freepeople性欧美熟妇, 色戒完整版无删减158分钟hd, 无码精品国产vα在线观看DVD, 丰满少妇伦精品无码专区在线观看,艾栗栗与纹身男宾馆3p50分钟,国产AV片在线观看,黑人与美女高潮,18岁女RAPPERDISSSUBS,国产手机在机看影片

正文內(nèi)容

自動化外文翻譯---自動化制造系統(tǒng)與plc關(guān)系-plc設(shè)計(存儲版)

2025-06-30 18:40上一頁面

下一頁面
  

【正文】 opularity on the factory floor and will probably remainpredominant for some time to e. Most of this is because of the advantages they offer. Ladder logic Ladder logic is the main programming method used for PLCs. As mentioned before, ladder logic has been developed to mimic relay logic. logic diagrams was a strategic one. By selecting ladder logic as the main programming method, the amount of retraining needed for engineers and tradespeople was greatly reduced. Modern control systems still include relays, but these are rarely used for logic. A relay is a simple device that uses a magic field to control a switch, as pictured in Figure . When a voltage is applied to the input coil, the resulting current creates a magic field. The magic field pulls a metal switch (or reed) towards it and the contacts touch, closing the switch. Figure Simple Relay Layouts and Schematics Relays are used to let one power source close a switch for another (often high current) power source, while keeping them isolated. An example of a relay in a simple control application is shown in Figure . In this system the first relay on the left is used as normally closed, and will allow current to flow until a voltage is applied to the input A. The second relay is normally open and will not allow current to flow until a voltage is applied to the input B. If current is flowing through the first two relays then current will flow through the coil in the third relay, and close the switch for output C. This circuit would normally be drawn in the ladder logic form. This can be read 沈陽建筑大學(xué)畢業(yè)設(shè)計 13 logically as C will be on if A is off and B is on. Figure A Simple Relay Controller The example in Figure does not show the entire control system, but only the logic. When we consider a PLC there are inputs, outputs, and the logic. Figure shows a more plete representation of the PLC. Here there are two inputs from push can imagine the inputs as activating 24V DC relay coils in the PLC. This in turn drives an output relay that switches 115V AC, that will turn on a light. Note, in actual PLCs inputs are never relays, but outputs are often relays. The ladder logic in the PLC is actually a puter program that the user can enter and change. Notice that both of the input push buttons are normally open, but the ladder logic inside the PLC has one normally open contact, and one normally closed contact. Do not think that the ladder logic in the PLC need so match the inputs or outputs. Many beginners will get caught trying to make the ladder logic match the input types . Figure A PLC Illustrated With Relays 沈陽建筑大學(xué)畢業(yè)設(shè)計 14 Many relays also have multiple outputs (throws) and this allows an output relay to also be an input simultaneously. The circuit shown in Figure is an example of this, it is called a seal in circuit. In this circuit the current can flow through either branch of the circuit, through the contacts labelled A or B. The input B will only be on when the output B is on. If B is off, and A is energized, then B will turn on. If B turns on then the input B will turn on, and keep output B on even if input A goes off. After B is turned on the output B will not turn off. Figure A Sealin Circuit Programming The first PLCs were programmed with a technique that was based on relay logic wiring schematics. This eliminated the need to teach the electricians, technicians and engineers how to program a puter but, this method has stuck and it is the most mon technique for programming PLCs today. An example of ladder logic can be seen in Figure . To interpret this diagram imagine that the power is on the vertical line on the left hand side, we call this the hot rail. On the right hand side is the neutral rail. In the figure there are two rungs, and on each rung there are binations of inputs (two vertical lines) and outputs (circles). If the inputs are opened or closed in the right bination the power can flow from the hot rail, through the inputs, to power the outputs, and finally to the neutral rail. An input can e from a sensor, switch, or any other type of sensor. An output will be some device outside the PLC that is switched on or off, such as lights or motors. In the top rung the contacts are normally open and normally closed. Which means if input A is on and input B is off, then power will flow through the output and activate it. Any other bination of input values will result in the output X being off. Figure A Simple Ladder Logic Diagram 沈陽建筑大學(xué)畢業(yè)設(shè)計 15 The second rung of Figure is more plex, there are actually multiple binations of inputs that will result in the output Y turning on. On the left most part of the rung, power could flow through the top if C is off and D is on. Power could also (and simultaneously) flow through the bottom if both E and F are true. This would get power half way across the rung, and then if G or H is true the power will be delivered to output Y. In later chapters we will examine how to interpret and construct these diagrams. There are other methods for programming PLCs. One of the earliest techniques involved mnemonic instructions. These instructions can be derived directly from the ladder logic diagrams and entered into the PLC through a simple programming terminal. An example of mnemonics is shown in Figure . In this example the instructions are read one line at a time from top to bottom. The first line 00000 has the instruction LDN (input load and not) for inpu
點擊復(fù)制文檔內(nèi)容
畢業(yè)設(shè)計相關(guān)推薦
文庫吧 www.dybbs8.com
備案圖鄂ICP備17016276號-1