【正文】
筑給水工程設(shè)計(jì)的主要內(nèi)容有:用水量計(jì)算,給水方式的確定,管道設(shè)備的布置,管道的水力計(jì)算及室內(nèi)所需水壓的計(jì)算,水池、水箱的容積確定和構(gòu)造尺寸確定,水泵的流量、揚(yáng)程及型號(hào)的確定,管道設(shè)備的材料及型號(hào)的選用,施工圖的繪制和施工要求。排水塑料管的噪聲防治問(wèn)題上,或采用改變水流狀態(tài)的方法、或采用改變管道結(jié)構(gòu)型式、或兼用兩種方式,都有一定效果。另外,為保障高層建筑火災(zāi)初期消防水壓及水量而設(shè)計(jì)的穩(wěn)高壓系統(tǒng),先從上海地區(qū)得到應(yīng)用,然后逐步在各地推廣開(kāi)來(lái),其計(jì)算及設(shè)計(jì)手段逐漸成熟,乃至有人建議將穩(wěn)高壓消防給水系統(tǒng)單獨(dú)列入《高層民用建筑設(shè)計(jì)防火規(guī)范》以區(qū)別原有的常高壓消防給水系統(tǒng)和臨時(shí)高壓消防給水系統(tǒng)。這些調(diào)整都是注入了廣大設(shè)計(jì)人員近年來(lái)工作研究實(shí)踐得出的寶貴經(jīng)驗(yàn),以及借簽了國(guó)外工程設(shè)計(jì)經(jīng)驗(yàn)的結(jié)果。 首先,因?yàn)楦邔咏ㄖ南捞攸c(diǎn)是“立足于自救”,因而自動(dòng)噴水滅火系統(tǒng)的設(shè)計(jì)更加受到重視,新的《自動(dòng)噴水滅火系統(tǒng)設(shè)計(jì)規(guī)范》己于2006年頒布執(zhí)行。其次,變頻恒壓調(diào)速供水技術(shù)日益成熟,加上減壓閥的使用,改善了原來(lái)高層建筑“水箱水泵聯(lián)合供水”、“水箱減壓”方法中出現(xiàn)的“水質(zhì)二次污染”和“水箱占用大量建筑面積”的狀況,同時(shí)也達(dá)到了節(jié)能效果,而且在現(xiàn)在的設(shè)計(jì)中優(yōu)先采用變頻泵供水。經(jīng)驗(yàn)法,概率法,平方根法等計(jì)算方法不斷地被修正和改進(jìn)。近年來(lái),隨著高層建筑業(yè)的快速發(fā)展,建筑給水排水工程設(shè)計(jì)方法也有了不少的改進(jìn)和更新。高層建筑對(duì)防噪聲、防震等要求較高,但室內(nèi)管道及設(shè)備種類(lèi)繁多、管線長(zhǎng)、噪聲源和震源多,必須考慮管道的防震、防沉降、防噪聲、防腐蝕、防水錘、防管道伸縮變位、防壓力過(guò)高等措施。高層建筑的功能復(fù)雜,失火可能性大,失火后蔓延迅速,人員疏散及撲救困難。下面就高層建筑給水排水工程的主要特點(diǎn)介紹如下:高層建筑層數(shù)多、高度大。總之,高層建筑給排水工程的中心任務(wù)是為建筑提供方便、衛(wèi)生、舒適和安全的生產(chǎn)、生活環(huán)境。此外還有建筑配套設(shè)施給水排水工程,其任務(wù)主要是汽車(chē)庫(kù)、人防的給排水。建筑給水工程的任務(wù),主要是解決建筑內(nèi)部的生活、生產(chǎn)、消防用水問(wèn)題,以滿足日常生活、生產(chǎn)、保障人身和財(cái)產(chǎn)的安全的需求。當(dāng)前,發(fā)達(dá)國(guó)家的城市居民用量更大,每人每天約需400500L水,最高的超過(guò)800L。在日常生活中,每人每天大約需要2L水才能維持正常的生存。建筑給排水工程在水工業(yè)中有著其自身特有的地位,它是水工業(yè)總循環(huán)線路的中間環(huán)節(jié),對(duì)水工業(yè)總循環(huán)起著控制作用。組織上成立了全國(guó)建筑給排水工程標(biāo)準(zhǔn)技術(shù)委員會(huì)和中國(guó)土木學(xué)會(huì)給排水學(xué)會(huì)建筑給水排水委員會(huì)。在發(fā)展階段,專(zhuān)業(yè)隊(duì)伍上已具備積累了一定經(jīng)驗(yàn)并經(jīng)過(guò)專(zhuān)業(yè)培訓(xùn)的設(shè)計(jì)、施工、安裝管理人員。 3.建筑給排水階段即發(fā)展階段,自1986年至今。2.室內(nèi)給排水階段即反思階段,自1964年至1986年《建筑給水排水設(shè)計(jì)規(guī)范》被審批通過(guò)時(shí)為止。其主要標(biāo)志是我國(guó)開(kāi)始設(shè)置給水排水專(zhuān)業(yè),房屋衛(wèi)生技術(shù)設(shè)備被確定為一門(mén)獨(dú)立的專(zhuān)業(yè)課程。 Water pipe material一.