【正文】 nsformation is said to be a stepdown transformer: conversely, if this voltage is raised, it is called a stepup transformer. In a stepdown transformer the transformation ratio a is greater than unity (a), while for a stepup transformer it is smaller than unity (a). In the event that a=1, the transformer secondary voltage equals the primary voltage. This is a special type of transformer used in instances where electrical isolation is required between the primary and secondary circuit while maintaining the same voltage level. Therefore, this transformer is generally knows as an isolation transformer. As is apparent, it is the magic flux in the core that forms the connecting link between primary and secondary circuit. In section 4 it is shown how the primary winding current adjusts itself to the secondary load current when the transformer supplies a load. Looking into the transformer terminals from the source, an impedance is seen which by definition equals Vp / Ip. From psVV = psII ≌ psEE ≌ a , we have Vp = aVs and Ip = Is/ terms of Vs and Is the ratio of Vp to Ip is ppVI = /ssaVIa = 2ssaVI But Vs / Is is the load impedance ZL thus we can say that Zm (primary) = a2ZL This equation tells us that when an impedance is connected to the secondary side, it appears from the source as an impedance having a magnitude that is a2 times its actual value. We say that the load impedance is reflected or referred to the primary. It is this property of transformers that is used in impedancematching applications. 4. TRANSFORMERS UNDER LOAD The primary and secondary voltages shown have similar polarities, as indicated by the “dotmaking” convention. The dots near the upper ends of the windings have the same meaning as in circuit theory。 it is called the primary leakage flux. The secondary leakage flux gives rise to an induced voltage that is not counter balanced by an equivalent induced voltage in the primary. Similarly, the voltage induced in the primary is not counterbalanced in the secondary winding. Consequently, these two induced voltages behave like voltage drops, generally called leakage reactance voltage drops. Furthermore, each winding has some resistance, which produces a resistive voltage drop. When taken into account, these additional voltage drops would plete the equivalent circuit diagram of a practical transformer. Note that the magizing branch is shown in this circuit, which for our purposes will be disregarded. This follows our earlier assumption that the noload current is assumed negligible in our calculations. This is further justified in that it is rarely necessary to predict transformer performance to such accuracies. Since the voltage drops are all directly proportional to the load current, it means that at noload conditions there will be no voltage drops in either winding. WonCheol Yun , Zhong Xiang Zhang Electric power grid interconnection in Northeast Asia Energy Policy 34 (2022) 2298– 2309
點擊復制文檔內容
畢業(yè)設計相關推薦
文庫吧 www.dybbs8.com
備案圖鄂ICP備17016276號-1