freepeople性欧美熟妇, 色戒完整版无删减158分钟hd, 无码精品国产vα在线观看DVD, 丰满少妇伦精品无码专区在线观看,艾栗栗与纹身男宾馆3p50分钟,国产AV片在线观看,黑人与美女高潮,18岁女RAPPERDISSSUBS,国产手机在机看影片

正文內(nèi)容

紅安60kv降壓變電所電氣工程初步設(shè)計(jì)畢業(yè)設(shè)計(jì)-wenkub

2022-09-06 21:52:47 本頁(yè)面
 

【正文】 ly, and each calculation etc. knowledge that short circuit order。而根據(jù)本論文所介紹的高壓配電裝置的設(shè)計(jì)原則、要求和 60KV 的配電裝置,決定此次設(shè)計(jì)對(duì)本廠采用分相中型布置。 變壓器的選擇包括:主變壓器 的臺(tái)數(shù)、容量、型號(hào)等主要技術(shù)數(shù)據(jù)的確定;電氣主接線主要介紹了電氣主接線的重要性、設(shè)計(jì)依據(jù)、基本要求、各種接線 形式的優(yōu)缺點(diǎn)以及主接線的比較選擇,并制定了適合本所要求的主接線。 紅安 60KV 降壓變電所電氣工程初步 設(shè)計(jì) 3 ..................................... 錯(cuò)誤 !未定義書(shū)簽。 ..................................... 錯(cuò)誤 !未定義書(shū)簽。 電氣設(shè)備的選擇 ........................................... 錯(cuò)誤 !未定義書(shū)簽。 變電所電氣主接線選擇和短路電流計(jì)算 ....................... 錯(cuò)誤 !未定義書(shū)簽。 電容器的選擇 ............................................. 錯(cuò)誤 !未定義書(shū)簽。 (單 回路) ................................... 錯(cuò)誤 !未定義書(shū)簽。 (雙 回路) ..................................... 錯(cuò)誤 !未定義書(shū)簽。 七、短路電流計(jì)算 ....................................................... 17 (一)短路的定義及類型 ............................................. 17 (二)計(jì)算短路電流的目的 ........................................... 17 (三)短路的原因 ................................................... 17 (四)短路電流的計(jì)算 ............................................... 18 八、電氣設(shè)備選擇 ....................................................... 19 (一)電氣設(shè)備選擇的一般原則 ....................................... 19 (二)斷路器的選擇 ................................................. 19 (三)隔離開(kāi)關(guān)選擇 ................................................. 22 (四)互感器選擇 ................................................... 23 (五)避雷器的選擇 ................................................. 25 (六) 熔斷器的選擇 ................................................. 26 (七)高壓開(kāi)關(guān)柜的選 ............................................... 26 (八)匯流母線的選擇 ............................................... 27 沈陽(yáng)工程學(xué)院畢業(yè)設(shè)計(jì)(論文) 2 九、確定室外設(shè)備布置方式 ............................................... 29 (一)高壓配電裝置和設(shè)計(jì)原則及要求 ................................. 29 (二)設(shè)備的配置 ................................................... 30 (三)配電裝置的選擇 ............................................... 31 十、防雷保護(hù)設(shè)計(jì) ....................................................... 31 (一)變電所直擊雷的過(guò)電壓保護(hù) ..................................... 