文獻(xiàn)綜述任何一門(mén)學(xué)科要想對(duì)其深入了解就得從其歷史發(fā)展開(kāi)始。 The building stormwater system adopts inner draining. The water pipe and drain pipes respectively adopt the PP R tube and the UPVC tubes , the fire fight system and the hot water systemses all adopt to plate the zinc steel pipe. In the designation process ,I carried on settling each system project , the flat surface arranges and puting, and choseing the type of various equipments , and do the great engineering budget estimation and establishment procedure of the Excel. finally,Drew the flat surface construction diagram and the system stalk side diagrams of each system with the CAD.Key Words:: high building。最后用CAD繪制了各個(gè)系統(tǒng)的平面施工圖和系統(tǒng)軸側(cè)圖。給水管和排水管分別采用PP—R管和UPVC管,消防系統(tǒng),噴淋系統(tǒng)都采用鍍鋅鋼管。消防系統(tǒng)設(shè)計(jì)成消火栓滅火系統(tǒng)和自動(dòng)噴淋系統(tǒng)同時(shí)使用,火災(zāi)初期10min的水由消防水箱供給,火災(zāi)延續(xù)時(shí)由消防水泵從貯水池內(nèi)抽取(提供兩小時(shí)滅火用水量)。六層到十一層為中區(qū),十二層到十七層(十八層為屋頂花園)為高區(qū),均采用無(wú)負(fù)壓變頻供水。設(shè)計(jì)內(nèi)容包括給水系統(tǒng)、排水系統(tǒng)、消火栓系統(tǒng)、自動(dòng)噴淋系統(tǒng)和雨水系統(tǒng)五個(gè)部分。十八層辦公大樓畢業(yè)設(shè)計(jì)目錄摘 要 3ABSTRACT 5一.文獻(xiàn)綜述 3 3 3 3 3 3 3 3 3二.設(shè)計(jì)任務(wù)書(shū) 3 3 3 3 3 3三.設(shè)計(jì)說(shuō)明書(shū) 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 清掃口和檢查井的設(shè)置要求 3 3 3 3 3 3 3 3 3 系統(tǒng)選擇 3 噴頭選擇和布置 3 管網(wǎng)布置 3 33. 3 3 管道的布置與敷設(shè) 3四.設(shè)計(jì)計(jì)算書(shū) 3 3 3 3 3 3 3 3 3 3 3 室內(nèi)排水橫管計(jì)算注意事項(xiàng) 3: 3 3 3 室內(nèi)消火栓給水系統(tǒng) 3 設(shè)計(jì)說(shuō)明 3 消火栓布置 3 水槍噴嘴處所需水壓 3 管道布置 3 水帶阻力 3 消火栓口所需壓力 3 水力計(jì)算 3 消防水箱 3 消防貯水池 3 自動(dòng)噴水滅火系統(tǒng)設(shè)計(jì)與計(jì)算 3 3 3 3 3 3 3 錯(cuò)誤!未定義書(shū)簽。 3 3 雨量計(jì)算 3 3.雨水流量計(jì)算 3 3五.結(jié)束語(yǔ) 3六.致謝 3參考文獻(xiàn) 3摘 要本設(shè)計(jì)是武漢市陽(yáng)邏創(chuàng)業(yè)服務(wù)中心辦公大樓建筑給排水工程設(shè)計(jì),該建筑為高層(十八層)綜合性建筑。給水系統(tǒng)采用分區(qū)供水,地下一層到地上五層為低區(qū),由市政管網(wǎng)直接供水。排水系統(tǒng)采用的是污、廢合流制,底層單獨(dú)排放,排水立管部分設(shè)伸頂通氣管,污水直接排向市政污水管網(wǎng)。建筑雨水系統(tǒng)采用內(nèi)排水的排水方式。設(shè)計(jì)過(guò)程進(jìn)行了各系統(tǒng)方案的確定、平面布置和計(jì)算,以及各種設(shè)備的選型。