畢業(yè)論文-35kv變電所電氣部分設(shè)計(jì)-在線瀏覽

2025-03-05 19:45本頁(yè)面
  

【正文】 ............. 33 10kV 高壓開關(guān)柜 .......................................................................................................... 34 8 繼電保護(hù)的設(shè)置 ............................................................................................................................... 35 電力變壓器保護(hù) ...................................................................................................................... 35 35kV 變電所電氣部分設(shè)計(jì) 第 3 頁(yè) 共 50 頁(yè) 電力變壓器保護(hù)概述 ................................................................................................... 35 電力變壓器縱差保護(hù)接線 ........................................................................................... 35 縱差動(dòng)保護(hù)的整定計(jì)算 ............................................................................................... 36 變壓器瓦斯保護(hù) ........................................................................................................... 37 過電流保護(hù) ................................................................................................................... 37 母線保護(hù) .................................................................................................................................. 38 9 變電所的防雷保護(hù) ........................................................................................................................... 38 變電所防雷概述 ...................................................................................................................... 38 避雷針的選擇 .......................................................................................................................... 39 避雷器的選擇 .......................................................................................................................... 40 結(jié)論 ........................................................................................................................................................ 41 致謝 ........................................................................................................................................................ 42 參考文獻(xiàn) ................................................................................................................................................. 43 35kV 變電所電氣部分設(shè)計(jì) 第 1 頁(yè) 共 50 頁(yè) 摘要 : 隨 著 電力行業(yè)的不斷發(fā)展,人們對(duì)電力供應(yīng)的要求越來越高,特別是供 穩(wěn)固 性、可靠性和持續(xù)性。然而電網(wǎng)的穩(wěn)固性、可靠性和持續(xù)性往往取決于變電所的合理設(shè)計(jì)和配置。出于這幾方面的考慮,本論文設(shè)計(jì)了一個(gè) 35kV 降壓變電站 ,此變電站有兩個(gè)電壓等級(jí),一個(gè)是 35kV,一個(gè)是 10kV。本設(shè)計(jì)選擇選擇兩臺(tái)主變壓器,其他設(shè)備如斷路器,隔離開關(guān),電流互感器,電壓互感器,無功補(bǔ)償裝置和繼電保護(hù)裝置等等也按照具體要求進(jìn)行選型、 設(shè)計(jì)和配置,力求做到運(yùn)行可靠,操作簡(jiǎn)單、方便,經(jīng)濟(jì)合理,具有擴(kuò)建的可能性和改變運(yùn)行方式時(shí)的靈活性。 關(guān)鍵詞 35kV 變電所 設(shè)計(jì) 35kV 變電所電氣部分設(shè)計(jì) 第 2 頁(yè) 共 50 頁(yè) Abstract: Along with the continuous development of electric industry, people require increasingly demand of power supply, especially the stability, reliability and continuity of it. While the stability, reliability and continuity of power grid is determined by the rational design and configuration of substation. A typical substation needs the reliable and flexible operation, the economic rationality and free expansion of the equipments. For the consideration of these aspects, the paper designs a transformer substation of 35kV which has tow level of voltage, one is 35kV, and the other