freepeople性欧美熟妇, 色戒完整版无删减158分钟hd, 无码精品国产vα在线观看DVD, 丰满少妇伦精品无码专区在线观看,艾栗栗与纹身男宾馆3p50分钟,国产AV片在线观看,黑人与美女高潮,18岁女RAPPERDISSSUBS,国产手机在机看影片

正文內(nèi)容

中文hipulse-local-協(xié)議(客戶版)-文庫吧

2025-07-20 10:42 本頁面


【正文】 plant UPSProgramming the Operator board Communication systemPage 33(03/00)3. “LOCAL” 程序設(shè)置 單一連接PC 機(jī)和一臺功率模塊之間使用一根屏蔽線連接作為串行接口。這根線纜的長度不能超過 15 米( 50 英尺 )。這根長 15 米的線纜是通信組件中的其中之一。Power plant UPS Chapter 4 “LOCAL” PROGRAMCommunication system Run the Program on PCPage 34 (03/00)PARAMETERS POSSIBLE VALUES DEFAULTPage 1Rated Power (kVA) 0010 247。 2022 per USP0010 247。 3000 per MSS9999UPS type Threephase(3P)Singlephase (1P)Not used 3PConfiguration SINGLE for UPSPAR. ISR INT for UPSPAR. ISR EXT for UPSECOMODE for UPSMAINS for MSSSINGLEFor UPSMAINS for MSSRated voltage (V) 380400415400Lower limit VIN (%) 00 247。 99 10Upper limit VIN (%) 00 247。 99 10Lower limit VOUT (%) 00 247。 99 10Upper limit VOUT (%) 00 247。 99 10Nominal (frequency Hz) 506050Tollerance (of Rated Freqency %) 1 247。 9 2Slewrate (Hz/s) Number of celles 150 247。 310 only for UPS 198Rated capacity (Ah) 0000 247。 9999 only for UPS 052End discharge per celles (V) 247。 only for UPS Preal. end discharge per celles (V) 247。 only for UPS Maximum per cells (V) 247。 only for UPS Automatic boost charge NOYESNO of boost charge (min.) 0000 247。 9999 0000Treshold boost charge current (A) 00 247。 99 00Page 2Automatic start NOYESNOTest duration (min.) 00 247。 99 05Alarm threshold voltage (V) 247。 Days to next test (day) 000 247。 999 01Time start test [] 247。 Date start test [] 247。 Motor generator: BLK SYNC NOYESNOMotor generator: BLK CHARGE NOYESNOMotor generator: POWER RED. NOYESNOPage 3Serial number 00000000 247。 99999999 00000000Time of Last Servicing 247。 Date of Last Servicing 247。 Time to Next Servicing 247。 Date to Next Servicing 247。 Programming values of parametersChapter 4 “LOCAL” PROGRAM Power plant UPSRun the Program on PC Communication system Page 35(03/00)CODE ALARM DESCRIPTION UPS MSS BUZZER LED0203040506070809BYPASS SWITCH OPENOUTPUT SWITCH OPENRECTIFIER SWITCH OPENBATTERY . OPENMANUAL BYPASS CLOSEDUsed for visualize EchomodeFAN FAILURENot usedXXXXXXXXXXContinuousContinuousContinuousContinuousPulseContinuousOnOnOnOnInterm.On10111213141516171819Bypass: ABSENTBypass: OVERVOLTAGEBypass: UNDERVOLTAGEBypass: FREQUENCY ERRORBypass: PHASE ROTATION ERR.Bypass: SCR FAILUREBypass: OFFBypass: OFF VIA DISPLAYLOAD ON BYPASSBypass: OVERTEMPERATUREXXXXXXXXXXXXXXXXXXXInterm.Interm.Interm.Interm.ContinuousContinuousPulsePulseInterm.ContinuousInterm.Interm.Interm.Interm.OnOnInterm.Interm.Interm.On20212223242526272829Rectifier: OFFRectifier: OFF VIA DISPLAYRectifier: BLOCKRectifier: CURRENT LIMITRectifier: OVERTEMPERATURERectifier: FUSE FAILURENot usedNot usedNot usedLOAD ON INVERTERXXXXXXXInterm.PulseContinuousInterm.ContinuousContinuousInterm.Interm.OnInterm.OnOn303132333435363738Inverter: OFFInverter: OFF VIA DISPLAYInverter: BLOCKInverter: CURRENT LIMITInverter: OVERTEMPERATUREInverter: UNSYNCHRONIZEDInverter: OVERVOLTAGEInverter: UNDERVOLTAGE Inverter: FUSE FAILUREXXXXXXXXXXXXInterm.Interm.ContinuousContinuousContinuousInterm.ContinuousContinuousContinuousInterm.Interm.OnOnOnInterm.OnOnOn3940414243444546474849Output: OVERVOLTAGEOutput: UNDERVOLTAGEOutput: NO VOLTAGEOutput: WAVEFORM ERROROutput: FREQUENCY ERRORInverter: PARALLEL ERRORCONTACTOR FAILURENR. INVERTERS NOT OKPARALLEL BUS OPENx UPS NOT ACTIVEBATT. CHG. ERRORXXXXXXXXXXXXXXXXContinuousContinuousContinuousContinuousContinuousContinuousContinuousOnOnOnOnOnOnOnOn50515253545556575859Battery: UNDER TESTBattery: TEST FAILEDBattery: ON LOADBattery: END DISCHARGEBOOST TIME EXPIREDDC Bus: SLOW OVERVOLTAGEDC Bus: UNDERVOLTAGEBattery: FUSE FAILUREDC Bus: FAST OVERVOLTAGEBATTERY GROUND FAULTXXXXXXXXXXPulseInterm.Interm.ContinuousPulseContinuousContinuousContinuousContinuousInterm.Interm.Interm.OnInterm.OnOnOnOnIntermPower plant UPS Chapter 4 “LOCAL” PROGRAMCommunication system Run the Program on PCPage 36 (03/00)CODE ALARM DESCRIPTION UPS MSS BUZZER LED606162636465Bypass: TRANSFER COUNT LOCKOVERLOAD SHUTDOWNOVERTEMPERATURE SHUTDOWNEMERGENCY STOPBACKFEED FAULTSYNC. INHIBIT BY TLCXXXXXXXXXContinuousContinuousContinuousContinuousContinuousOnOnOnOnOn66676869OVERLOADOVERLOAD SHUTDOWNNot UsedNot UsedX XXContinuousContinuousOnOn70717273747576Bad EEPROM ProgrammingError LRC parameters page 1Error LRC parameters page 2Error LRC parameters page 3Error LRC Alarm HistoryError LRC Event HistoryInternal battery lowXXXXXXXXXXXXXXPulsePulsePulsePulsePulsePulsePulseOnOnOnOnOnOnOnList of programmable alarms
點(diǎn)擊復(fù)制文檔內(nèi)容
電大資料相關(guān)推薦
文庫吧 www.dybbs8.com
備案圖鄂ICP備17016276號-1