【正文】
1 目 錄 圖紙聯(lián)系 153893706 摘要 ???????????????????????????? Ⅳ ABSTRACT ??????????????????????? Ⅴ 前言 ???????????????????????????? 1 正文 1 工程概況 ??????????????????????? 2 工程概況 ????????????????????? 2 原始資料 ????????????????????? 2 室外氣象參數(shù) ??????????????? 2 建筑結(jié)構(gòu) ????????????????? 2 2 設(shè)計(jì)方案論證 ????????????????????? 3 空調(diào)方案 ???????????????????? 3 水系統(tǒng)布置 ??????????????????? 4 兩管系統(tǒng)的優(yōu)點(diǎn) ?????????????? 4 閉式系統(tǒng)的優(yōu)點(diǎn) ?????????? ???? 4 同程和異程系統(tǒng)的選擇 ??????????? 4 定流量和變流量系統(tǒng) ???????????? 5 風(fēng)系統(tǒng)布置 ?????????????????? 5 3 空調(diào)負(fù)荷計(jì)算 ????????????????????? 6 基本氣象參數(shù) ?????????????????? 6 冷負(fù)荷計(jì)算 ??????????????????? 6 熱負(fù)荷 計(jì)算 ??????????????????? 11 2 4 房間的空氣處理方案及送風(fēng)量的確定 ??????????? 16 房間空氣處理過(guò)程 ???????????????? 16 送風(fēng)量的確定 ?????????????????? 16 5 風(fēng)機(jī)盤(pán)管、新風(fēng)機(jī)組的選擇 ??????????????? 18 風(fēng)機(jī)盤(pán)管的選擇 ????????????????? 18 新風(fēng)機(jī)組的選擇 ????????????????? 20 6 氣流 組織方式的選擇 ?????????????????? 21 概述 ?????????????????????? 21 常用空調(diào)氣流組織方式 ?????????????? 21 房間氣流組織方式 ???????????????? 22 氣流組織計(jì)算和風(fēng)口選擇 ????????????? 22 7 系統(tǒng)水力計(jì)算 ????????????????????? 23 風(fēng)系統(tǒng)水力計(jì)算 ????????????????? 23 通風(fēng)管道的設(shè)計(jì)原則 ??????????? 23 通風(fēng)管道的選擇 ????????????? 23 通風(fēng)管道的制作 ????????????? 23 送風(fēng)管尺寸的確定 ???????????? 23 回、排風(fēng)管尺寸的確定 ?????????? 30 管路平衡 ???????????????? 35 水系統(tǒng)水力計(jì)算 ????????????????? 37 冷凍水系統(tǒng)的選擇 ???????????? 37 冷凍水的水力計(jì)算 ???????????? 37 8 管道保溫 ??????????????????????? 41 3 風(fēng)管的保溫設(shè)計(jì) ???????????????? 41 冷凍水管的保溫設(shè)計(jì) ?????????????? 42 保溫材料的選擇 ???????????? ???? 42 選擇要求 ???????????????? 42 保溫材料 ???????????????? 43 施工過(guò)程中的注意事項(xiàng) ?????????? 43 9 系統(tǒng)消聲 ?????????????????????? 44 噪聲影響及采取的措施 ????????????? 44 消聲裝置的選擇 ???????????????? 44 消聲設(shè)計(jì)步驟 ????????????????? 46 10 系統(tǒng)減振 ??????????????????? ??? 46 11 防排煙系統(tǒng)設(shè)計(jì)及衛(wèi)生間排風(fēng) ????????????? 47 防排煙系統(tǒng)設(shè)計(jì) ???????????????? 47 防排煙方式及其應(yīng)用條件 ????????? 47 加壓送風(fēng)量的確定 ???????????? 48 衛(wèi)生間的排風(fēng)設(shè)計(jì) ??????????????? 49 結(jié)論 ???????????????????????? 50 謝辭 ?????????????? ?????????? 51 參考文獻(xiàn) ?????????????????????? 