【正文】 其變壓器基礎(chǔ)宜按大于變壓器容量的13級(jí)設(shè)計(jì),以便負(fù)荷發(fā)展時(shí),更換變壓器的容量。 主變壓器臺(tái)數(shù)的確定(1)對(duì)大城市郊區(qū)的一次變電所,在中、低壓側(cè)已構(gòu)成環(huán)網(wǎng)的情況下,變電所以裝設(shè)兩臺(tái)主變壓器為宜。(3)同級(jí)電壓的單臺(tái)降壓變壓器容量的級(jí)別不宜太多。(2)根據(jù)變電所所帶負(fù)荷的性質(zhì)和電網(wǎng)結(jié)構(gòu)來確定主變壓器的容量。(2)所用電負(fù)荷所用電負(fù)荷為由于本變電所最低電壓等級(jí)10kV,可直接通過一級(jí)電壓降落,選用兩臺(tái)變壓器,最后降為所用電壓380/220V,查《電力工程電氣設(shè)備手冊(cè):電氣一次部分》,所選變壓器的技術(shù)參數(shù)如表22所示:表22 所用變壓器參數(shù)表型號(hào)額定容量(kVA)額定電壓(kV)阻抗電壓(%)損耗(W)空載電流(%)連接組標(biāo)號(hào)高壓低壓空載短路S9315/103151047003500Y,yn0 主變壓器的選擇 主變壓器選擇的基本原則(1)主變壓器容量一般按變電所建成后5~10年的規(guī)劃負(fù)荷選擇,并適當(dāng)考慮到遠(yuǎn)期1020年的負(fù)荷發(fā)展。電壓降落所用電力變壓器的額定電壓為10/,其高壓側(cè)進(jìn)線分別接于10kV側(cè)母線的Ⅰ段和Ⅱ段,其低壓側(cè)接線采用單母線分段接線方式,平時(shí)分裂運(yùn)行,以限制故障范圍,提高供電可靠性高。本變電所所用電接線設(shè)計(jì),所用電源采用從10kV母線上引接兩個(gè)的方式。 所用電源引接方式當(dāng)所內(nèi)有較低母線時(shí),一般均采用這類母線上引接1~1個(gè)所用電源,這一所用電源引接方式具有經(jīng)濟(jì)和可靠性較高的特點(diǎn)。綜上所述,確定方案一為最佳方案。具有較好的靈活性,也便于擴(kuò)建和發(fā)展。方案二:220kV 雙母線分段,110kV 單母線,10kV 單母線分段。調(diào)試、檢修都較為方便,且便于對(duì)各種電壓等級(jí)接線進(jìn)行擴(kuò)建和發(fā)展。 (4)方案一:220kV 雙母線 110kV 橋形接線 10kV 單母線分段方案二:220kV 雙母線分段 110kV 橋形接線 10kV 單母線分段 電氣主接線方案一 電氣主接線方案二表21 電氣主接線方案比較項(xiàng)目方案可靠性靈活性經(jīng)濟(jì)性方案一:220kV 雙母線,110kV 橋形接線,10kV 單母線分段。當(dāng)只有兩臺(tái)變壓器和兩條線路時(shí),宜采用橋形接線。且根據(jù)變電站220kV運(yùn)行實(shí)際情況(采用SF6斷路器,故障率較低,且采用微機(jī)保護(hù)裝置,檢修周期較長(zhǎng))和技術(shù)發(fā)展趨勢(shì),故220kV本期及遠(yuǎn)景均采用雙母線接線并設(shè)母聯(lián)斷路器。變壓器停運(yùn);當(dāng)線路故障時(shí)允許切除線路、變壓器的數(shù)量等,都直接影響主接線的形式。電氣主接線的設(shè)計(jì)要根據(jù)備用容量的有無而有所不同。(5)考慮備用容量的有無和大小對(duì)主接線的影響。通常對(duì)大型變電所,由于其傳輸容量大,對(duì)供電可靠性要求高,因此,其對(duì)主接線的可靠性、靈活性的要求也高。(4)考慮主變臺(tái)數(shù)對(duì)主接線的影響。對(duì)一級(jí)負(fù)荷,必須有兩個(gè)獨(dú)立電源供電,且當(dāng)一個(gè)電源失去后,應(yīng)保證全部一級(jí)負(fù)荷不間斷供電;對(duì)二級(jí)負(fù)荷,一般要有兩個(gè)電源供電,且當(dāng)一個(gè)電源失去后,能保證大部分二級(jí)負(fù)荷供電。變電所主接線設(shè)計(jì)應(yīng)根據(jù)510年電力系統(tǒng)發(fā)展規(guī)劃進(jìn)行。根據(jù)變電所在電力系統(tǒng)中的地位和作用不同,對(duì)主接線的可靠性、靈活性、經(jīng)濟(jì)性的要求也不同。經(jīng)濟(jì)型主要是投資省、占地面積小、能量損失小??梢匀菀椎膹某跗谶^渡到終期接線,使在擴(kuò)建時(shí),無論一次和二次設(shè)備改造量最小??梢苑奖愕耐_\(yùn)斷路器、母線及其繼電保護(hù)設(shè)備,進(jìn)行安全檢修,且不致影響對(duì)用的供電。