠、自主創(chuàng)新、技術先進;標準統(tǒng)一、覆蓋面廣、提高效率;注重環(huán)保、節(jié)約資源、降低造價;努力做到統(tǒng)一性和可靠性、適應性、先進性、經(jīng)濟性和靈活性的協(xié)調統(tǒng)一。可靠性:各個模塊安全可靠,通過模塊拼接得到的技術方案安全可靠。先進性:推廣應用電網(wǎng)新技術,鼓勵設計創(chuàng)新;典型設計各項技術經(jīng)濟可比指標先進。靈活性:典型設計模塊劃分合理,接口靈活,組合方案多樣,增減方便,便于調整概算,方便使用。銅導線雖然導電性能好,機械強度高,在抗氧化、抗腐蝕能力。鋁導線雖具有很好的導電性,價格低廉,但由于機械強度較差,大約為銅的一半,此外鋁易氧化,抗腐蝕性差,因此也不宜采用。因此本變電所的架空線路采用鋼芯鋁絞線,符號:LGJ—**,其中**為導線的標稱截面(mm2)。. 選擇機械制造廠出線架空線型號已知線路長度為3km,雙回線路供電,雙回出線重要負荷率不超過60%,遠期最大負荷為3500kW,功率因數(shù),最大負荷利用小