52 4 摘 要 本次畢業(yè)設(shè)計(jì)的主要內(nèi)容是對(duì)煙臺(tái)市東方賓館進(jìn)行中央空調(diào)系統(tǒng)設(shè)計(jì)及通風(fēng)設(shè)計(jì)。該建筑位于煙臺(tái)市,共十一層 , 建筑總高度 ,總建筑面積 18,000 ㎡。建筑物地下一層包括車庫(kù)、倉(cāng)庫(kù)、制冷機(jī)房、水泵房;一層包括大廳、商場(chǎng)、咖啡廳、餐廳、廚房、商務(wù)中心等;二層為浴室、按摩室、美容美發(fā)、餐廳包間等,層高為 。三層以上是客房、會(huì)議室,層高為 。在技術(shù)設(shè)計(jì)上側(cè)重于中央空調(diào)系統(tǒng)設(shè)計(jì)及地下室的通風(fēng) 設(shè)計(jì)。根據(jù)房間的功能和設(shè)計(jì)要求,風(fēng)系統(tǒng)分別采用了風(fēng)機(jī)盤(pán)管加獨(dú)立的新風(fēng)和全空氣兩種系統(tǒng);水系統(tǒng)采用異程式系統(tǒng)。本次設(shè)計(jì)涉及到空調(diào)系統(tǒng)的劃分,冷熱負(fù)荷的計(jì)算,空調(diào)設(shè)備的選型,風(fēng)管的水力計(jì)算及布置,房間氣流組織計(jì)算,管道的消聲、防震、保溫設(shè)計(jì),冷凍機(jī)房設(shè)計(jì),水系統(tǒng)的劃分,水管的水力計(jì)算及水管布置,水泵和通風(fēng)機(jī)的選擇,通風(fēng)空調(diào)系統(tǒng)的自動(dòng)控制等。 關(guān)鍵詞 : 中央空調(diào);通風(fēng)設(shè)計(jì);設(shè)備選擇;水力計(jì)算;自動(dòng)控制 5 Abstract: The topic of my graduation design is the prehensive ventilation, and central airconditioning system design of Dongfang Hotels. The building is located in Yantai. The earas is about 18,000 square meters and the height is meters. Underground 1 includes garage,storagy,refrigeration room and pump first floor is prised by twostory atrium, offices, restaurants ,kitchen,business center and shopping rooms. There are coffee room, On the 310 level are the rooms and height of the frist floor and the second floor is meters, whears the others height is . The design is focus on the central airconditioning system design and the ventilation of the underground. According to the function room and the design requirements, there are two preject being adopted, the fan disk pulsing new wind and returnd cycle air system. The design project of water system is different programming system. The air conditioning system, the calculation of cold and heat load, the selection of airconditioning, duct hydraulic calculation and the layout, room air distribution, pipelines muffler resistance and thermal design are thought over. The water system division, plumbing and hydraulic calculation of the layout of pipes, pumps and fan choice, ventilation and airconditioning system, and the automatic control were also designed. Keywords: central airconditioning system。 ventilation design。 the selection of airconditioning equipment。 hydraulic calculation。 