31 (二)變電所直擊雷保護(hù)的基本原則 ................................... 32 (三)避雷針的設(shè)計(jì) ................................................. 32 第二篇 計(jì)算書(shū) .......................................................... 34 10KV 架空線路選擇 ........................................ 錯(cuò)誤 !未定義書(shū)簽。 廠(雙回路) ..................................... 錯(cuò)誤 !未定義書(shū)簽。 廠(雙回路) ..................................... 錯(cuò)誤 !未定義書(shū)簽。 主變壓器的選擇 ...................................................... 44 總功率 的計(jì)算 ............................................ 44 、無(wú)功功率 .................................... 45 、無(wú)功功率 .................................... 45 容量 的選擇 ................................. 錯(cuò)誤 !未定義書(shū)簽。 功率因數(shù) ......................................... 錯(cuò)誤 !未定義書(shū)簽。 ..................................... 錯(cuò)誤 !未定義書(shū)簽。 ................................... 錯(cuò)誤 !未定義書(shū)簽。 ..................................... 錯(cuò)誤 !未定義書(shū)簽。 ..................................... 錯(cuò)誤 !未定義書(shū)簽。變電所用接線包括:變電所 接線的總要求以及 變電所 母線接線設(shè)計(jì)。繼電保護(hù)和自動(dòng)裝置的規(guī)劃,包括總則、自動(dòng)裝置、一般規(guī)定主 變壓器、母線等設(shè)備的保護(hù), 而 變電所的防雷保護(hù)則主要針對(duì)避雷針和避雷器的設(shè)計(jì)。 The choice of the high pressure electricity equipments includes the mother line, high pressure breaks the road machine and insulate the switch, electric current to feels with each other the machine, electric voltage feels with each other the choice principle of the machine, high pressure switch cabi with request, and proceed to these equipmentseses the school check with the related introduction in product. But go together with the design principle of the electricity device, request to go together with the electricity device with 60 KV according to this thesis a high pressure for introducing, decide this time design to adopt the cent the mutually mediumsized arranging to the my plant. After electricity protection with the programming of the automatic device, include total, automatic device, general provision with the protection of generator, transformer, mother line etc. equipments, but power plant with change to give or get an electric shock a design for defending thunder protecting then primarily aiming at lightning rod with lightning arrester. Key word: Short circuit calculation Examination The choice of the equipments 紅安 60KV 降壓變電所電氣工程初步 設(shè)計(jì) 1 第一篇 說(shuō)明書(shū) 引言 電力系統(tǒng)成為人類歷史發(fā)展的主要?jiǎng)恿Y源,要科學(xué)合理地駕馭電力,必須從電力工程的設(shè)計(jì)原則和方法上來(lái)理解和掌握其精髓,提高電力系統(tǒng)的安全可靠性和運(yùn)行效率,從而達(dá)到降低生產(chǎn)成本,提高經(jīng)濟(jì)效益的目的。 