【正文】
ion valve oil stops up seriously, carries on the clean using the absolute ethyl alcohol, again severely newly installs。 The cold side, consisting of the expansion valve and the cold coil, is generally placed into a furnace or some other air handler. The air handler blows air through ducts. The hot side known as the condensing unit, lives outside the building. The unit consists of a long, spiral coil shaped like a cylinder. Inside the coil is a fan, to blow air through the coil, along with a weatherresistant pressor and some control logic. This approach has evolved over the years because it is lowcost, and also because it normally results in reduced noise inside the house (at the expense of increased noise outside the house). Besides the fact that the hot and cold sides are split apart and the capacity is higher (making the coils and pressor larger), there is no difference between a splitsystem and a window air conditioner. In warehouses, businesses, malls, large department stores, etc., the condensing unit normally lives on the roof and can be quite massive. Alternatively, there may be many smaller units on the roof, each attached inside to a small air handler that cools a specific zone in the building. Let39。s say that you plan to use the air conditioner in the summer (four months a year) and it will be operating about six hours a day. Let39。s say that you have a choice between two 10,000BTU units. One has an EER of and consumes 1,200 watts, and the other has an EER of 10 and consumes 1,000 watts. Let39。re seeing! The Many Faces of Cool Air conditioners e in various sizes, cooling capacities and prices. One type that we see all the time is the window air conditioner. Window air conditioners are an easy and economical way to cool a small area. Most people who live in suburban areas usually have one of these in their backyard: If you live in an apartment plex, this is probably a familiar sight: Most businesses and office buildings have condensing units on their roofs, and as you fly into any airport you notice that warehouses and malls may have 10 or 20 condensing units hidden on their roofs: And then if you go around back at many hospitals, universities and office plexes, you find large cooling towers that are connected to the air conditioning system: Even though each of these machines has a pretty distinct look, they all work on the same principles. Let39。 