可以靈活的投入和切除變壓器、線路,調(diào)配電源和負(fù)荷;能夠滿足系統(tǒng)在事故運(yùn)行方式下、檢修方式下以及特殊運(yùn)行方式下的調(diào)度要求。(2)靈活性。所謂可靠性是指主接線能可靠的工作,以保證對(duì)用戶不間斷的供電。因此,主接線設(shè)計(jì)必須經(jīng)過技術(shù)與經(jīng)濟(jì)的充分論證比較,綜合考慮各個(gè)方面的影響因素,最終得到實(shí)際工程確認(rèn)的最佳方案。主接線代表了發(fā)電廠或變電站高電壓、大電流的電氣部分主體結(jié)構(gòu),是電力系統(tǒng)網(wǎng)絡(luò)結(jié)構(gòu)的重要組成部分。(4)負(fù)荷資料:表11 110kV用戶負(fù)荷統(tǒng)計(jì)資料名 稱最大負(fù)荷(KW)功率因數(shù)回路數(shù)煉鋼廠420002表12 10kV用戶負(fù)荷統(tǒng)計(jì)資料名 稱最大負(fù)荷(KW)功率因數(shù)回路數(shù)煉油廠20002機(jī)械廠9002電機(jī)廠24002飼料廠6002化工廠18002汽車配件廠21002 最大負(fù)荷利用小時(shí)數(shù) Tmax=5500h %。(2)確定本變電所的電壓等級(jí)為避免220/110/10kV,220kV是本變電所的電源電壓,110kV和10kV是二次電壓。 shortcircuit current。關(guān)鍵詞:220kV變電所;主接線;短路電流;配電裝置THE DESIGN OF THE FIRST PART ABOUT THE 220kV TRANSFORMER SUBSTATIONABSTRACTIn this design, based on the given raw data by the task book of the 220kV transformer substation , In accordance with the the requirements of the design point of order and the actual situation of the transformer substation. By considering the security operation,economy and way of paring technical and economic then choose the proper main electrical connection of various kinds voltage, the main transformer and distribution equipment, and by calculating the Shortcircuit current to choose the main electrical equipment and the protection Profile of the main electrical equipment. Besides I have to select the appropriate type of the distribution equipment of the 220kV transformer substation and the position. Graduation project through this time, to a solid《electric power plant parts》theory courses, master substation electrical design part of the basic methods, learning experience and strengthen our foundation and expertise of professional, we apply their training knowledge to analyze and resolve practical issues related to the profession skills, to nurture our independent analysis and problem solving skills. The design includes four parts: original data, design specifications, design calculations and drawings.Key words: 220kV substation。通過本次畢業(yè)設(shè)計(jì),達(dá)到了鞏固《發(fā)電廠電氣部分》課程的理論知識(shí),掌握變電所電氣部分設(shè)計(jì)的基本方法,體驗(yàn)和鞏固我們所學(xué)的專業(yè)基礎(chǔ)和專業(yè)知識(shí),培養(yǎng)我們運(yùn)用所學(xué)知識(shí)去分析和解決與本專業(yè)相關(guān)的實(shí)際問題的能力,培養(yǎng)我們獨(dú)立分析和解決問題的能力。 范文范例參考220kV變電所電氣一次部分設(shè)計(jì)摘要本文以任務(wù)書給定的220kV變電所原始資料為依據(jù),按照變電所設(shè)計(jì)規(guī)程的要求和變電所的實(shí)際情況,從變電所運(yùn)行的安全性,經(jīng)濟(jì)性和可靠性等方面綜合考慮,通過技術(shù)經(jīng)濟(jì)比較對(duì)變電所各種電壓等級(jí)的電氣主接線、主變壓器和配電裝置進(jìn)行了選擇,并在短路電流計(jì)算的基礎(chǔ)上完成了變電所主要電氣設(shè)備的選擇和主要電氣設(shè)備的保護(hù)配置。此外完成了變電所配電裝置的選型和布置設(shè)計(jì)。本設(shè)計(jì)書包括原始資料、設(shè)計(jì)說明書、計(jì)算書和圖紙四部分。 the main connection。 distribution equipment 目 錄1 原始資料 1 題目 1 設(shè)計(jì)資料 12 設(shè)計(jì)說明書 3 電氣主接線 3 主接線設(shè)計(jì)的基本要求 3 主接線的設(shè)計(jì)原則 3 電氣主接線的確定 4 所用電的設(shè)計(jì) 6 所用電的設(shè)計(jì)原則 6 所用電源引接方式 6 所用變壓器的選擇 7 主變壓器的選擇 7 主變壓器選擇的基本原則 8 主變壓器臺(tái)數(shù)的確定 8 主變壓器型式和結(jié)構(gòu)的選擇 8 主變壓器容量的確定 9 主變選擇結(jié)果 9 短路電流計(jì)算 9 短路電流計(jì)算目的 10 短路電流計(jì)算內(nèi)容 10 短路電流計(jì)算結(jié)果 10 主要電氣設(shè)備的選擇 11 主要電氣設(shè)備的選擇要求 11 各電壓等級(jí)電氣設(shè)備的選擇結(jié)果 12 導(dǎo)線選擇 14 防雷設(shè)計(jì) 15 防雷設(shè)計(jì)原則和措施 15 各電壓等級(jí)避雷器選擇結(jié)果 15 16 配電裝置及電氣平面圖 17 配電裝置 17 主變壓器布置 18 電氣平面設(shè)置 183 設(shè)計(jì)計(jì)算書 19 負(fù)荷計(jì)算 19 主變?nèi)萘坑?jì)算 19 主變壓器各繞組電抗標(biāo)幺值計(jì)算 19 短路電流計(jì)算 20 220kV母線短路時(shí)短路電流計(jì)算 21 110kV母線短路時(shí)短路電流計(jì)算 23 10kV母線短路時(shí)短路電流計(jì)算 24 電氣設(shè)備的選擇 26 220kV側(cè)電氣設(shè)備的選擇及校驗(yàn) 26 110kV側(cè)電氣設(shè)備的選擇及校驗(yàn) 29 10kV側(cè)電氣設(shè)備的選擇及校驗(yàn) 32 導(dǎo)線的選擇 36 220kV母線的選擇與校驗(yàn) 36 110kV母線選擇與校驗(yàn) 38 10kV母線選擇與校驗(yàn) 40 避雷器的選擇計(jì)算 41 220kV側(cè)避雷器的選擇校驗(yàn) 42 110kV側(cè)避雷器的選擇校驗(yàn) 42 10kV側(cè)避雷器的選擇校驗(yàn) 42參考文獻(xiàn) 44致謝 45 WORD格式整理 1 原始資料 題目220KV變電所電氣一次部分設(shè)計(jì) 設(shè)計(jì)資料(1)待建變電所在城市近郊,向開發(fā)區(qū)的煉鋼廠供電,在變電所附近有地區(qū)負(fù)荷。(3)待設(shè)計(jì)變電所的電源由雙回220kV線路送到本變電所,在中壓側(cè)110kV母線,送出2回線路,低壓側(cè)10kV母線,送出12回線路,本所220kV線路有三回輸出線路,該變電所的所址,地勢(shì)平坦,交通方便。(5)擬建變電所聯(lián)網(wǎng)情況 待設(shè)計(jì)變電所與電力系統(tǒng)的連接情況2 設(shè)計(jì)說明書 電氣主接線電氣主接線又稱為電氣一次接線,它是將電氣設(shè)備已規(guī)定的圖
點(diǎn)擊復(fù)制文檔內(nèi)容
醫(yī)療健康相關(guān)推薦
文庫吧 www.dybbs8.com
備案圖鄂ICP備17016276號(hào)-1