【正文】
material (economic efficiency, environment benefit), request various functions room to use the whole year fortable air conditioning, the design proposal is uses the air blower plate tube one to eleven work halls to add the new atmosphere system. Underground uses the ventilation system.The union construction actual situation, 5 ~ 11 work halls use on deliver under the type ceiling to blow of among, 1 ~4 work halls uses the side blast, saves the space, the repair is artistic. And has carried on the detailed examination to the air current organization. The bathroom uses alone establishes the exhaust system, cold water unit lays aside in the underground engine room。s examination, the Canadian moisture content putation, the equipment shaping, the wind system water power putation and cold water engine room design and the system arrangement.Key Words: The air conditioning; ventilates; a blast row of wind山東XX大學(xué)或畢業(yè)設(shè)計(jì)說明書1前 言空調(diào)通風(fēng)作為一門應(yīng)用性學(xué)科同樣存在著普及與提高兩大任務(wù)。經(jīng)濟(jì)的發(fā)展使從事空調(diào)設(shè)計(jì)人員越來越多,對設(shè)計(jì)要求也越來越高。尤其是近年來能源危機(jī)的出現(xiàn)、環(huán)保意識的不斷提高,對空調(diào)設(shè)計(jì)提出了新的更為嚴(yán)峻的挑戰(zhàn)。滿足方案合理的同時(shí),對空調(diào)設(shè)備進(jìn)行多方面的綜合考慮,選擇最經(jīng)濟(jì)最適宜的型號。由于作者系一名即將畢業(yè)的大學(xué)生,無論是實(shí)踐經(jīng)驗(yàn)還是理論基礎(chǔ)都還比較薄弱。2概 況本工程為徐州市某辦公樓空調(diào)設(shè)計(jì),該樓共6層,建筑總面積約8230平米。地下1層為庫房和設(shè)備用房,地上1層是商場,2~6層為辦公室。外墻采用300毫米厚的加氣混凝土,內(nèi)墻為輕質(zhì)龍骨結(jié)構(gòu),外窗為雙層透明中空玻璃。18′ 室外計(jì)算干球溫度: 冬季室外干球溫度:-8℃ 夏季室外干球溫度:℃ 夏季空調(diào)室外計(jì)算濕球溫度:℃相對濕度: 冬季空調(diào)室外計(jì)算相對濕度:67% 夏季通風(fēng)室外計(jì)算相對濕度:55%風(fēng)速: 冬季風(fēng)速: m / s 夏季風(fēng)速: m / s表21室內(nèi)設(shè)計(jì)參數(shù)房間名稱夏 季冬 季溫度℃相對濕度%溫度℃相對濕度%客房24~2655~7024~2250~30會議室、辦公室25~2755~7023~2040商店24~276523~2040走道、門廳25~276520~1630健身房24601940大堂吧、酒吧26602340宴會廳、餐廳24~266523~2040按摩房26602350休閑娛樂區(qū)256021403. 系 統(tǒng) 方 案 比 較 及 決 定由土建資料得知各房間功能:一層為大廳和辦公大廳。三層到十層為普通辦公空間。地下一層為機(jī)房。在過度季節(jié)能全新風(fēng)運(yùn)行。(即半集中式)風(fēng)機(jī)盤管加新風(fēng)空調(diào)系統(tǒng)具有如下特點(diǎn):優(yōu)點(diǎn):風(fēng)機(jī)盤管加新風(fēng)空調(diào)系統(tǒng)當(dāng)房間熱濕負(fù)荷變化時(shí)能作出相應(yīng)調(diào)節(jié),并且當(dāng)一部分房間不再需要空調(diào)時(shí)可自行調(diào)節(jié),節(jié)約能源。對于一層到六層辦公場所來說,若用風(fēng)機(jī)盤管加新風(fēng)空調(diào)系統(tǒng)可根據(jù)房間的負(fù)荷變化及使用情況進(jìn)行靈活調(diào)節(jié)。綜合以上方案的比較,對該設(shè)計(jì)的空調(diào)系統(tǒng)采用下述方案:對于一至十一層采用全空氣加一次回風(fēng)空調(diào)系統(tǒng)。本設(shè)計(jì)由作者與另一人共同完成,作者負(fù)責(zé)其中五至十一層設(shè)計(jì)部分。則tj‘=(tj+td)KaKb ,外墻冷負(fù)荷計(jì)算公式: ()由于該建筑外表面都為玻璃幕墻,有的房間外墻面積所占外維護(hù)結(jié)構(gòu)面積比例很小,可忽略不計(jì);房間050050050050050050511外墻冷負(fù)荷忽略不計(jì)。