關(guān)鍵詞:高層建筑 ;給水系統(tǒng);排水系統(tǒng);消火栓滅火系統(tǒng);自動(dòng)噴淋系統(tǒng);雨水系統(tǒng)ABSTRACTThis design is a 18layers buildings named YanLuo Office building in WuHan , pleting the design of the water supply system and draining the system, fire fight system, the hot water systemThe water supply system is applied by vertical division block. The floors from the first to the five are the low areas, water of which is supplied directly by the municipal pipe network. The floors from the sixth to the 11th are the central areas and from the 12th to the 18th are the high areas, water of which are supplied with the frequency conversion pump group. The drainage system is an interflow system of sewerage and waste water. Water of the first floor drains separately, the upright draining pipes are equipped with the ventilating pipes, and then the sewerage is drains to the municipal waste pipe network. The fire fight system design bees to eliminate the fire to bolt to extinguish fire the system, a fire water of the early 10 mins is supply by the fire fight water tank, normal the water supply be pumped by the fire fight Pump from the Saving pond 。 water supply and drainage of buildings。我國(guó)建筑給排水自1949年建國(guó)以來(lái),經(jīng)歷了三個(gè)發(fā)展階段:1.房屋衛(wèi)生技術(shù)設(shè)備階段即初創(chuàng)階段,自1949年至1964《室內(nèi)給水排水和熱水供應(yīng)設(shè)計(jì)規(guī)范》開(kāi)始試行時(shí)為止。第一代通過(guò)專(zhuān)業(yè)培養(yǎng)的建筑給排水專(zhuān)業(yè)技術(shù)人員走上工作崗位,開(kāi)始形成自己的專(zhuān)業(yè)隊(duì)伍。其主要標(biāo)志是通過(guò)工程實(shí)踐,對(duì)以往機(jī)械搬用國(guó)外經(jīng)驗(yàn)并造成失誤進(jìn)行了認(rèn)真總結(jié)和反思,進(jìn)而形成和確立有我國(guó)特色的建筑給排水技術(shù)體系。1986年以來(lái),隨著建筑業(yè)的發(fā)展,建筑給排水專(zhuān)業(yè)迅速發(fā)展,已成為給水排水中不可缺少而又獨(dú)具特色的組成部分。技術(shù)上積累了以前的實(shí)踐經(jīng)驗(yàn)、借鑒了國(guó)外的新技術(shù),專(zhuān)業(yè)技術(shù)有了明顯的突破和發(fā)展,其中消防給水系統(tǒng)在建筑給排水中的發(fā)展尤為突出。近年來(lái),學(xué)術(shù)活動(dòng)踴躍,并加強(qiáng)了國(guó)際間的技術(shù)交流。建筑給排水發(fā)展的快慢直接影響到整個(gè)水工業(yè)發(fā)展 。加上飲用和清潔衛(wèi)生方面的需要,至少需要50200L水才能維持正常的生活。所以,沒(méi)有足夠的生活用水,人們不僅難以維持正常的生活,更談不上提高物質(zhì)文化生活水平。建筑排水工程的任務(wù),主要是把建筑內(nèi)部生活和生產(chǎn)過(guò)程中所產(chǎn)生的污水(廢水)及時(shí)地排到室外排水系統(tǒng)中去,同時(shí)解決屋面雨水的排除問(wèn)題。為改善生活環(huán)境,同時(shí)考慮室內(nèi)外的水景給水排水工程設(shè)計(jì)。