automatic control 6 前 言 空調(diào)技術(shù)是伴隨著現(xiàn)代文明社會(huì)的進(jìn)步而發(fā)展起來(lái)的。而當(dāng)人們?cè)谙硎苤照{(diào)技術(shù)給人們的生產(chǎn)與生活帶來(lái)方便和舒適時(shí),緊接著也就在思考如何減少空調(diào)所需要銷耗的能量。特別是進(jìn)入 20 世紀(jì) 70 年代以來(lái),以石油危機(jī)為標(biāo)志的世界能源危機(jī)更加促使一些發(fā)達(dá)國(guó)家在各業(yè)中研究和推廣節(jié)能技術(shù)。 改革開(kāi)放以來(lái),隨著我國(guó)國(guó)民經(jīng)濟(jì)的飛速發(fā)展、人民生活水平的逐步提高,人們對(duì)自身生活環(huán)境也越來(lái)越重視,尤其是室內(nèi)的空氣環(huán)境。我國(guó)幅員遼闊,氣候復(fù)雜,室內(nèi)空氣調(diào)節(jié)就顯得非常必要,而且需求量越來(lái)越大。特別是近十年來(lái),空調(diào)技術(shù)在我國(guó)得到空前發(fā) 展,從事空調(diào)行業(yè)的專業(yè)技術(shù)隊(duì)伍日益壯大,同時(shí),大量的空調(diào)設(shè)計(jì)資料也日益完善。 目前,幾乎所有的大型公共建筑都要安裝中央空調(diào)系統(tǒng),對(duì)生產(chǎn)工藝和室內(nèi)潔凈度有特殊要求的地方還必須建立潔凈室。本設(shè)計(jì)便是針對(duì)北京市某酒店賓館的空調(diào)設(shè)計(jì),系統(tǒng)主要由夏季空調(diào)系統(tǒng)、冬季供暖系統(tǒng)兩部分組成。設(shè)計(jì)內(nèi)容在本設(shè)計(jì)說(shuō)明上均有詳細(xì)的說(shuō)明和計(jì)算,圖紙包括空調(diào)系統(tǒng)平面圖、空調(diào)水系統(tǒng)圖、制冷機(jī)房布置圖、空調(diào)機(jī)房布置圖、水系統(tǒng)流程圖、自動(dòng)控制原理圖及主要材料明細(xì)表。 本設(shè)計(jì)中所有計(jì)算及文字說(shuō)明均參考目前通行的相關(guān)規(guī)范、設(shè)計(jì)及施工手冊(cè)。系統(tǒng)方案 由本人單獨(dú)完成,而系統(tǒng)自動(dòng)控制、消聲防震及防排煙等部分,由于本人所學(xué)知識(shí)所限不能對(duì)其進(jìn)行更具體詳細(xì)的設(shè)計(jì),只能依據(jù)設(shè)計(jì)手冊(cè)中的相關(guān)資料,對(duì)其原理進(jìn)行說(shuō)明。 但作為我們畢業(yè)前的一次綜合實(shí)踐,我覺(jué)得本次畢業(yè)設(shè)計(jì)對(duì)我們專業(yè)素質(zhì)提高有非常積極的意義也為我們今后的出色工作打下了堅(jiān)實(shí)的基礎(chǔ)。在這里還需要強(qiáng)調(diào)的是,在設(shè)計(jì)過(guò)程中,承蒙曲云霞老師的耐心指導(dǎo)和大力支持,在此表示衷心感謝! 7 正文 1.工程概況 該工程為煙臺(tái)市東方賓館,建筑共十一層,地下一層,地上十層,建筑總高度 ,總建筑面 積 18000 ㎡。防火設(shè)計(jì)的建筑分為兩類,其耐火等級(jí)為地上一級(jí),地下一級(jí);建筑物地下一層包括車庫(kù)、倉(cāng)庫(kù)、制冷機(jī)房、水泵房;一層包括大廳、商場(chǎng)、咖啡廳、餐廳、廚房、商務(wù)中心等;二層為浴室、按摩室、美容美發(fā)、餐廳包間等三至十層為客房,十一層為屋頂設(shè)備層??照{(diào)系統(tǒng)夏季提供 7(供)12(回)℃冷凍水,冬季提供 60(供) 50(回)℃熱水。水源為自來(lái)水冬季水溫為 10℃ ,夏季為 24℃,由于水源緊張,冷卻水系統(tǒng)必須使用循環(huán)水。 由《空氣調(diào)節(jié)設(shè)計(jì)手冊(cè)》得煙臺(tái)地區(qū)的主要參數(shù)如下: 位 置: 北緯 37176。 32ˊ 東經(jīng) 121176。 24ˊ 大氣壓力: 夏季為 1001kpa 冬季為 1021 kpa 室外溫度: 夏季為 ℃ 冬季為 9℃ 濕球溫度: 夏季為 ℃ 相對(duì)濕度: 冬季為 60% 室外風(fēng)速: 夏季為 建筑結(jié)構(gòu) 圍護(hù)結(jié)構(gòu)的傳熱系數(shù)分別為:外墻 k= w/㎡ .℃ , 內(nèi)墻 k= w/㎡ .℃ ,屋頂 k= w/㎡ .℃ 玻璃 ,k= w/㎡ .℃ . 8 2.設(shè)計(jì)方案論證 空氣調(diào)節(jié)系統(tǒng)的作用是建立和保持建筑物內(nèi)的人工環(huán)境,目的是為了室內(nèi)人員的舒適和健康或?yàn)榱松a(chǎn)過(guò)程的順利進(jìn)行,提高生產(chǎn)效率??照{(diào)過(guò)程中必須采用的基本措施是加熱、加濕、冷卻或去濕。它由冷熱源、空氣處理設(shè)備、