20xx畢業(yè)設(shè)計(jì)-煙臺(tái)市東方賓館進(jìn)行中央空調(diào)系統(tǒng)設(shè)計(jì)及通風(fēng)設(shè)計(jì)含圖紙(完整版)

  

【正文】 the prehensive ventilation, and central airconditioning system design of Dongfang Hotels. The building is located in Yantai. The earas is about 18,000 square meters and the height is meters. Underground 1 includes garage,storagy,refrigeration room and pump first floor is prised by twostory atrium, offices, restaurants ,kitchen,business center and shopping rooms. There are coffee room, On the 310 level are the rooms and height of the frist floor and the second floor is meters, whears the others height is . The design is focus on the central airconditioning system design and the ventilation of the underground. According to the function room and the design requirements, there are two preject being adopted, the fan disk pulsing new wind and returnd cycle air system. The design project of water system is different programming system. The air conditioning system, the calculation of cold and heat load, the selection of airconditioning, duct hydraulic calculation and the layout, room air distribution, pipelines muffler resistance and thermal design are thought over. The water system division, plumbing and hydraulic calculation of the layout of pipes, pumps and fan choice, ventilation and airconditioning system, and the automatic control were also designed. Keywords: central airconditioning system。 1 目 錄 圖紙聯(lián)系 153893706 摘要 ???????????????????????????? Ⅳ ABSTRACT ??????????????????????? Ⅴ 前言 ???????????????????????????? 1 正文 1 工程概況 ??????????????????????? 2 工程概況 ????????????????????? 2 原始資料 ????????????????????? 2 室外氣象參數(shù) ??????????????? 2 建筑結(jié)構(gòu) ????????????????? 2 2 設(shè)計(jì)方案論證 ????????????????????? 3 空調(diào)方案 ???????????????????? 3 水系統(tǒng)布置 ??????????????????? 4 兩管系統(tǒng)的優(yōu)點(diǎn) ?????????????? 4 閉式系統(tǒng)的優(yōu)點(diǎn) ?????????? ???? 4 同程和異程系統(tǒng)的選擇 ??????????? 4 定流量和變流量系統(tǒng) ???????????? 5 風(fēng)系統(tǒng)布置 ?????????????????? 5 3 空調(diào)負(fù)荷計(jì)算 ????????????????????? 6 基本氣象參數(shù) ?????????????????? 6 冷負(fù)荷計(jì)算 ??????????????????? 6 熱負(fù)荷 計(jì)算 ??????????????????? 11 2 4 房間的空氣處理方案及送風(fēng)量的確定 ??????????? 