英文 How Air Conditioners Work and energy conservation technology research Abstract: An air conditioner is basically a refrigerator without the insulated box. It uses the evaporation of a refrigerant, like Freon, to provide cooling. The mechanics of the Freon evaporation cycle are the same in a refrigerator as in an air conditioner. Keywords: water towers 、 weatherresistant、 pressor、 energy conservation When the temperature outside begins to climb, many people seek the cool fort of indoor air conditioning. Like water towers and power lines, air conditioners are one of those things that we see every day but seldom pay much attention to. Wouldn39。本系統(tǒng)占地面積小,整個系統(tǒng)運行無需看護、低噪聲、無異味;節(jié)能高、環(huán)保好;不產(chǎn)生有害物質,對環(huán)境沒有不良影響。 3)遠程控制:通過遠程通訊接口與計算機連接,實現(xiàn)遠程控制,運行狀態(tài)可視化。 4.系統(tǒng)特色 1)全閉 環(huán):將中央空調的主機、輔機、循環(huán)系統(tǒng)等作為整體構成節(jié)能控制系統(tǒng),尋求一種最佳的控制規(guī)律,使中央空調主機、冷媒流量系統(tǒng)都隨負荷 Q的變化而變化,旨在滿足空調區(qū)舒適性所需負荷 Q前提下,實現(xiàn)整個系統(tǒng)最大程度的節(jié)能。經(jīng)理論計算,與恒流量中央空調系統(tǒng)相比,全年平均節(jié)電率可達 20%30%。 4)多參量非線性控制:本系統(tǒng)為多參量、時變、非線性系統(tǒng),以計算 機為控制手段,設計一套具有自尋優(yōu)自適應的智能控制、功能完善的穩(wěn)定安全的控制系統(tǒng)。輔機節(jié)能不少于 40%。 2)輔機節(jié)能:各種泵類(冷凍泵、冷水泵、風機等)的運行節(jié)能。智能控制器依據(jù)所采集的實時數(shù)據(jù)及系統(tǒng)的歷史運行數(shù)據(jù),計算出主機冷凝器的最佳熱轉換溫度(拐點溫度)及冷卻水最佳出、入口溫度,并以此調節(jié)冷卻水泵和冷卻塔風機變頻器的輸出頻率,控制冷卻水泵和冷卻塔風機轉速,動態(tài)調節(jié)冷卻水的流量和冷卻塔風機的風量,使冷卻水的進、出口溫度逼近智能控制器給出的最優(yōu)值,從而保證中央空調主機隨時處于最佳轉換效率狀態(tài)下運行。冷卻水及冷卻塔風機系統(tǒng)采用最佳轉換效率控制。由于冷凍水系統(tǒng)采用了輸出能量的動態(tài)控制,實現(xiàn)空調主機冷媒流量跟隨末端負荷的需求供應,使空調系統(tǒng)在各種負荷情況下,都能既保證末端用戶的舒適性,又最大限度地節(jié)省了系統(tǒng)的能量消耗 。對冷凍水系統(tǒng)采用最佳輸出能量控制。動態(tài)負荷跟蹤節(jié)能控制系統(tǒng)原理圖見圖 1。 本研究課題將摒棄以往的控制方案,以模型辨識、隨動控制系統(tǒng)理論、智能控制系統(tǒng)理論為基礎,與中央空調主機制冷技術與冷媒循環(huán)系統(tǒng)控制相結合,以變頻技術為輔助手段,實現(xiàn)中央空調全系統(tǒng)的整體協(xié)調運行和綜合性能優(yōu)化。 3.動態(tài)負荷跟蹤的節(jié)能控制方案 傳統(tǒng)的中央空調系統(tǒng)的調節(jié)方案是:采用恒流量模式或冷源側恒流量但負荷側變流量模式,系統(tǒng)所需負荷是按最大負荷、最惡劣的氣象條件及最差的使用工作環(huán)境來設計, 而實際運行時 50%以上的時間,系統(tǒng)所需負荷都在 50%以下,存在有極大的能量浪費。 