is 10kV. At the same time, choose the rational selection as to the main equipments in substation. This design chooses two main transformers. As to other equipments such as Circuit Breaker, Isolating switch, Current Transformer, Voltage Transformer, Reactive power pensation device, Protective Relay and so on are to be selected, designed, and configured in accordance with specific requirements. In order to make it reliable to operate, easy and simple to manipulate, economical, with the possibility of expansion and flexibility of changing its operation. As to make it more actual and practical significant. Key words 35kV substation design 35kV 變電所電氣部分設(shè)計(jì) 第 3 頁(yè) 共 50 頁(yè) 1 引 言 電能是發(fā)展國(guó)民經(jīng)濟(jì)的基礎(chǔ),是一種無形的、不能大量?jī)?chǔ)存的二次能源。要滿足國(guó)民經(jīng)濟(jì)發(fā)展的要求,電力工業(yè)必須超前發(fā)展,這是世界電力工業(yè)發(fā)展規(guī)律,因此,做好電力規(guī)劃,加強(qiáng)電網(wǎng)建設(shè),就尤為重要。對(duì)其進(jìn)行設(shè)計(jì)勢(shì)在必行,合理的變電所不僅能充分地滿足當(dāng)?shù)氐墓╇娦枨?,還能有效地減少投資和資源浪費(fèi)。并依據(jù)相關(guān)規(guī)定和章程設(shè)計(jì)其中個(gè)個(gè)步驟,所以能滿足一般變電所的需求。為此 新的設(shè)備選擇也在設(shè)計(jì)中得以體現(xiàn)。 35kV 變電所電氣部分設(shè)計(jì) 第 4 頁(yè) 共 50 頁(yè) 2 原始資料 電力系統(tǒng)接線圖 待設(shè)計(jì)變電所進(jìn)線如圖 1 所示: 圖 變電所進(jìn)線示意圖 系統(tǒng)情況 待設(shè)計(jì)變電所通過一條架空線路由正西方向 5km處的一座 110kV變電所 A送電,回路最大傳輸功率不大于 , A變電所系統(tǒng)容量為 3000MW。本所投運(yùn)后功率因數(shù)要求到達(dá) 。 本地區(qū)氣象條件 最高氣溫 C??? 41max? ;最低氣溫 C??? 12min? ;年平均氣溫 Cavy ??? ? ;最熱月平均最高溫度 Cavm ??? 26? 。如重要大型設(shè)備損失、重要產(chǎn)品或重要原料生產(chǎn)的產(chǎn)品大量報(bào)廢、連續(xù)生產(chǎn)過程被打亂且需要長(zhǎng)時(shí)間才能恢復(fù)、造成社會(huì)秩序嚴(yán)重混亂或產(chǎn)生政治上的重大影響、重要的交通和通訊樞紐中斷、國(guó)際社交場(chǎng)所沒有照明等。如生產(chǎn)的主要設(shè)備損壞、產(chǎn)品大量報(bào)廢或減 產(chǎn)、連續(xù)生產(chǎn)過程需要較長(zhǎng)時(shí)間才能恢復(fù)、造成社會(huì)秩序混亂、在政治上產(chǎn)生較大影響、交通和通訊樞紐以及城市供水中斷、廣播電視、商貿(mào)中心被迫停止運(yùn)營(yíng)等。對(duì)于這類負(fù)荷,供電所所造成的損失不大或不會(huì)直接造成損失。對(duì)于一級(jí)負(fù)荷的用電設(shè)備,應(yīng)有兩個(gè)及以上的獨(dú)立電源供電,并輔之一其他必要的非電保安設(shè)施。三級(jí)負(fù)荷對(duì)供電無特殊要求,允許較長(zhǎng)時(shí)間停電,可用單回線路供電。 負(fù)荷計(jì)算 10kV側(cè)的負(fù)荷計(jì)算 ??P +++1++= ??Q *+*+*+1*+*+*= ??S ? ?? 22 )()( QP ( 31) = 22 ? = 功率因數(shù) cos? = 無功補(bǔ)償 無功補(bǔ)償概述 電力系統(tǒng)中有許多根據(jù)電磁感應(yīng)原理工作的電氣設(shè)備,如變壓器、電動(dòng)機(jī)、感應(yīng)爐等。電力系統(tǒng)中的無功功率很大,必須有足夠的無功電源,才能維持一定的電壓水平,滿足系統(tǒng)安全穩(wěn)定運(yùn)行的要求。 2 無功功率補(bǔ)償裝置(并聯(lián)電容器和同步調(diào)相機(jī))輸出無功功率。 電力系統(tǒng)中如無功功率小,將引起供電電網(wǎng)的電壓降低。電壓下降到額定電壓值的 60%~70%時(shí),用戶的電動(dòng)機(jī)將不能啟動(dòng)甚至造成燒毀。 無功補(bǔ)償?shù)挠?jì)算 補(bǔ)償前 cos 1? =,求補(bǔ)償后達(dá)到 。39。并聯(lián)補(bǔ)償裝置又可分為同期調(diào)相機(jī)、并聯(lián)電容補(bǔ)償裝置、靜補(bǔ)裝置等幾大類。在我國(guó)經(jīng)常在樞紐變電所安裝同步調(diào)相機(jī),以便平滑調(diào)節(jié)電壓和提高系統(tǒng)穩(wěn)定性。 電容器可發(fā)出無功功率,電抗器可吸收無功功率,根據(jù)電壓需要,向電網(wǎng)提供快速無級(jí)連續(xù)調(diào)節(jié)的容性和感性的無功,降低電壓波動(dòng)和波形畸變率,全面提高電壓質(zhì)量,并兼有減少有功損耗,提高系統(tǒng)穩(wěn)定性,降低工頻過電壓的功能。但設(shè)備造價(jià)太高,本設(shè)計(jì)中不宜采用。既可集中安裝,又可35kV 變電所電氣部分設(shè)計(jì) 第 8 頁(yè) 共 50 頁(yè) 分散裝設(shè)來接地供應(yīng)無功功率,運(yùn)行時(shí)功率損耗亦較小。 并聯(lián)電容器裝置的分組 1 分組原則 ( 1)對(duì)于單獨(dú)補(bǔ)償?shù)哪撑_(tái)設(shè)備,例如電動(dòng)機(jī)、小容量變壓器等用的并聯(lián)電容器裝置,不必分組,可直接與該設(shè)備相連接,并與該設(shè)備同時(shí)投切。此時(shí),為保證一定的功率因數(shù),各組應(yīng)能隨負(fù)荷的變化實(shí)行自動(dòng)投切。 ( 3)終端變電所的并聯(lián)電容器裝置,主要是為了提高電壓和補(bǔ)償主變壓器的無功損耗。投切任一組電容器時(shí)引起的電壓波動(dòng)不應(yīng)超過 %。這幾種方式中等容量分組方式,分組斷路器不僅要滿足頻繁切合并聯(lián)電容器的要求,而且還要滿足開斷短路的要求,這種分組方式應(yīng)用較多,因此采用等容量分組方式。經(jīng)常采用的還有由星形派生出的雙星形,在某種場(chǎng)合下,也有采用由三角形派生出的雙三角形。 并聯(lián)電容器組裝設(shè)在變電所低壓側(cè),主要是補(bǔ)償主變和負(fù)荷的
點(diǎn)擊復(fù)制文檔內(nèi)容
規(guī)章制度相關(guān)推薦
文庫(kù)吧 www.dybbs8.com
備案圖鄂ICP備17016276號(hào)-1