— 外玻璃窗的冷負(fù)荷溫度的逐時(shí)值,℃; tn — 地點(diǎn)修正值;透過玻璃窗的日射得熱引起的冷負(fù)荷查《空調(diào)負(fù)荷實(shí)用計(jì)算法》,查表23得窗內(nèi)遮陽設(shè)施的遮陽系數(shù)Cn=(內(nèi)遮陽為活動百葉簾),查表21得夏季日射得熱因數(shù)最大值Djmax :南:251W/㎡ 東:575W/㎡ 北:122W/㎡ 西:575W/㎡查表26得北區(qū)有內(nèi)遮陽窗玻璃冷負(fù)荷系數(shù)CCL值。照明散熱形成的冷負(fù)荷查《空調(diào)負(fù)荷實(shí)用計(jì)算法》表41得照明設(shè)備散熱冷負(fù)荷系數(shù)QCL值。 ()式中 N — 照明燈具所需功率,W; n1—鎮(zhèn)流器消耗功率稀疏,明裝時(shí),n1=,暗裝時(shí),n1=;此為暗裝 n2—燈罩隔熱系數(shù),燈罩有通風(fēng)孔時(shí),n2=—;無通風(fēng)孔時(shí),n2=—;Ccl—照明散熱冷負(fù)荷系數(shù)。散熱設(shè)備冷負(fù)荷計(jì)算公式:,其中N=Fq(F為各房間面積,q為設(shè)備單位發(fā)熱量)。人體散熱與性別,年齡,衣著,勞動強(qiáng)度以及環(huán)境條件(溫、濕度)等多種因素有關(guān)。由于性質(zhì)不同的建筑物中有不同比例的成年男子,女子和兒童數(shù)量,而成年女子和兒童的散熱量低于成年男子。人體顯熱散熱形成的逐時(shí)冷負(fù)荷為: ()式中 qx — 不同室溫和勞動性質(zhì)成年男子顯熱散熱量,W; qq — 不同室溫和勞動性質(zhì)成年男子潛熱散熱量,W;n — 室內(nèi)全部人數(shù);φ — 群集系數(shù);Ccl — 人體顯熱散熱冷負(fù)荷系數(shù);501房間:內(nèi)圍護(hù)結(jié)構(gòu)冷負(fù)荷: ()K=F=(++8)=㎡Δt=5℃Q=*=窗瞬變傳熱冷負(fù)荷: () 501房間窗瞬變傳熱冷負(fù)荷分項(xiàng)時(shí)刻7891011121314151617t262932tj39。tnQcl窗日射得熱冷負(fù)荷: () 501房間窗日射得熱冷負(fù)荷分項(xiàng)時(shí)刻7891011121314151617F=㎡KCZDjmax122W/㎡CclQcl其中根據(jù)不同朝向取不同值南:251 W/㎡;東:575 W/㎡;北:122 W/㎡;西:575 W/㎡;水平:844 W/㎡照明冷負(fù)荷: () 501房間照明冷負(fù)荷分項(xiàng)時(shí)刻012345678910n11n2CclN=Fq=Qcl設(shè)備冷負(fù)荷: () 501房間設(shè)備冷負(fù)荷分項(xiàng)時(shí)刻12345678910CclNQcl人體冷負(fù)荷: () () () 501房間人體冷負(fù)荷分項(xiàng)時(shí)刻12345678910Cclqq57Wqq77WnφQq=Qx319Qcl以上是第501房間的各冷負(fù)荷計(jì)算,其他房間計(jì)算方法與該房間一致,故不另外列出詳細(xì)計(jì)算過程,而以表格的形式列出,具體表格見下表。因此,在計(jì)算熱負(fù)荷是不需要計(jì)算冷風(fēng)滲透耗熱量和冷風(fēng)侵入耗熱量。室內(nèi)人員及燈具所形成的熱負(fù)荷作為安全因素來保證冬季的供暖溫度。查《實(shí)用供熱空調(diào)設(shè)計(jì)手冊》 用內(nèi)差法雙層金屬窗K當(dāng)時(shí)外風(fēng)速小于3m/s時(shí),Kj=K=㎡部分房間包括外墻。人(不小于總風(fēng)量的10%)采用集中式空氣處理機(jī)組,=26℃室內(nèi)沒有燃燒設(shè)備或排氣設(shè)備,故不考慮局部排風(fēng)量.各個(gè)房間面積、人數(shù)及最大冷負(fù)荷匯總見下表: 各房間面積、人數(shù)及最大冷負(fù)荷匯總房間編號面積㎡人數(shù)最大負(fù)荷W5011150295039505750613507135088509951010511125121251377011170297039705770613707137088709971010711127121271371001118025100291003910057100613100713100881009910101010111210121210137110133416711026501房間風(fēng)量計(jì)算根據(jù)衛(wèi)生要求Gw1=20 m3/h—239?!?39。—439?!?39?!?39?!?39?!?39?!?39?!?039?!?139?!?239?!?339?!?439。—1539。—239?!?39。—439?!?39?!?39。—739?!?39?!?39?!?039。—239?!?39?!?39?!?39?!?39。—739?!?39。—939?!?039。—239。制冷機(jī)組及水管附件設(shè)備的選擇(一)冷水機(jī)組的簡介常見的冷水機(jī)組有四種:1:活塞式冷水機(jī)組2:螺桿式冷水機(jī)組3:離心式冷水機(jī)組4:,中小型冷凍站一般選用螺桿式制冷機(jī)組,考慮節(jié)省能源,一般選用吸收式冷水機(jī)組.(二) 冷水機(jī)組的選擇依據(jù):制冷機(jī)組的種類很多,各種機(jī)組的容量范圍和性能都各有特色及最佳的使用條件,應(yīng)根據(jù)用戶的經(jīng)濟(jì)條件,效益及能耗等優(yōu)劣狀況進(jìn)行綜合分析,:1:需要的冷凍水的溫度范圍,供回水溫差,壓力等參數(shù)符合要求。3:節(jié)約能源,保護(hù)環(huán)境。冷凍站的負(fù)荷是制冷設(shè)備選擇的