【正文】
Brocade SAN交換機(jī)常用命令使用電腦連接管理網(wǎng)口,默認(rèn)IP地址為:,掩碼:默認(rèn)用戶名:admin,默認(rèn)密碼password1. switchStatusShow查看交換機(jī)的總體健康狀態(tài)switch:admin switchstatusshowSwitch Health ReportSwitch Name: SWFCRIP address: SwitchState: MARGINALDuration: 863:23Power supplies monitor MARGINALTemperatures monitor HEALTHYFans monitor HEALTHYWWN servers monitor HEALTHYStandby CP monitor HEALTHYBlades monitor HEALTHYFlash monitor HEALTHYMarginal ports monitor HEALTHYFaulty ports monitor HEALTHYMissing SFPs monitor HEALTHYAll ports are healthyswitch:admin2. switchShow查看交換機(jī)基本配置信息Enter the switchShow mand, which displays the following information for a switch: switchname The switch name. switchtype The switch model and firmware version numbers. switchstate The switch state: Online, Offline, Testing, or Faulty. switchrole Displays the switch role: Principal, Subordinate, or Disabled. switchdomain Displays the switch Domain ID. switchid The embedded port D_ID of the switch. switchwwn The switch World Wide Name. switchbeacon The switch beaconing state: either ON or OFF.The switchShow mand also displays the following information for ports on the specifiedswitch: Module type The SFP type if an SFP is present. Port speed The speed of the Port (1G, 2G, 4G, N1, N2, N4, or AN). The speed can befixed, negotiated, or autonegotiated. Port state The port status. Comment About the port. This section may be blank or display the WWN for an F_Port oran E_Port, the trunking state, or upstream or downstream status3. portShow查看端口狀態(tài)switch:admin switch:user portshow 0portName:portHealth: OFFLINEAuthentication: NoneportDisableReason: NoneportCFlags: 0x1portFlags: 0x4001 PRESENT U_PORT LEDportType: portState: 2 OfflineportPhys: 2 No_ModuleportS: 0port generation number: 0portId: 010000portIfId: 43020020portWwn: 20:00:00:60:69:00:02:53portWwn of device(s) connected:Distance: normalportSpeed: N2GbpsLE domain: 0Interrupts: 0 Link_failure: 0 Frjt: 0Unknown: 0 Loss_of_sync: 0 Fbsy: 0Lli: 0 Loss_of_sig: 0Proc_rqrd: 0 Protocol_err: 0Timed_out: 0 Invalid_word: 0Rx_flushed: 0 Invalid_crc: 0Tx_unavail: 0 Delim_err: 0Free_buffer: 0 Address_err: 0Port part of other ADs: Yes4. fanShow查看交換機(jī)散熱風(fēng)扇的狀態(tài)Enter the fanShow mand:switch:admin fanshowFan 1 is OK speed is 7010 RPMFan 2 is OK speed is 7180 RPMFan 3 is OK speed is 7068 RPMFan 4 is OK speed is 7116 RPMFan 5 is OK speed is 7155 RPMFan 6 is OK speed is 7001 RPMswitch:admin5. psShow查看交換機(jī)的電源狀態(tài)注:如果安裝FR418i、FC416IP、FC10FC848板,需要滿配4個電源Enter the psShow mand:switch:admin psshow