【正文】
3 4 5 6 Total總計(jì) 五、對(duì)施工圖紙的要求如下:V. Requirements for construction drawings are as follows: 用于設(shè)計(jì)方案階段的一套完整的圖紙至少應(yīng)包括封面、圖紙目錄、工程設(shè)計(jì)說(shuō)明及圖例、設(shè)備材料清單、系統(tǒng)圖、平面圖。(用EXCEL表格做出,格式如下,第一行內(nèi)容為示范)。II. Provide sound pressure level of direct sound (Direct SPL), total sound pressure lever (Total SPL) in each area (including the queue area, rehearse area and performance area).三、提交擴(kuò)聲系統(tǒng)中所采用設(shè)備的說(shuō)明書(shū)。When special or customized lightings are used, the detail drawing of installation shall be used to introduce the installation method of these lightings. The detail drawing of installation shall include the equipment installation and mounting form, equipment dimension, material name, model and specification, designed use quantity in each detail drawing, opening/hole dimension, connecting terminal drawing, color and serial number of connection, cable model, cable specification, loop No. and explanatory notes. 擴(kuò)聲Sound reinforcement 擴(kuò)聲專業(yè)施工圖設(shè)計(jì)深度標(biāo)準(zhǔn)及技術(shù)深度文件的標(biāo)準(zhǔn)擴(kuò)聲部分現(xiàn)規(guī)定如下:The design depth of sound reinforcement working drawing and the standard sound reinforcement part in the technical scope documents are specified as follows: 一、提供各區(qū)域(包括排隊(duì)區(qū)、預(yù)演區(qū)、主演區(qū))擴(kuò)聲系統(tǒng)形式:使用單聲道、立體聲或者環(huán)繞聲擴(kuò)聲。The detail drawing of installation is the explanatory drawing which defines the relationship between lighting installation and the structure.當(dāng)采用一些特殊形式或定制燈具時(shí)采用安裝大樣圖來(lái)介紹這些燈具的安裝方法。The controlling box and cabinet inside the equipment room shall be marked with the dimension, spacing and equipment type.(4)機(jī)房布置圖應(yīng)注明機(jī)房空間內(nèi)各設(shè)備安裝位置、相互關(guān)系及安裝工藝要求。The equipment room arrangement drawing shall include the plane layout and partial elevation of the power distributing cabinet and controlling box, giving clear indication of the trend of pipelines and trunking, explanatory notes, and so on.(2)平面圖上的設(shè)備位置、數(shù)量、編號(hào),纜線規(guī)格、管線與線槽走向應(yīng)與立面圖上的設(shè)備位置、數(shù)量、編號(hào),纜線規(guī)格、管線與線槽走向相對(duì)應(yīng)。To restrain the interference of ultraharmonics on illumination control devices and other system equipments, except that the regulations of Section , Chapter 22 of JGJ 162008 Code for Electrical Design of Civil Buildings shall be met, shall conform to the following requirements: the loop that needs light control shall select metal conduit and trunking for layup, and parallel layup of electroacoustics etc. telemunication lines is not suitable. When lightcontrolling loop are in parallel layup with telemunication lines, the distance shall be more than 1m。Trend of pipelines in the drawing shall consider the site operation conditions and provide convenience for future repair and maintenance, and shall be the same as the actual pipeline trend as much as possible.,除應(yīng)滿足《民用建筑電氣設(shè)計(jì)規(guī)范》JGJ ,還應(yīng)滿足以下要求:需要調(diào)光的回路應(yīng)選用金屬導(dǎo)管、槽敷設(shè),并不宜于電聲等電信線路平行敷設(shè)。 in particular, lighting fixtures with gas discharge lamp as the illuminant shall not be connected with the lighting fixtures using other illuminants in the same loop. ,且是否回路連接的負(fù)荷總量與配電箱系統(tǒng)圖上標(biāo)明的相符。Sockets shall not be connected with lighting equipment in the same loop. ,特別是以氣體放電燈為光源的燈具不要和其他類型光源的燈具接在同一回路上。 section of branch line shall not be smaller than . 。 current of the singlephase subcircuit connecting high capacity gas discharge lamp shall not exceed 30A. ,應(yīng)采用銅芯絕緣電線或電纜。Current of each singlephase subcircuit for lighting shall not exceed 16A, and there shall be less than 25 illuminants。For details, please refer to chapter 8 of JGJ 162008 Code for Electrical Design of Civil Buildings and chapter 7 of GB 500342004 Standard for Lighting Design of Buildings.以下所述在設(shè)計(jì)時(shí)應(yīng)特別注意:Special attention shall be paid to the following during design: 、編號(hào)、平面位置、安裝高度、安裝方式,管線、線槽走向、管線規(guī)格,敷設(shè)方式、引上引下、圖例、數(shù)量、文字說(shuō)明等。When marking the trunking, the model, specification and laying method shall be clearly distinguished.Piping plan具體設(shè)計(jì)原則請(qǐng)參考《民用建筑電氣設(shè)計(jì)規(guī)范》JGJ 162008第8章。According to the trend, special lighting trunking can usually be divided into: horizontal trunking and vertical trunking. According to the system, special lighting trunking can usually be divided into: integrated trunking for lightcurrent control signal lines and trunking for strongcurrent cables. Trunking for strongcurrent and lightcurrent shall be set respectively and shall not be shared. For detailed principles for design, please refer to chapter 8 of JGJ 162008 Code for Electrical Design of Civil Buildings. ,原則上應(yīng)按線槽實(shí)際寬度按圖紙比例繪制,線槽截面應(yīng)采用空心閉合圖形。強(qiáng)、弱電線槽應(yīng)分別設(shè)置,不允許共用。The electric wiring drawn from vertical shaft for lightcurrent and strongcurrent or control cabinet shall adopt trunking when there are numerous loops. :水平線槽、垂直線槽。Other detailed design criteria shall conform to the relevant requirements about electricity and lighting in China39。電影院建筑設(shè)計(jì)規(guī)范187。Lightcontrolling equipments and pipelines shall be conveniently installed and laid.Plan viewGeneral requirements (1)照明配電箱宜設(shè)置在靠近照明負(fù)荷中心便于操作維護(hù)的位置。 (3)燈控人員應(yīng)能容易的觀察到觀眾席的情況;Lightcontrolling personnel shall be able to easily observe the auditorium。 for the theater with middle size and above, the controller with puter could be selected.2. 舞臺(tái)照明調(diào)光控制臺(tái)宜安裝在觀眾廳后部的燈控室內(nèi),并應(yīng)符合下列規(guī)定:Stage illumination lighting console shall install in the lighting control room in the back of auaditorium and conform to the following regulations:(1)調(diào)光柜和舞臺(tái)配電設(shè)備應(yīng)設(shè)在靠近舞臺(tái)的單獨(dú)房間內(nèi);Dimmer cabinet and stage distribution equipment shall be set up within the single room close to the stage。When using the lightcontrolling devices, the load capacity for each lighting loop shall be patible with the output capacity of the selected lightcontrolling device.:The selection and installation of stage lightcontrolling devices withpersonnel’s participation in the stage show in the likelytobe 5D theatershall conform to the follwing requirements:1. 舞臺(tái)照明調(diào)光控制器的選型:小型劇場(chǎng),可選用帶預(yù)選裝置的控制器,中型及以上規(guī)模的劇場(chǎng),宜選用帶計(jì)算機(jī)的控制器。Lighting in the audience hall of class B or above cinemas (performance area and rehearse area) shall be capable of changing from bright to dim stat