眾所周知,畢業(yè)設(shè)計(jì)是大學(xué)的最后一個(gè)教學(xué)環(huán)節(jié),通過(guò)畢業(yè)設(shè)計(jì)即可以鞏固學(xué)生在學(xué)校學(xué)過(guò)的理論知識(shí),又可以培養(yǎng)學(xué)生運(yùn)用所學(xué)知識(shí)分析和解決工程實(shí)際問(wèn)題的綜合能力,為學(xué)生走出校門后盡快適應(yīng)工作崗位的要求,起到了橋梁和紐帶的作用。 ⑧ 確實(shí)所址時(shí)應(yīng)考慮對(duì)鄰近設(shè)施的影響。 3.所區(qū)內(nèi)、外通道 變電所應(yīng)有道路與外部公路連接 , 其路面寬度一般不小于 米 , 變電所內(nèi)應(yīng)設(shè)置環(huán)行道路或回車道、環(huán)行道 , 路面寬度一般為 3米 , 由變電所大廳至主變電器的道路可適當(dāng)加寬。 電力潮流變化和電壓偏移大的變電所 , 如經(jīng)計(jì)算 , 普通變壓器不能滿足電力系統(tǒng)和用戶對(duì)電壓的要求 , 應(yīng)盡量采用有載調(diào)壓變壓器 , 當(dāng)電力系統(tǒng)運(yùn)行確有需要時(shí) , 可裝設(shè)單獨(dú)的調(diào)壓變壓器 。 ( 3) 35~ 60 千伏 干線配電裝置中當(dāng)出線為 2 回時(shí) , 一般采用橋型接線當(dāng)出線為 2 回以上時(shí) , 一般條件采用分段單母線接線 , 出線回?cái)?shù)較多連接電源較多 , 負(fù)荷大或污穢的環(huán)境中的 35~ 60 千伏屋外配電裝置 , 可采用雙母線接 線 6千伏和 10 千伏配電裝置中 , 可設(shè)置一般采用分段母線和單母線接線。 ○ 1 變壓器分列運(yùn)行。 ( 7)在出線上裝設(shè)電抗器的 6千伏和 10千伏配電裝置中 , 向下同用戶供電的兩回線可共用一臺(tái)斷路器和一組電抗器 , 但每回線上應(yīng)各裝一組出線隔離開(kāi)關(guān)。 常用架空線的型號(hào)、規(guī)格 , 由材料、結(jié)構(gòu)的漢語(yǔ)拼音的第一個(gè)字母在寫(xiě)表示,額定載流截面積( mm2)和鋼線部分額定截面積( mm2)等幾部分組成,字母含義為: T-銅 L-鋁 G-鋼 J-多股絞線 LH-鋁合金 F-防腐型等 。 當(dāng)負(fù)荷電流較大時(shí),應(yīng)根據(jù)負(fù)荷電流選擇較大截面的導(dǎo)線。 (一)導(dǎo)線截面的選擇 導(dǎo)線截面可按長(zhǎng)期發(fā)熱允許電流或經(jīng)濟(jì)電流密度選擇。 年綜合費(fèi)用最低 , 年綜合費(fèi)用包括電流通過(guò)導(dǎo)體產(chǎn) 生的年電能損耗費(fèi) 。再與允許電壓損耗相比較 , 判斷選擇是否適合。只有在 110KV 及以上電壓等級(jí)才需要校驗(yàn)電暈電壓 , 本次設(shè)計(jì)的是 10KV 線路電壓等級(jí)不夠所以不用進(jìn)行電暈電壓校驗(yàn)。通常根據(jù)重要程度將架空線分成三個(gè)等級(jí) : 35KV 以上線路為 I類線路 , 135KV 為Ⅱ類線路 , 1KV以下為Ⅲ類線路。 1. 按導(dǎo)體載流量校驗(yàn) 按導(dǎo)體載流量校驗(yàn)時(shí) , 允許溫度為鋼芯鋁絞線取 +70℃驗(yàn)算時(shí)的周圍空氣溫度采用當(dāng)?shù)厝「吣昶骄鶜鉁?, 架空電力線路的導(dǎo)線截面應(yīng)使導(dǎo)線的最大負(fù)荷電流 。 本設(shè)計(jì)含有單雙回路 , 從最惡劣情況來(lái)看雙回路中,有一條線路開(kāi)路,即僅有一條回路工作 , 所以在線路損耗上全部采用以上公式來(lái)進(jìn)行計(jì)算,如果電壓損失的情況符合條件,那么雙回路一定符合條件。 電力系統(tǒng)各元件中的無(wú)功功率損耗相對(duì)來(lái)說(shuō)較有功功率損耗還要大,由于無(wú)功功率損耗要由發(fā)電機(jī)或其他無(wú)功電源供給,因此在總的發(fā)、送電設(shè)備的視在容量為一定的條件下,無(wú)功功率的增大勢(shì)必相應(yīng)減少發(fā)、送電的有功功率,即發(fā)、送電容量。 SDT85有關(guān)規(guī)定和審批的電力規(guī)劃設(shè)計(jì)決定進(jìn)行。若變電所其他能源可保證在主變停運(yùn)后用戶的一級(jí)負(fù)荷,則可少裝設(shè)一臺(tái)主變壓器。 1. 主變壓器臺(tái)數(shù)、容量的選擇原則 總降壓變電所中,向用戶輸送電能的變壓器稱為主變壓器,根 據(jù)設(shè)計(jì)規(guī)程規(guī)定:變電所中一般裝設(shè)兩臺(tái)
點(diǎn)擊復(fù)制文檔內(nèi)容
環(huán)評(píng)公示相關(guān)推薦
文庫(kù)吧 www.dybbs8.com
備案圖片鄂ICP備17016276號(hào)-1