16 房間空氣處理過(guò)程 ???????????????? 16 送風(fēng)量的確定 ?????????????????? 16 5 風(fēng)機(jī)盤(pán)管、新風(fēng)機(jī)組的選擇 ??????????????? 18 風(fēng)機(jī)盤(pán)管的選擇 ????????????????? 18 新風(fēng)機(jī)組的選擇 ????????????????? 20 6 氣流 組織方式的選擇 ?????????????????? 21 概述 ?????????????????????? 21 常用空調(diào)氣流組織方式 ?????????????? 21 房間氣流組織方式 ???????????????? 22 氣流組織計(jì)算和風(fēng)口選擇 ????????????? 22 7 系統(tǒng)水力計(jì)算 ????????????????????? 23 風(fēng)系統(tǒng)水力計(jì)算 ????????????????? 23 通風(fēng)管道的設(shè)計(jì)原則 ??????????? 23 通風(fēng)管道的選擇 ????????????? 23 通風(fēng)管道的制作 ????????????? 23 送風(fēng)管尺寸的確定 ???????????? 23 回、排風(fēng)管尺寸的確定 ?????????? 30 管路平衡 ???????????????? 35 水系統(tǒng)水力計(jì)算 ????????????????? 37 冷凍水系統(tǒng)的選擇 ???????????? 37 冷凍水的水力計(jì)算 ???????????? 37 8 管道保溫 ??????????????????????? 41 3 風(fēng)管的保溫設(shè)計(jì) ???????????????? 41 冷凍水管的保溫設(shè)計(jì) ?????????????? 42 保溫材料的選擇 ???????????? ???? 42 選擇要求 ???????????????? 42 保溫材料 ???????????????? 43 施工過(guò)程中的注意事項(xiàng) ?????????? 43 9 系統(tǒng)消聲 ?????????????????????? 44 噪聲影響及采取的措施 ????????????? 44 消聲裝置的選擇 ???????????????? 44 消聲設(shè)計(jì)步驟 ????????????????? 46 10 系統(tǒng)減振 ??????????????????? ??? 46 11 防排煙系統(tǒng)設(shè)計(jì)及衛(wèi)生間排風(fēng) ????????????? 47 防排煙系統(tǒng)設(shè)計(jì) ???????????????? 47 防排煙方式及其應(yīng)用條件 ????????? 47 加壓送風(fēng)量的確定 ???????????? 48 衛(wèi)生間的排風(fēng)設(shè)計(jì) ??????????????? 49 結(jié)論 ???????????????????????? 50 謝辭 ?????????????? ?????????? 51 參考文獻(xiàn) ?????????????????????? 52 4 摘 要 本次畢業(yè)設(shè)計(jì)的主要內(nèi)容是對(duì)煙臺(tái)市東方賓館進(jìn)行中央空調(diào)系統(tǒng)設(shè)計(jì)及通風(fēng)設(shè)計(jì)。 ventilation design。特別是近十年來(lái),空調(diào)技術(shù)在我國(guó)得到空前發(fā) 展,從事空調(diào)行業(yè)的專業(yè)技術(shù)隊(duì)伍日益壯大,同時(shí),大量的空調(diào)設(shè)計(jì)資料也日益完善。防火設(shè)計(jì)的建筑分為兩類,其耐火等級(jí)為地上一級(jí),地下一級(jí);建筑物地下一層包括車庫(kù)、倉(cāng)庫(kù)、制冷機(jī)房、水泵房;一層包括大廳、商場(chǎng)、咖啡廳、餐廳、廚房、商務(wù)中心等;二層為浴室、按摩室、美容美發(fā)、餐廳包間等三至十層為客房,十一層為屋頂設(shè)備層??照{(diào)方案一旦確定就要進(jìn)行選型計(jì)算。地下一層為車庫(kù),也用作制冷機(jī)房,考慮人員滯留時(shí)間短,且各項(xiàng)冷負(fù)荷均較小,故僅做通風(fēng)。 9 本設(shè)計(jì)采用兩管制、閉式、水平異程、一次泵、變流量系統(tǒng)。 1)水泵揚(yáng)程僅需克服循環(huán)阻力,與樓層數(shù)無(wú)關(guān),僅取決于管路長(zhǎng)度和阻力。但同程系統(tǒng)的管材消耗量要多些。由于大樓層面積較大,水平管路布置采用異程式。