【正文】
sts between the film and the stator leakage phenomenon. 三、電感器、變壓器檢測(cè)方Ⅲ.Inductors, transformers detection methods and experience 1 色碼電感器的的檢1. color code inductor test 將萬(wàn)用表置于 R1 擋,紅、黑表筆各接色碼電感器的任一引出端,此時(shí)指針應(yīng)向右擺動(dòng)。 (2) 初級(jí)繞組與外殼之間的電阻值;(2) the primary winding and the resistance value between the shell。(3) secondary winding and the resistance value between the shell. 上述測(cè)試結(jié)果分出現(xiàn)三(1) 阻值為無(wú)窮大:正常;(4) The resistance is infinity: normal。 (3) 阻值小于無(wú)窮大,但大于零:有漏電性故障。 Such as the coil wire is broken, Sealingoff, insulation materials, whether there are scorch marks, whether the core fastening screw loose, whether silicon steel corrosion, whether there are exposed coil windings, etc.. B 絕緣性測(cè)試。 R 10k block with the multimeter were measured core and primary, primary with the secondary, with the subcore, electrostatic shielding layer and panties secondary, secondary resistance between the windings, multimeter pointer refers to the infinity position should not action. 否則,說(shuō)明變壓器絕緣性能不良。coiloff detection. 將萬(wàn)用表置于 R1 擋,測(cè)試中,若某個(gè)繞組的電阻值為無(wú)窮大,則說(shuō)明此繞組有斷路性故障。determine the beginning of secondary coil. 電源變壓器初級(jí)引腳和次級(jí)引腳一般都是分別從兩側(cè)引出的,并且初級(jí)繞組多標(biāo)有 220V 字樣,次級(jí)繞組則標(biāo)出額定電壓值,如 15V 、 24V 、 35V 等。Then according to these tags to identify. E 空載電流的檢測(cè)。direct measurement method. 將次級(jí)所有繞組全部開(kāi)路,把萬(wàn)用表置于交流電流擋 (500mA ,串入初級(jí)繞組。此值不應(yīng)大于變壓器滿(mǎn)載電流的 10 %~ 20 %。如果超出太多,則說(shuō)明變壓器有短路性故障。在變壓器的初級(jí)繞組中串聯(lián)一個(gè) 10 /5W 的電阻,次級(jí)仍全部空載。加電后,用兩表筆測(cè)出電阻 R 兩端的電壓降 U ,然后用歐姆定律算出空載電流 I 空,即 I 空 =U/R 。將電源變壓器的初級(jí)接 220V 市電,用萬(wàn)用表交流電壓接依次測(cè)出各繞組的空載電壓值 (U21 、 U22 、 U23 、 U24) 應(yīng)符合要求值,允許誤差范圍一般為:高壓繞組≤177。 5 %,帶中心抽頭的兩組對(duì)稱(chēng)繞組的電壓差應(yīng)≤177。 G 一般小功率電源變壓器允許溫升為 40 ℃~ 50 ℃,如果所用絕緣材料質(zhì)量較好,允許溫升還可提高。在使用電源變壓器時(shí),有時(shí)為了得到所需的次級(jí)電壓,可將兩個(gè)或多個(gè)次級(jí)繞組串聯(lián)起來(lái)使用。否則,變壓器不能正常工作。電源變壓器發(fā)生短路性故障后的主要癥狀是發(fā)熱嚴(yán)重和次級(jí)繞組輸出電壓失常。檢測(cè)判斷電源變壓器是否有短路性故障的簡(jiǎn)單方法是測(cè)量空載電流 ( 測(cè)試方法前面已經(jīng)介紹 ) 。當(dāng)短路嚴(yán)重時(shí),變壓器在空載加電后幾十秒鐘之內(nèi)便會(huì)迅速發(fā)熱,用手觸摸鐵心會(huì)有燙手的感覺(jué)。 All the secondary winding of all the open, the AC current meter placed in block (500mA, string into the primary winding. When the primary winding of the plug into 220V AC electricity, the meter is indicated by noload current value. This value should not be transformer full load current is greater than 10% ~ 20%. the general mon electronic devices power transformer should be the normal load current of about 100mA. If you exceed too much, then power transformer shortcircuit failures. indirect measurement. In the transformer primary winding in series a 10 / 5W resistor, the sub is still all empty. the multimeter to AC voltage block allocation. added power, you use two tables resistance R T measured voltage drop across the U, and then use Ohm39。 