高層建筑給水排水工程與一般多層建筑和低層建筑給水排水工程相比,基本理論和計(jì)算方法在某些方面是相同的,但因高層建筑層數(shù)多、建筑高度大、建筑功能廣、建筑結(jié)構(gòu)復(fù)雜,以及所受外界條件的限制等,高層建筑給水排水工程無(wú)論是在技術(shù)深度上,還是廣度上,都超過(guò)了低層建筑物的給水排水工程的范疇,并且有以下一些特點(diǎn)高層建筑給水排水設(shè)備的使用人數(shù)多,瞬時(shí)的給水量和排水流量靠的水源,以及經(jīng)濟(jì)合理的給水排水系統(tǒng)形式,并妥善處理排水管道的通氣問(wèn)題,以保證供水安全可靠、排水通暢和維護(hù)管理方便。給水系統(tǒng)及熱水系統(tǒng)中的靜水壓力很大,為保證管道及配件免受破壞,必須對(duì)給水系統(tǒng)和熱水系統(tǒng)進(jìn)行合理的豎向分區(qū),加設(shè)減壓設(shè)備以及中間和屋頂水箱,使系統(tǒng)運(yùn)行完好。為此,必須設(shè)置安全可靠的室內(nèi)消防給水系統(tǒng),滿足各類(lèi)消防的要求,而且消防給水的設(shè)計(jì)應(yīng)“立足自救”,方可保證及時(shí)撲滅火災(zāi),防止重大事故發(fā)生。以保證管道不漏水,不損壞建筑結(jié)構(gòu)及裝飾,不影響周?chē)h(huán)境,使系統(tǒng)安全運(yùn)行。1.高層建筑生活給水首先,對(duì)適用于高層建筑的生活給水設(shè)計(jì)秒流量計(jì)算方法的研究,一直不斷地在進(jìn)行。用科學(xué)的概率法取代現(xiàn)在仍在使用的平方根法,研究人員在此方面進(jìn)行了不少嘗試。再次,在貯水方面,合建水箱的設(shè)計(jì)方式己越來(lái)越少的被采用,取而代之的是生活水池與消防水池分建的設(shè)計(jì)方式,其中,生活水池也大多傾向于采用不銹鋼板等組合式水箱。新的規(guī)范對(duì)設(shè)置場(chǎng)所危險(xiǎn)等級(jí)、設(shè)計(jì)基本參數(shù)、管道水力計(jì)算等方面都作出了一些調(diào)整。其次,消火栓給水系統(tǒng)也在變頻分級(jí)供水方面進(jìn)行的有益的嘗試和應(yīng)用。排水的輸送已不限于重力流和壓力流,虹吸流出現(xiàn)在壓力(虹吸)式屋面雨水排水系統(tǒng)。建筑也迅猛發(fā)展,各項(xiàng)工程設(shè)計(jì)內(nèi)容豐富。2.室內(nèi)消防設(shè)計(jì)的主要內(nèi)容高層建筑室內(nèi)消防設(shè)計(jì)的主要內(nèi)容有:消火栓系統(tǒng),自動(dòng)噴水滅火系統(tǒng),二氧化碳滅火系統(tǒng),干粉滅火系統(tǒng),鹵代烷滅火系統(tǒng)(現(xiàn)已不讓采用),蒸汽滅火系統(tǒng),煙霧滅火系統(tǒng)等。其中閉式系統(tǒng)中的濕式自動(dòng)噴水滅火系統(tǒng)最為常用。消防水池、水箱的容積確定。消防水泵的流量、揚(yáng)程、型號(hào)和穩(wěn)壓系統(tǒng)的確定。自動(dòng)噴水滅火系統(tǒng)設(shè)計(jì)包括:方案確定。噴頭型號(hào)的確定。報(bào)警閥、水流指示器的選型。自動(dòng)控制系統(tǒng)的確定。3.排水工程設(shè)計(jì)的主要內(nèi)容高層建筑排水工程設(shè)計(jì)內(nèi)容包括:排水體制的確定,排水方案的確定,排水管道系統(tǒng)的布置,排水管道的水力計(jì)算及排水通氣系統(tǒng)的計(jì)算,衛(wèi)生設(shè)備的選型及布置,局部污水處理,構(gòu)筑物的選型,屋面雨水排水系統(tǒng)的確定,排水管材的定型,排水系統(tǒng)施工圖的繪制和施工要求。排水量大等特點(diǎn)。與低層建筑給水排水相比,高層建筑給水排水工程具有以下特點(diǎn):1.高層建筑給水、熱水、消防系統(tǒng)的靜水壓力大,如果只采用一個(gè)區(qū)供水,不僅影響使用,而且管道及配件容易被損壞。 2.高層建筑引發(fā)火災(zāi)的因素多、且火勢(shì)蔓延速度快、火災(zāi)危險(xiǎn)性大、而且撲救較困難。由于目前我國(guó)消防系統(tǒng)設(shè)備能力有限,撲救高層建筑火災(zāi)的難度較大,因此高層建筑的消防系統(tǒng)應(yīng)立足于自救。為了提高排水系統(tǒng)的排水能力,穩(wěn)定管道中的壓力,保護(hù)水封不被破壞,高層建筑的排水系統(tǒng)應(yīng)設(shè)置通氣管系統(tǒng)或采用新型的單立管排水系統(tǒng),另外高層建筑的排水立管應(yīng)采用機(jī)械強(qiáng)度較高的管材,并采用柔性接口。因此,高層建筑必