變水量系統(tǒng)適應(yīng)于大 面積空調(diào)全年運(yùn)行的系統(tǒng)。見(jiàn)表 228 取 lst? = 2℃。 送風(fēng)量的確定 空調(diào)房間的總送風(fēng)量確定方法如下:由房間熱濕比 ε和選定的送風(fēng)溫差⊿ t 確定送風(fēng)狀態(tài)點(diǎn) O 點(diǎn),然后算出室內(nèi)狀態(tài)點(diǎn) N 點(diǎn)和送風(fēng)狀態(tài)點(diǎn) O 點(diǎn)之間的焓差( hn 21 ho),再用空調(diào)房間的室內(nèi)負(fù)荷除以以上算出的焓差即得空調(diào)房間的總送風(fēng)量 G。 名義制冷量:干球溫度 27℃ 濕球溫度 ℃ 冷凍水進(jìn)口溫度 7℃ 進(jìn)出口溫差 5℃ 采用臥式暗裝風(fēng)機(jī)盤(pán)管,高靜壓型的標(biāo)準(zhǔn)風(fēng)機(jī)盤(pán)管,在此前提下,按風(fēng)機(jī)盤(pán)管中檔風(fēng)量下制冷量進(jìn)行選型。 25 一層大餐廳、廚房分別設(shè)置一個(gè)新風(fēng)機(jī)組,二層浴室、餐廳包間各設(shè)一個(gè)新風(fēng)機(jī)組,三 — 十層每層各設(shè)一個(gè)新風(fēng)機(jī)組。對(duì)室溫允許波動(dòng)范圍有要求的空調(diào)房間的氣流組織常用前三種。孔板送風(fēng)可分為全面孔板和局部孔板送風(fēng)。 27 氣流組織計(jì)算和風(fēng)口選擇 選取有代表性的 房間(全空氣系統(tǒng))進(jìn)行氣流組織和風(fēng)口選擇的計(jì)算。 在風(fēng)管的選擇上,圓風(fēng)管的強(qiáng)度雖大, 耗鋼量雖小,但占有有效空間較大,不易布置且不美觀。由于矩形風(fēng)管占有效空間比較小,易于布置,明裝較美觀等特點(diǎn),故采用矩形風(fēng)管。/h) 風(fēng)管尺寸 (mm*mm) 實(shí)際流速 (m/s) 1 3 180 160*120 2 6 540 160*160 3 6 720 250*160 4 6 900 250*200 5 6 1080 320*160 6 6 1170 250*250 7 6 1200 250*250 8 6 2460 500*250 33 9 6 2640 400*320 14 6 1260 25*0250 管段 10 同管段 管段 11 同管段 管段 12 同管段 管段 13同管段 4 淋浴室 淋浴室要設(shè)立單獨(dú)的新風(fēng)系統(tǒng),并且一定要做排風(fēng),以保證室內(nèi)負(fù)壓。/h,全壓 100pa,轉(zhuǎn)速 930r/min 廚房排風(fēng)管布置: 廚房排風(fēng)主要是由局部排風(fēng)罩和集中排風(fēng)承擔(dān),其中局部排風(fēng)罩承擔(dān) 65%,集中排 35%,故集中排風(fēng)量為 Gp=179。/h,全壓 100pa,轉(zhuǎn)速 930r/min 二層?xùn)|側(cè)排風(fēng)管布置如下: 風(fēng)管尺寸如下: 管段編號(hào) 風(fēng)量 (m179。 冷凍水系統(tǒng)的選擇 根據(jù)回水方式的不同,空調(diào)水系統(tǒng)有重力式和壓力式兩種,本設(shè)計(jì)采用壓力式,為封閉式回水系統(tǒng)。為了實(shí)現(xiàn)水力平衡,在每層的水平管處設(shè)調(diào)節(jié)閥進(jìn)行水量調(diào)節(jié)。C; tj—— 供水的平均溫度, 取 7186。 冷凝水管管徑的確定 為方便計(jì)算,冷凝水管管徑可按末端設(shè)備的供冷量選用,見(jiàn)下表: 凝結(jié)水管管徑估算表 冷負(fù)荷 (kw) 10 1120 21100 101180 181600 DN 20 25 32 40 50 冷負(fù)荷 (kw) 601800 8011000 10011500 150112020 12020 DN 70 80 100 125 150 46 為了減少管道的能量損失,防止空調(diào)管路表面結(jié)露及保證進(jìn)入空調(diào)設(shè)備和末端空調(diào)機(jī)組的供水溫度,管道及其附件應(yīng)采取保溫措施。 風(fēng)管的保溫設(shè)計(jì) 按防止結(jié)露的保溫層計(jì)算公式為: δ=λ[ ( tltng) /( twgtl) ]/α wg ( ) 其中: δ — 防止結(jié)露的保溫層最小厚度, mm; λ — 保溫材料導(dǎo)熱系數(shù),采用泡沫塑料類可發(fā)祥聚苯乙烯塑料管殼,導(dǎo)熱系數(shù) ~ w/m2 K
點(diǎn)擊復(fù)制文檔內(nèi)容
公司管理相關(guān)推薦
文庫(kù)吧 www.dybbs8.com
備案圖鄂ICP備17016276號(hào)-1