10%, lowvoltage winding ≤ 177。 2%. G general low power power transformer to allow temperature rise 40 ℃ ~ 50 ℃, if the use of good quality insulation materials, allowing temperature can be increased. H test discriminant end of each winding of the same name. in the use of power transformers, sometimes in order to get the required secondary voltage can be two or more secondary windings together in series to use. using tandem Law uses the power transformer, the participants in series of the same name each winding terminal must be properly connected, can not be wrong. Otherwise, the transformer can not be normal work. I. power transformer shortcircuit Fault prehensive test discriminant. power transformer shortcircuit fault occurs after the main symptoms are fever and secondary winding output voltage of serious disorders. Typically, the coil inside the more interturn short circuit, shortcircuit current of more large, while the more serious heat transformer. testing to determine whether there is power transformer shortcircuit fault of the simple way is to measure the load current (test methods have been introduced earlier). there is a transformer shortcircuit fault, its noload current value will be greater than full load current of 10%. When a serious short circuit, the transformer in load after powerup will be rapid, within tens of seconds, fever, handtocore will have a hot feeling. At this point can be determined withoutmeasuring noload current transformer shortcircuit spots.中文元器件的檢測(cè)是家電維修的一項(xiàng)基本功,如何準(zhǔn)確有效地檢測(cè)元器件的相關(guān)參數(shù),判斷元器件的是否正常,不是一件千篇一律的事,必須根據(jù)不同的元器件采用不同的方法,從而判斷元器件的正常與否。一、電阻器的檢測(cè)方法與經(jīng)驗(yàn):固定電阻器的檢測(cè)。為了提高測(cè)量精度,應(yīng)根據(jù)被測(cè)電阻標(biāo)稱(chēng)值的大小來(lái)選擇量程。根據(jù)電阻誤差等級(jí)不同。5%、177。20%的誤差。注意:測(cè)試時(shí),特別是在測(cè)幾十kΩ以上阻值的電阻時(shí),手不要觸及表筆和電阻的導(dǎo)電部分;被檢測(cè)的電阻從電路中焊下來(lái),至少要焊開(kāi)一個(gè)頭,以免電路中的其他元件對(duì)測(cè)試產(chǎn)生影響,造成測(cè)量誤差;色環(huán)電阻的阻值雖然能以色環(huán)標(biāo)志來(lái)確定,但在使用時(shí)最好還是用萬(wàn)用表測(cè)試一下其實(shí)際阻值。檢測(cè)水泥電阻的方法及注意事項(xiàng)與檢測(cè)普通固定電阻完全相同。