【正文】
27 母線截面形狀選擇 .............................................................................................. 27 220KV 母線選擇 ................................................................................................... 28 斷路器選擇設(shè)計(jì) ...................................................................................................... 28 斷路器的選擇要求 .............................................................................................. 28 220KV 側(cè)斷路器的選擇 ....................................................................................... 29 隔離開關(guān)選擇設(shè)計(jì) .................................................................................................. 29 隔離開關(guān)選擇要求 .............................................................................................. 29 220KV 側(cè)隔離開關(guān)選擇 ....................................................................................... 29 5 防雷部分設(shè)計(jì) .............................................................................................................. 31 概述 .......................................................................................................................... 31 雷害來源 .............................................................................................................. 31 避雷針作用 .......................................................................................................... 31 雷電過電壓的防護(hù) .................................................................................................. 31 概述 ...................................................................................................................... 31 避雷器的要求及選擇 .......................................................................................... 31 結(jié)論 .................................................................................................................................... 35 致謝 .................................................................................................................................... 36 參考文獻(xiàn) ............................................................................................................................ 37 1 緒 論 由 發(fā)電 、 變電 、 輸電 、 配電 和用電等環(huán)節(jié)組成的電能生產(chǎn)與消費(fèi)系統(tǒng)。 main transformer, the start / standby transformer and the highvoltage transformer factory with the capacity of calculation, the number of models and options。 并作了變壓器保護(hù)。 本文是對配有 4 臺 150MW 汽輪發(fā)電機(jī)的大型火電廠一次部分的初步設(shè)計(jì),主要完成了電氣主接線的設(shè)計(jì)。 所以對于主接線的方式選擇,以及各項(xiàng)參數(shù)的具體計(jì)算,是設(shè)計(jì)中的主要解決內(nèi)容。電力系統(tǒng)要實(shí)現(xiàn)其功能,就需在各個(gè)環(huán)節(jié)和不同層次設(shè)置相應(yīng)的信息與控制系統(tǒng),以便對電能的生產(chǎn)和輸運(yùn)過程進(jìn)行測量、調(diào)節(jié)、控制、保護(hù)、通信和調(diào)度,確保用戶獲得安全 、經(jīng)濟(jì)、優(yōu)質(zhì)的電能。 電氣主接線是發(fā)電廠、變電所電氣設(shè)計(jì)的首要部分,也是構(gòu)成電力系統(tǒng)的重要環(huán)節(jié)。 600MW 區(qū)域 發(fā)電廠電氣部分設(shè)計(jì) 系 別: 機(jī)電與自動(dòng)化學(xué)院 專 業(yè) 班 : 電氣工程及其自動(dòng) 化 姓 名: 學(xué) 號: 指導(dǎo)教師: 2020 年 5 月 600MW 區(qū)域 發(fā)電廠電氣部分設(shè)計(jì) Electrical Design of 600MW Regional Power Plant Ⅰ 摘 要 由發(fā)電、配電、輸電、變電 和用電等環(huán)節(jié)組成的電能生產(chǎn)與消費(fèi)系統(tǒng)。它的功能是將自然界 的一次能源 通過發(fā)電動(dòng)力裝置轉(zhuǎn)化成電能,再經(jīng)輸、變電系統(tǒng)及配電系統(tǒng)將電能供應(yīng)到各負(fù)荷中心。 電能的集中開發(fā)與分散使用,以及電能的連續(xù)供應(yīng)與負(fù)荷的隨機(jī)變化,就制約了電力系統(tǒng)的結(jié)構(gòu)和運(yùn)行。 主接線的確定對電力系統(tǒng)整體及發(fā)電廠、變電所本身的運(yùn)行的可靠性、靈活性和經(jīng)濟(jì)性密切相關(guān)。同時(shí),短路電流和防雷保護(hù)的考慮,也對整個(gè)設(shè)計(jì)有很密切的聯(lián)系,對于這兩個(gè)部分的計(jì)算,也是一個(gè)重點(diǎn)。 設(shè)計(jì)的內(nèi)容部分 包括電氣主接線的形式的比較、選擇;主變壓器、啟動(dòng) /備用變壓器和高壓廠用變壓器容量計(jì)算、臺數(shù)和型號的選擇;短路電流計(jì)算和高壓電氣 設(shè)備的選擇與校驗(yàn) 。 關(guān)鍵詞 : 發(fā)電廠 變壓器 電力系統(tǒng) 繼電保護(hù) 電氣設(shè)備 II Abstract By the power generation, transformation, transmission and distribution of electricity and energy ponents, and other aspects of production and consumption systems. It is the function of the natural world through the power of primary energy into electrical energy power plant, then lost, transforming the system and distribution system will supply power to the load centers. Electrical wiring is the main power plant, electric substation designed first and foremost part of the power system is also constitute an important part. Determination of the main cable on the power system as a whole and power plants, substations to run its reliability, flexibility and economy are closely related. This article is equipped with 4*150MW turbogenerator of largescale thermal power plants a part of the preliminary design of the main pleted the main electrical wiring design. Including the electrical wiring of the main forms of parison, the choice。 shortcircuit current calculation and highvoltage electrical equipment selection and validation。它的功能是將自然界 的 一次能源 通過發(fā)電動(dòng)力裝置(主要包括鍋爐、汽輪機(jī)、發(fā)電機(jī)及電廠輔助生產(chǎn)系統(tǒng)等)轉(zhuǎn)化成電能,再經(jīng)輸、變電系統(tǒng)及配電系統(tǒng)將電能供應(yīng)到各負(fù)荷中心。因此,電能的集中開發(fā)與分散使用,以及電能的連續(xù)供應(yīng)與負(fù)荷的隨機(jī)變化,就制約了電力系統(tǒng)的結(jié)構(gòu)和運(yùn)行。 電能是一種清潔的二次能源。因此,電能已廣泛應(yīng)用于國民經(jīng)濟(jì)、社會(huì)生產(chǎn)和人 民生活的各個(gè)方面。 本設(shè)計(jì)的主要內(nèi)容包括:通過原始資料分析和方案比較,確定發(fā)電廠的電氣主接線。 2 1 設(shè)計(jì)概要 600MW 區(qū)域 發(fā)電廠電氣部分設(shè)計(jì)參數(shù) ( 1) 廠址概況:本廠在一大型煤礦區(qū)內(nèi),為坑口電廠,所有燃料由煤礦直接供給。廠區(qū)地勢較不平坦,地質(zhì)條件好,有新的公 路、鐵路通向礦區(qū),交通方便。 ( 2) 機(jī)組參數(shù): 鍋爐: 1140/670GΗ4 汽機(jī): 535/535/1302020 ??? 發(fā)電機(jī): 2 150 QF QS4 ? ( 3) 電力系統(tǒng)接線圖 ,如圖 11; 圖 11 電力系統(tǒng)接線圖 電力工業(yè)的發(fā)展概況 隨著我國電力事業(yè)迅猛發(fā)展,工程規(guī)模在不斷擴(kuò)大,所采用的電氣設(shè)備在不斷更新?lián)Q代。 自九十年代起,我國陸續(xù)修訂了所有的規(guī)程和規(guī)范,電氣標(biāo)準(zhǔn)全面向 IEC 標(biāo)準(zhǔn)靠攏,并等效地被采用。 3 二十多年來 我們無論是在設(shè)計(jì)標(biāo)準(zhǔn)、設(shè)計(jì)依據(jù)和設(shè)計(jì)方法上,還是在設(shè)計(jì)所選用的先進(jìn)技術(shù)和設(shè)備上都有了騰飛性的發(fā)展。 我國電力行業(yè)發(fā)展方針 目前我國人均擁有裝機(jī)容量和人均占有發(fā)電量較低,技術(shù)經(jīng)濟(jì)指標(biāo)平均水平不高,火電廠的污染物排放 量高,電網(wǎng)相對薄弱,供電可靠性偏低。主要的發(fā)展方針有: ( 1) 積極發(fā)展水電, 水能資源是可再生的、清潔的能源;在電力系統(tǒng)中,有一定比重的水電裝機(jī)容量對系統(tǒng)調(diào)峰和安全經(jīng)濟(jì)運(yùn)行極為有利;水電站的發(fā)電成本低,水庫可以綜合利用。 ( 2) 優(yōu)化發(fā)展火電, 我國有豐富的煤炭、石油和天然氣,火電廠的廠址不受限 制,建設(shè)周期短,能較快發(fā)揮效益。 ( 4) 重點(diǎn)發(fā)展電網(wǎng), 促進(jìn)全國聯(lián)網(wǎng) 。 4 2 電氣主接線設(shè)計(jì) 主接線概述 電氣主接線是發(fā)電廠和變電所電氣部分的主體,它反映各設(shè)備的作用、連接方式和回路的相互關(guān)系。概括地說包括以下五個(gè)方面: ( 1) 可靠性 在研究主接線可靠性時(shí)應(yīng)重視國內(nèi)外長期運(yùn)行的實(shí)踐經(jīng)驗(yàn)和其可靠性的定性分析;主接線的可靠性要包括一次部分和相應(yīng)組成的二次部分在運(yùn)行中可靠性的綜合,在很大程度上也取決于設(shè)備的可靠程度。 ( 2) 靈活性 主接線應(yīng)滿足在調(diào)度、檢修及擴(kuò)建時(shí)的靈活性。 ( 3) 經(jīng)濟(jì)性 要節(jié)省投資,主接線應(yīng)力求簡單,以節(jié)省斷路器、隔離開關(guān)、電流和電壓互感器、避雷器等一次設(shè)備;要節(jié)省繼電保護(hù)和二次回路不過于復(fù)雜,以節(jié)省二次設(shè)備和控制電纜;要能限制短路電流,以便于選擇價(jià)廉的電氣設(shè)備或輕型電器;主接線設(shè)計(jì)要為配電裝置布置創(chuàng)造條件,盡量使占地面 積減少;經(jīng)