【正文】
The workstation wiring shall be placed in a 1 inch 25mm conduit that is home run from ea。 Each workstation is to be wired to acmodate one (1) fourpair 24gauge Category 6 Inside Wire for voice, and one (1) fourpair 24gauge Category 6 Inside Wire for data. Termination must be in a fourway flush mount faceplate.每個(gè)工作站的布線應(yīng)敷設(shè)一(1)根4 對(duì)雙絞的24 號(hào)六類(lèi)室內(nèi)語(yǔ)音線和一(1)根4 對(duì)雙絞的24 號(hào)六類(lèi)室內(nèi)數(shù)據(jù)線。B. One 20 amp duplex receptacle for miscellaneous items.一個(gè)供其他設(shè)備使用的20 安雙聯(lián)框插座。 Provide a minimum of one 20 amp duplex receptacle on each wall with spacing not to exceed 20 feet (6m) on center.每面墻壁應(yīng)至少安裝一個(gè)20 安的雙聯(lián)框插座,中心距不超過(guò)6 米。 Provide dimmable incandescent and fluorescent lighting in the training room capable of providing sixty (60) footcandles (645 lux)of general lighting measured at table height.應(yīng)為培訓(xùn)室安裝可調(diào)光的白熾燈和熒光燈,在桌面高度總照度至少應(yīng)達(dá)到六十(60)英尺燭光(645 勒克斯)。 ELECTRICAL 電氣 Provide a minimum of sixty (60) footcandles (645 lux)of general lighting in the office areas. Lighting level is to be measured at desk height.辦公室區(qū)的總照度至少應(yīng)達(dá)到六十(60)英尺燭光(645 勒克斯)。 Provide a ceiling mounted 27‖ () LCD HDTV with Multi system VCR and Multi region DVD in training room.在培訓(xùn)室提供天花板吊裝式27 英寸( 米)液晶高清電視,并配備多制式錄像機(jī)和多區(qū)DVD 播放機(jī)。E) for offices must be approved by Hilton Hotels Corporation.辦公室所需的辦公用品及設(shè)備 (OSamp。 Operational Supplies amp。 FINISHES 飾面 OFFICE:辦公室:Floors Carpet / Carpet Tile地面 地毯 / 小方地毯Base 4 (10cm) Vinyl Cove Base / Carpet / Wood墻踢腳 10 厘米乙烯弧形 / 地毯 / 木材Walls Vinyl Wall Covering / Paint墻面 乙烯墻面涂料/涂刷Ceiling Acoustic tile天花板 隔音磚 TRAINING ROOM:培訓(xùn)室:Floors Carpet / Carpet Tile地面 地毯 / 小方地毯Base 4 (10 cm) Vinyl Cove Base / Carpet墻踢腳 10 厘米乙烯弧形 / 地毯Walls Vinyl Wall Covering墻面 乙烯墻布Ceiling Acoustic tile天花板 隔音磚 FFamp。A. Directors office 12‘0‖ x 10‘0‖ ( x 3m)主管辦公室 米 x 3 米B. Clerk‘s office 12‘0‖ x 10‘0‖ ( x 3m)文員辦公室 米 x 3 米C. Work cubicle 6‘0‖ x 6‘0‖ ( x )工作間 米 x 米 DOORS, WINDOWS and HARDWARE 門(mén)、窗和五金件 Install a window, borrowed light or glazed door in the personnel office to facilitate visual supervision of the employees39。 Partitions surrounding the training room shall have an acoustical rating of STC55 and extend to the underside of the structure above.為需要封閉的培訓(xùn)室安裝的隔墻應(yīng)有STC 55 的隔聲等級(jí),并延伸至上方結(jié)構(gòu)的底部。 Provide a training room with the minimum of 325 square feet (30m) adjacent to the clerk‘s office.在文員辦公室附近設(shè)置一個(gè)面積最小為30 平方米的培訓(xùn)室。s office for at least two applicants to fill out application forms. Provide additional waiting space in the general vicinity of the personnel office for 4 to 6 applicants.文員的辦公區(qū)域應(yīng)至少可供兩位申請(qǐng)人填寫(xiě)申請(qǐng)表格。 The personnel office must have an open office area for the personnel clerk and an enclosed office for the director of human resources.人事辦公室必須設(shè)一個(gè)文員使用的敞開(kāi)式辦公區(qū)和一個(gè)人力資源主管使用的封閉式辦公室。人事辦公室所處的位置必須方便員工快速通達(dá),無(wú)需穿過(guò)接待人流。第4e 節(jié) 人事辦公室 GENERAL 總則 In smaller hotels the personnel offices should be located at the employees‘ entrance with visual supervision of the employees39。 Provide one 240v. 40 amp receptacle on a dedicated circuit for the copier.在專用電路中提供一個(gè)240 伏40 安的插座供復(fù)印機(jī)使用。