在電路中,當(dāng)熔斷電阻器熔斷開(kāi)路后,可根據(jù)經(jīng)驗(yàn)作出判斷:若發(fā)現(xiàn)熔斷電阻器表面發(fā)黑或燒焦,可斷定是其負(fù)荷過(guò)重,通過(guò)它的電流超過(guò)額定值很多倍所致;如果其表面無(wú)任何痕跡而開(kāi)路,則表明流過(guò)的電流剛好等于或稍大于其額定熔斷值。若測(cè)得的阻值為無(wú)窮大,則說(shuō)明此熔斷電阻器已失效開(kāi)路,若測(cè)得的阻值與標(biāo)稱(chēng)值相差甚遠(yuǎn),表明電阻變值,也不宜再使用。電位器的檢測(cè)。用萬(wàn)用表測(cè)試時(shí),先根據(jù)被測(cè)電位器阻值的大小,選擇好萬(wàn)用表的合適電阻擋位,然后可按下述方法進(jìn)行檢測(cè)。檢測(cè)電位器的活動(dòng)臂與電阻片的接觸是否良好。再順時(shí)針慢慢旋轉(zhuǎn)軸柄,電阻值應(yīng)逐漸增大,表頭中的指針應(yīng)平穩(wěn)移動(dòng)。如萬(wàn)用表的指針在電位器的軸柄轉(zhuǎn)動(dòng)過(guò)程中有跳動(dòng)現(xiàn)象,說(shuō)明活動(dòng)觸點(diǎn)有接觸不良的故障。檢測(cè)時(shí),用萬(wàn)用表R1擋,具體可分兩步操作:常溫檢測(cè)(室內(nèi)溫度接近25℃);將兩表筆接觸PTC熱敏電阻的兩引腳測(cè)出其實(shí)際阻值,并與標(biāo)稱(chēng)阻值相對(duì)比,二者相差在177。實(shí)際阻值若與標(biāo)稱(chēng)阻值相差過(guò)大,則說(shuō)明其性能不良或已損壞。注意不要使熱源與PTC熱敏電阻靠得過(guò)近或直接接觸熱敏電阻,以防止將其燙壞。(1)、測(cè)量標(biāo)稱(chēng)電阻值Rt用萬(wàn)用表測(cè)量NTC熱敏電阻的方法與測(cè)量普通固定電阻的方法相同,即根據(jù)NTC熱敏電阻的標(biāo)稱(chēng)阻值選擇合適的電阻擋可直接測(cè)出Rt的實(shí)際值。測(cè)量功率不得超過(guò)規(guī)定值,以免電流熱效應(yīng)引起測(cè)量誤差。測(cè)試時(shí),不要用手捏住熱敏電阻體,以防止人體溫度對(duì)測(cè)試產(chǎn)生影響。壓敏電阻的檢測(cè)。若所測(cè)電阻很小,說(shuō)明壓敏電阻已損壞,不能使用。用一黑紙片將光敏電阻的透光窗口遮住,此時(shí)萬(wàn)用表的指針基本保持不動(dòng),阻值接近無(wú)窮大。若此值很小或接近為零,說(shuō)明光敏電阻已燒穿損壞,不能再繼續(xù)使用。此值越小說(shuō)明光敏電阻性能越好。C將光敏電阻透光窗口對(duì)準(zhǔn)入射光線(xiàn),用小黑紙片在光敏電阻的遮光窗上部晃動(dòng),使其間斷受光,此時(shí)萬(wàn)用表指針應(yīng)隨黑紙片的晃動(dòng)而左右擺動(dòng)。二、電容器的檢測(cè)方法與經(jīng)驗(yàn)固定電容器的檢測(cè),用萬(wàn)用表進(jìn)行測(cè)量,只能定性的檢查其是否有漏電,內(nèi)部短路或擊穿現(xiàn)象。若測(cè)出阻值(指針向右擺動(dòng))為零,則說(shuō)明電容漏電損壞或內(nèi)部擊穿。萬(wàn)用表選用R1k擋??蛇x用3DG6等型號(hào)硅三極管組成復(fù)合管。由于復(fù)合三極管的放大作用,把被測(cè)電容的充放電過(guò)程予以放大,使萬(wàn)用表指針擺幅度加大,從而便于觀(guān)察。對(duì)于0~01μF以上的固定電容,可用萬(wàn)用表的R10k擋直接測(cè)試電容器有無(wú)充電過(guò)程以及有無(wú)內(nèi)部短路或漏電,并可根據(jù)指針向右擺動(dòng)的幅度大小估計(jì)出電容器的容量。根據(jù)經(jīng)驗(yàn),一般情況下,1~47μF間的電容,可用R1k擋測(cè)量,大于47μF的電容可用R100擋測(cè)量。此時(shí)的阻值便是電解電容的正向漏電阻,此值略大于反向漏電阻。在測(cè)試中,若正向、反向均無(wú)充電的現(xiàn)象,即表針不動(dòng),則說(shuō)明容量消失或內(nèi)部斷路;如果所測(cè)阻值很小或?yàn)榱悖f(shuō)明電容漏電大或已擊穿損壞,不能再使用。即先任意測(cè)一下漏電阻,記住其大小,然后交換表筆再測(cè)出一個(gè)阻值。使用萬(wàn)用表電阻擋,采用給電解電容進(jìn)行正、反向充電的方法,根據(jù)指針向右擺動(dòng)幅度的大小,可估測(cè)出電解電容的容量。將載軸向前、后、上、下、左、右等各個(gè)方向推動(dòng)時(shí),轉(zhuǎn)軸不應(yīng)有松動(dòng)的現(xiàn)象。轉(zhuǎn)軸與動(dòng)片之間接觸不良的可變電容器,是不能再繼續(xù)使用的。在旋動(dòng)轉(zhuǎn)軸的過(guò)程中,如果指針有時(shí)指向零,說(shuō)明動(dòng)片和定片之間存在短路點(diǎn);如果碰到某一角度,萬(wàn)用表讀數(shù)不為無(wú)窮大而是出現(xiàn)一定阻值,說(shuō)明可變電容器動(dòng)片與定片之間存在漏電現(xiàn)象。根據(jù)測(cè)出的電阻值大小,可具體分下述三種情況進(jìn)行鑒別:被測(cè)色碼電感器電阻值為零,其內(nèi)部有短路性故障。 中周變壓器的檢測(cè)將萬(wàn)用表?yè)苤罵1擋,按照中周變壓器的各繞組引腳排列規(guī)律,逐一檢查各繞組的通斷情況,進(jìn)而判斷其是否正常。上述測(cè)試結(jié)果分出現(xiàn)三種情況:(1)阻值為無(wú)窮大:正常;(2)阻值為零:有短路性故障; (3)阻值小于無(wú)窮大,但大于零: