【文章內(nèi)容簡(jiǎn)介】
7 中性點(diǎn)隔離開(kāi)關(guān) ......................................................................................... 69 電流互感器的選擇 ..................................................................................................... 70 110kV 側(cè)電流互感器的選擇 ........................................................................ 70 35kV 側(cè)電流互感器的選擇 ........................................................................ 71 10kV 側(cè)電流互感器的選擇 ........................................................................ 72 中性 點(diǎn)電流互感器的選擇 ......................................................................... 73 電壓互感器的選擇 ..................................................................................................... 74 110kV 側(cè)電壓互感器的選擇 ........................................................................ 74 35kV 側(cè)電壓互感器的選擇 .......................................................................... 75 10kV 側(cè)電壓互感器的選擇 .......................................................................... 75 高壓熔斷器的選擇 ..................................................................................................... 75 35kV 側(cè)熔斷器的選擇 .................................................................................. 75 10kV 側(cè)熔斷器的選擇 .................................................................................. 76 避雷器的選擇 ............................................................................................................. 77 110kV 側(cè)避雷器的選擇 ................................................................................ 77 35kV 側(cè)避雷器的選擇 .................................................................................. 77 10kV 避雷器的選擇 ...................................................................................... 78 消弧線圈的選擇 ....................................................................................................... 78 無(wú)功補(bǔ)償?shù)挠?jì)算 ..................................................................................................... 79 第 11 章 主變壓器保護(hù)的整定計(jì)算 ......................................................................................... 79 變壓器瓦斯保護(hù)整定 ............................................................................................... 79 變壓器差動(dòng)保護(hù)整定計(jì)算 ....................................................................................... 80 變壓器 復(fù)合電壓 啟動(dòng)的 過(guò) 電 流保護(hù) ............................................................... 83 IV 35kV 側(cè)復(fù)合電壓?jiǎn)?dòng)的過(guò)電流保護(hù) .......................................................... 83 變壓器接地短路的后備保護(hù) 零序電流保護(hù) ................................................. 84 異常運(yùn)行保護(hù) 過(guò)負(fù)荷保護(hù)的整定 ................................................................. 85 致 謝 ........................................................................................................................................... 87 17137 降壓變電站 ( 110/35/10kV)電氣部分初步設(shè)計(jì) 摘 要 本次設(shè)計(jì)為 17137 地區(qū)性降壓變電站 110/35/10kV電氣部分初步設(shè)計(jì) ,該變電站是為了滿足該地區(qū)的供電需要,提高對(duì)用戶供電的可靠性和電能質(zhì)量所建設(shè)的一所區(qū)域性降壓變電站,該變電站高壓側(cè)與系統(tǒng)相連,中壓側(cè)、低壓側(cè)只有出線負(fù)荷。 本次設(shè)計(jì)是對(duì)變電站電氣一次部分的設(shè)計(jì)及電氣二次的初步設(shè)計(jì),設(shè)計(jì)過(guò)程可以通過(guò)對(duì)該變電站的原始資料分析首先確定變電站的電氣主接線及主變壓器型號(hào),然后根據(jù)電氣主接線進(jìn)行短路點(diǎn)的選擇并進(jìn)行短路電流計(jì)算,根據(jù)短路電流計(jì)算結(jié)果并依據(jù)變電站設(shè)計(jì)規(guī)范、參考有關(guān)電力工程設(shè)計(jì)手冊(cè),按照目前電力系統(tǒng) 工程設(shè)計(jì)的新思路來(lái)選擇設(shè)備,并進(jìn)行校驗(yàn)。 設(shè)計(jì)的主要內(nèi)容包括:電氣主接線設(shè)計(jì)、短路電流計(jì)算、電氣設(shè)備選擇與校驗(yàn)(包括變壓器的選擇、斷路器及隔離開(kāi)關(guān)的選擇和校驗(yàn)、導(dǎo)體的選擇與校驗(yàn)、電流互感器及電壓互感器的選擇與校驗(yàn)等)、主變壓器保護(hù)配置、配電裝置設(shè)計(jì)。 關(guān)鍵詞 :變壓器 。電氣設(shè)備 。電氣主接線 。短路電流 V The Preliminary Design of the Electrical Part of Regional Stepdown Substation(110/35/10kV) Abstract This design is the electricity one of the 110/35/10kV dropping transformer substation. The transformer substation is built to meet the need for the load, and to improve the reliability and the electrical energy quality. And the high side of this transformer is connected with the system, but the middle voltage side and the low voltage side only has the load. This design is the electric preliminary design of the transformer substation. Through the analysis of firsthand information, I determine the main wiring and style of the main transformer and choice the dot of the shortcircuit, and make shortcircuit calculation, and basing on that and the standard of the transformer substation design, the reference related to the electric power project design hand book, and according to the new mentality of the electrical power system engineering design at president, I make the check. The design mainly includes: main electrical wiring design, the calculation of the shortcircuit, the choose and the check of the elect equipment ( including transformer, line breaker, busbar, current transformer, tension transformer and so on), and the design of the setting equipment. Key words: transformer ,electric equipment ,main electrical wiring, shortcircuit current 1 第一部分 設(shè) 計(jì)說(shuō)明書(shū) 第 1章 概述 變電站的作用 變電站是聯(lián)系發(fā)電廠和用戶用電設(shè)備的中間環(huán)節(jié),一般安裝有變壓器及其控制和保護(hù)裝置,其作用是變換和分配電能。 此次所設(shè)計(jì)的變電站是一座 110kV降壓變電站,是為了滿足該地區(qū)鄉(xiāng)鎮(zhèn)負(fù)荷日益增長(zhǎng)的需要,同時(shí)也是為了提高對(duì)用戶供電的可靠性和電能質(zhì)量所建設(shè)的一所 110/35/10 kV 區(qū)域性降壓變電站。 待建變電站的主要技術(shù)指標(biāo)及參數(shù) 1. 為滿足鄉(xiāng)鎮(zhèn)負(fù)荷日益增長(zhǎng)的需要,提高對(duì)用戶供電的可靠性和電能質(zhì)量,根據(jù)電力系統(tǒng)發(fā)展規(guī)劃,擬建設(shè)一座 110/35/10kV 的區(qū)域性降壓變電所。 2. 擬建 變電站在城市近郊,在變電站附近有地區(qū)負(fù)荷。 110kV 以雙回路與 140km外的系統(tǒng)相連。系統(tǒng)最大方式的容量為 1600 MVA,相應(yīng)的系統(tǒng)電抗為 ;系統(tǒng)最小方式的容量為 800 MVA,相應(yīng)的系統(tǒng)電抗為 (系統(tǒng)容量及電壓為基準(zhǔn)的標(biāo)么值)。 3. 35kV 電壓級(jí) 重要負(fù)荷為 64%, cosΦ= 。 架空線 6回, 3 回輸送距離 40km,每回輸送功率 5MVA; 3回輸送距離 20km,每回輸送功率 6MVA。 4. 10kV 電壓級(jí) 重要負(fù)荷為 60%, cosΦ= 。 電纜出線 6 回,每回輸送距離 3km,輸送功率 ;架空輸電線 4 回,輸送距離 7km,每回輸送功率 。 5. 本站屬新建變電站,周圍無(wú)大污染源,處于系統(tǒng)環(huán)式主干網(wǎng)上,在 110kV 側(cè)有明顯的穿越功率,該變電站一旦停電,不但對(duì)本地區(qū)工農(nóng)業(yè)生產(chǎn)造成很大的影響,而且影響全系統(tǒng)的安全運(yùn)行,所以系統(tǒng)對(duì)本站的運(yùn)行要求程度很高。 35kV 和 10kV 用戶負(fù)荷的 最大負(fù)荷利用小時(shí) Tmax= 5300h, 同時(shí)系數(shù) 35kV 取 , 10kV 取 , 35kV 各負(fù)荷與 10kV 各負(fù)荷之間取 。 2 6. 變電站所在地區(qū)海拔 150m 地勢(shì)平坦,為非強(qiáng)地震區(qū),輸電 線路走廊闊,架設(shè)方便,全線為黃土層地帶,地耐力為 ,天然容重γ =2g/cm,內(nèi)摩擦角θ =23186。,土壤電阻率為 130Ω cm,地下水位較低,水質(zhì)良好,無(wú)腐蝕性。氣象條件:年最高氣溫+ 40℃, 年最低氣溫- 8℃, 年平均溫度+ 16℃, 最熱月平均最高溫度+ ℃, 最大復(fù)水厚度 b=10cm,最大風(fēng)速 25m/s,屬于我國(guó)第六標(biāo)準(zhǔn)氣象區(qū)。 第 2 章 主變壓器的選擇 主變壓器容量、臺(tái)數(shù)的選擇 主變壓器臺(tái)數(shù)的選擇 為了保證供電可靠性,避免一臺(tái)主變壓器故障或檢修時(shí)影響供電,變電所一般裝設(shè)2 臺(tái)主 變壓器,但一般不超過(guò) 2 臺(tái)變壓器。對(duì)于大型樞紐變電所,裝設(shè)兩臺(tái)大型變壓器,當(dāng)一臺(tái)發(fā)生故障時(shí),