集線器至每個(gè)工作站的最大距離為90 米。 Each workstation is to be wired to acmodate one (1) fourpair 24gauge Category 6 Inside Wire for voice, and one (1) fourpair 24gauge Category 6 Inside Wire for data.每個(gè)工作站的布線應(yīng)敷設(shè)一(1)根4 對(duì)雙絞的24 號(hào)六類(lèi)室內(nèi)語(yǔ)音線和一(1)根4對(duì)雙絞的24 號(hào)六類(lèi)室內(nèi)數(shù)據(jù)線。B. One, 20 amp duplex receptacle for miscellaneous items.一個(gè)供其他設(shè)備使用的20 安雙聯(lián)框插座。 Provide a minimum of one, 20 amp duplex receptacle on each wall with spacing not to exceed 20 feet (6m) on center.每面墻壁應(yīng)至少安裝一個(gè)20 安的雙聯(lián)框插座,插座之間的中心距不超過(guò)6米。應(yīng)在桌面高度測(cè)量照度。 Where HVAC units are located directly over office areas provide sound attenuation.如果暖通空調(diào)系統(tǒng)直接安裝在辦公區(qū)域上方,則應(yīng)設(shè)置消聲裝置。 SPECIAL CONSTRUCTION (Graphics and Signs) (NA) 特殊結(jié)構(gòu)(圖形和標(biāo)志)(不適用) MECHANICAL / PLUMBING 機(jī)械/管道 Provide a single thermostat for each office suite. Separate controls are not required for individual offices.每個(gè)辦公室套間配備一個(gè)獨(dú)立的溫控器。E) for offices must be approved by Hilton Hotels Corporation.辦公室所需的辦公用品及設(shè)備 (OSamp。 Operational Supplies amp。 FFamp。 Doors facing public spaces must plement the interior design of that space.對(duì)著公共區(qū)的門(mén)必須能為該區(qū)的室內(nèi)設(shè)計(jì)增色。 Provide locksets with pushbutton lock on all rooms and offices. Pushbutton lock must release with a key, by turning the inside lever and/or by closing the door.所有的房間和辦公室都安裝按鍵鎖。6 x 639。A. Directors office 12‘0‖ x 10‘0‖ ( x 3m)主管辦公室 米 x 3 米B. Managers office 10‘0‖ x 8‘0‖ (3 x )經(jīng)理辦公室 3 米 x 米C. Work cubicle 6‘0‖ x 6‘0‖ ( x )工作間 米x 米 Office to have a clear ceiling height of 8‘6‖ () 米。 Partitions surrounding the required enclosed offices shall have an acoustical rating of STC50 and extend to the underside of the structure above.為需要封閉的辦公室安裝的隔墻應(yīng)有STC 50 的隔聲等級(jí),并延伸至上方結(jié)構(gòu)的底部。 When the administrative offices are consolidated into a single suite, open office planning may be considered.如果將行政辦公室合并到一個(gè)單獨(dú)的套間,則可考慮開(kāi)放式辦公規(guī)劃方案。第4d 節(jié) 財(cái)務(wù)室 GENERAL 總則 The accounting office should, whenever possible, be consolidated with all other administrative offices and located behind or adjacent to the registration desk.財(cái)務(wù)室應(yīng)盡量和其他行政辦公室集中在一起,位于登記臺(tái)后面或鄰近處。 Provide one 240v. 40 amp receptacle on a dedicated circuit for the copier.在專用電路中提供一個(gè)240 伏40 安的插座供復(fù)印機(jī)使用。集線器至每個(gè)工作站的最大距離為90 米。 Each workstation is to be wired to acmodate one (1) fourpair 24gauge Category 6 Inside Wire for voice, and one (1) fourpair 24gauge Category 6 Inside Wire for data.每個(gè)工作站的布線應(yīng)敷設(shè)一(1)根4 對(duì)雙絞的24 號(hào)六類(lèi)室內(nèi)語(yǔ)音線和一(1)根4 對(duì)雙絞的24 號(hào)六類(lèi)室內(nèi)數(shù)據(jù)線。B. One 20 amp. duplex receptacle for miscellaneous items.一個(gè)供其他設(shè)備使用的20 安雙聯(lián)框插座。 Provide a minimum of one 20 amp duplex receptacle on each wall with spacing not to exceed 20 feet (6m) on center.每面墻壁應(yīng)至少安裝一個(gè)20 安的雙聯(lián)框插座,插座之間的中心距不超過(guò)6米。必須在桌面高度測(cè)量照度。 Where HVAC units are located directly over office areas, provide sound attenuation.如果暖通空調(diào)系統(tǒng)直接安裝在辦公區(qū)域上方,則應(yīng)設(shè)置消聲裝置。 SPECIAL CONSTRUCTION (Graphics and Signs) (NA) 特殊結(jié)構(gòu)(圖形和標(biāo)志)(不適用) MECHANICAL / PLUMBING 機(jī)械/管道 Provide a single