【正文】
function activated 0 = Priority function activated。 1 = Priority function deactivated Emission of the “Priority function status” object : On change, Periodically, On change and periodically Time for periodical emission of priority status object: H, Min , Sec Position after priority : Unchanged, UP, Down, specific position, Scene X, Position before priority function, Theoretical position after priority function Unchanged , Invert status, ON, OFF, Status before manual mode, Theoretical status after priority Unchanged , Invert status, ON, OFF, Value %, Status before manual mode, Theoretical status after priority Priority function Priority Priority function status 優(yōu)先級控制:參數(shù)詳解 Erdal Y252。zer New Generation Step 1 35 LockUp LockUp鎖定應用場合 ? 用于通過一個高優(yōu)先級的命令鎖定一個輸出的普通控制功能 ? 鎖定期間忽略給該對象的普通控制信號 Logic Block邏輯塊應用場合 ? 通過比較不同的 1bit信號源,計算出一個需要的邏輯結果 ? 一個模塊含有 2個邏輯塊( 2 logic blocks / device) ? 一個邏輯塊至多有 4個邏輯輸入 Erdal Y252。zer New Generation Step 1 36 鎖定:參數(shù)詳解 Activation of lockup function: Not used Used with 1 Lockup object Used with 2 Lockup objects Lockup function type : Output lockup, Object lockup Lockup function duration: Permanent, time limited Duration of lockup function: h, min , s Position during Lockup function 1/2: Unchanged, Stop, UP, Down, Specific position Unchanged , Invert status, ON, OFF Unchanged , Invert status, ON, OFF, Value % Objects authorized by Lockup function 1/2: Up/Down, Step/stop, Scene, Position %, Slat angle %, Sun protection position %, Sun protection slat angle %, Preset 1, Preset 2 ON/OFF, Scene, Timer, Timer / toggle change over, Time limited toggle switch, Preset 1, Preset 2 ON/OFF, Dimming, Brightness value %, Scene, Timer, Timer / toggle changeover, Time limited toggle switch, Preset 1, Preset 2 Polarity of Lockup object 1/2: “0” = Lockup disabled, “1” = Lockup Enabled “0” = Lockup enabled, “1” = Lockup disabled Priority between Lockup 1 and Lockup 2 function: Lockup 1 Lockup 2 Lockup 1 Lockup 2 Lockup 1 = Lockup 2 Activation of Lockup function status object: Enabled, Disabled Polarity of Lockup function status object: “0” = Lockup function deactivated, “1” = Lockup function activated” “0” = Lockup function activated, “1” = Lockup function deactivated” Emission of Lockup function status object: On change, Periodically, On change and periodically Time for periodical emission of the “Lockup function status” object: H, Min, Sec Position after lockup 1/2: Unchanged, Up, Down, Specific position, Position before Lockup function, Theoretical position after Lockup function Unchanged, inverted, ON, OFF Status before lockup function, Theoretical status after Lockup function Unchanged, inverted, Value %, Status before lockup function, Theoretical status after Lockup function Lockup function Lockup 2 Lockup 1 Lockup status Erdal Y252。zer New Generation Step 1 37 邏輯塊:參數(shù)詳解 Activation of logic block 1/2: Used, Not used Function of logic block 1/2: OR, AND Number of logical inputs of Logic block 1/2: 1, 2, 3, 4 Inverting value of Logic input 1/2/3/4 : Not inverted, inverted Value of logic input 1/2/3/4 after bus return : 0, 1 Activation of logic block 1/2 authorization object: Used, Not used Polarity of logic block 1/2 authorization object: “0” = Not authorized, “1” = Authorized “0” = Authorized, “1” = Not authorized Logic result treatment if Logic bloc 1/2 authorized: Send/evaluate logic result immediately。 Send/evaluate logic result after next telegram ining on logic input Emission of the logic result object: Send object at each logic input value change, Send object at each logic result value change Chaining of logic result of Logic block 1/2: Not used, Used Output 1..10 controlled by logic result of logic block 1/2: Yes, No Position if logic result of logic block 1/2 = “0”: Unchanged, UP, Down, Stop, Specific position, Scene X, Preset 1, Preset 2 Unchanged, Invert status, ON, OFF, Timer start, Timer stop, Scene, Preset 1, Preset 2 Unchanged, Invert status, ON, OFF, Value %, Timer start, Timer stop, Scene, Preset 1, Preset 2 Position if logic result of logic block 1/2 =“1”: Unchanged, UP, Down, Stop, Specific position, Scene X, Preset 1, Preset 2 Unchanged, Invert status, ON, OFF, Timer start, Timer stop, Scene, Preset 1, Preset 2 Unchanged, Invert status, ON, OFF, Value %, Timer start, Timer stop, Scene, Preset 1, Preset 2 Logic blocs (x2) Logic result Author. logic Logic input 1 Logic input 3 Logic input 2 Logic input 4 Erdal Y252。zer New Generation Step 1 38 課堂練習題 按鍵 1開閉 output1(開關),按鍵 2Lockup output1 只有當 output1處于 Lockup狀態(tài)時,開啟按鍵 3時,可以開啟 output output output6(開關) 將下面的邏輯形式通過編程表現(xiàn)出來 主人回家,需要刷卡進門,當走廊的探測器發(fā)現(xiàn)有人經(jīng)過時,且走廊上光線較暗,則開啟燈光,若主人未刷卡,則探測器一旦發(fā)現(xiàn)有人經(jīng)過,則自動報警 目的: 熟悉 Lockup和基本的 Logic功能。 熟練運用模塊自帶的 Logic Block Erdal Y252。zer New Generation Step 1 39 電流檢測 設備當前運行狀態(tài)顯示 可設定警報電流閥值 可設定峰值報警 可設定電流中斷報警 (中斷超過 6小時) 當前電流值測量 漏電檢測 Erdal Y252。zer New Generation Step 1 40 課堂練習題 檢測當有燈泡虛接時(測試時將燈泡斷開)發(fā)出報警,報警信號為另一個開關模塊 output1閃爍。 測試當短時斷電后,是否會有報警信號,設置短時斷電時間為 2min,觀察 Group Monitor/Bus Monitor有何變化,并讀懂 Bus Monitor數(shù)據(jù) 目的: 熟悉電流檢測的基本應用。 復習 Group Monitor/Bus Monitor的使用 Erdal Y252。zer New Generation Step 1 41 Thank You 2023 演講完畢,謝謝觀看!