5)動態(tài)負荷跟蹤的節(jié)能控制系統(tǒng)以整個中央空調系統(tǒng)為一 體,根據(jù)空調區(qū)負荷不斷變化的狀況,通過改變主機及循環(huán)系統(tǒng)內各參數(shù)運行變化情況,同步跟蹤負荷的變化,以實現(xiàn)在滿足負荷需求的前提下及時定量供給冷量,即做到 ―按需供應 ‖,基本達到 ―不滯后、不多給、不少給 ‖的目的。目前一般都采用降低室內溫度標準、提高冷水初溫等措施實現(xiàn)制冷主機的節(jié)能。這種方法簡便實用,節(jié)電效果明顯,但水泵、風機等產(chǎn)品屬系統(tǒng)輔機部分,占整個系統(tǒng)能耗約為 40%,所以挖掘空間有限。 4)中央空調系統(tǒng)中單個耗能設備節(jié)能改造。相對于空氣和土壤而言,水是最為理想的空調用冷熱源,水源熱泵也因此具有環(huán)保、高效、節(jié)能等眾多優(yōu)點,但我國水源熱泵技術研究還不是很成熟,與一些發(fā)達國家相比還存在一定的差距。這種方法本身并不節(jié)能省電,而是優(yōu)化了電網(wǎng)供電,對已經(jīng)實行分時電價的地區(qū),起到 省錢不節(jié)能 的作用,具地區(qū)性推廣意義。 2)蓄能空調。但是新風量的最小供應一方面國家已有標準,另外新風量不足將影響空氣質量,危及人體健康。 2.空調節(jié)能系統(tǒng)的研究概況 1)通過負荷控制 ,達到節(jié)能目的。從空調的壓焓圖來看,只有運行在在最佳的工況和條件,才 能發(fā)揮空調的最大制冷量,達到空調節(jié)能的目的。依靠技術創(chuàng)新、體制創(chuàng)新,節(jié)能降耗,提高能源利用效率,保證在 能源消耗最少,環(huán)境污染最小的基礎上,實現(xiàn) 節(jié)能優(yōu)先,結構多元,環(huán)境友好 的能源發(fā)展戰(zhàn)略。因此,節(jié)能尤其是節(jié)電,不僅具有重大的社會意義而且具有迫切的現(xiàn)實意義。這給中央空調的節(jié)能控制帶來了嚴峻的課題,也給廣大的節(jié)能控制領域的工作者帶來了極大的施展才華的空間。一般,冷負荷在 5~ 60%范圍內波動,大多數(shù)建筑物每年至少 70%是處于這種情況。中央空調的設計容量是按最大負荷計算的,而大部份建筑物一年中只有幾十天時間中央空調處于最大負荷狀態(tài)。 近年來,我國大部分地區(qū),尤其是東南沿海地區(qū)夏季空調能耗正在急劇上升,空調用電激增的趨勢已引起電網(wǎng)供電緊張。中央空調控制也就是把管路、管件、閥體或閥門集中設定控制流體提供冷氣。變水量系統(tǒng)對水泵系統(tǒng)的節(jié)能效率依水泵的控制方式和 VWV使用比例而異,一般 VWV的控制方式有無段變速 (SP)與雙向閥控制方式。這兩種方式透過風量的調整來減少送風機的耗電量,同時也可增加熱源機器的運轉效率而節(jié)約熱源耗電,因此可在送風及熱源兩方 面同時獲得節(jié)能效果。 AHUVAV系統(tǒng)是在全風管系統(tǒng)中將送風溫度固定,而以調節(jié)送風機送風量的方式來應付室內空調負荷的變動。變風量系統(tǒng)就是針對送風系統(tǒng)耗 電缺點的節(jié)能對策。然而這兩者在送風系統(tǒng)上浪費了大量能源。常用的中央空調系統(tǒng)為 AHU(空調機 )與冷水管系統(tǒng) FCU系統(tǒng)。這兩者一般均以定風量 (CAV)來供應空調區(qū),為了應付室內部分負荷的變動,在 AHU定風量系統(tǒng)以空調機的變溫送風來處理,在一般FCU系統(tǒng)則以冷水閥 ON/ OFF控制來調節(jié)送風溫度。當空調區(qū)域負荷變動時,則以改變送風溫度應付室內負荷,并達到維持室內溫度于舒適區(qū)的要求。 1定風量系統(tǒng) (ConstantAirVolume,簡稱 CAV)。 DDC(Directdigitalcontr01)直接數(shù)字化控制,是一項構造簡單操作容易的控制設備,它可借由接口轉接設備隨負荷變化作系統(tǒng)控制,如空調冷水循環(huán)系統(tǒng)、空調箱變頻自動風量調整及冷卻水塔散熱風扇的變頻操控等,可以讓空調系統(tǒng)更有效率的運轉,這樣,不僅為物業(yè)管理帶來很大的經(jīng)濟效益,而且還可使系統(tǒng)在較佳的工況下運行,從而延長設備的使用壽命以及達到提供舒適的空調環(huán)境和節(jié)能之目的 。特別是冷:東機組、冷卻塔、循環(huán)水泵和空調機組、新風機組,都是耗能大戶。 基于動態(tài)負荷跟蹤的中央空調系統(tǒng)全閉環(huán)節(jié)能技術的研究 1.引言 節(jié)能可以說是樓字自動控制系統(tǒng)的出發(fā)點和歸宿。 如果它隔離得好,沒有對變冷水系統(tǒng)的管的長度的實際的限制。 它把水冷卻到在 40 和 45 F( 和 C)之間。 在這點上,就該考慮一個變冷水的系統(tǒng)了。 變冷水的系統(tǒng) 在大的建筑,特別是在多層的大樓,變冷水的系統(tǒng)分析法開始遇到問題。 或者,在屋頂上可能有很多更小的單位,每一個里面附帶一臺