【正文】
排水衛(wèi)生設(shè)備系統(tǒng),安全可靠的消防給水系統(tǒng),設(shè)置獨(dú)立的消火栓系統(tǒng)及自動(dòng)噴水系統(tǒng),每個(gè)消火栓箱內(nèi)設(shè)按鈕,消防時(shí)直接啟動(dòng)消防泵,生活水泵自動(dòng)啟動(dòng)。本設(shè)計(jì)說明書包含建筑工程設(shè)計(jì)中的生活給水,排水,熱水以及消火栓和自動(dòng)噴水等設(shè)計(jì)項(xiàng)目。prefaceThe main task of this design is in the center of the city, jiangsu province, including water supply and drainage design of the hotel. This is a plex 26 house floor. 1 to 3 layers for the plex building subsidiary recreation, 4 to 26 floors for hotel guest rooms. The rooms and suites are equipped with toilet, ther are seated toilets, bathtubs, sinks in each one. Layer construction area is different, the basement height is m, the layers of high of m, 2 to 3 layers of high of m, 4 to 26 layers of high of m, building a total height of m. Requirements according to the nature of the building, use and construction units, indoor sanitary equipment is equipped with perfect water supply and drainage system, safe and reliable fire protection water supply system, set up independent fire hydrant system and automatic sprinkler system, set button each fire hydrant boxes, fire when directly start the fire pump, water pump automatic start of life. The hotel requirements of this plex indoor hot water supply by centralized hot water supply throughout the whole cycle. This design specification includes construction engineering in the design of the drinking water, drainage, hot water and fire hydrant and sprinkler design projects. Main contents include the drinking water system design and calculation, the calculation in the design of fire hydrant water supply system, the design calculation of spray system, sewage drainage system design and calculation, the hotel water supply and drainage design and calculation of expansion of preliminary design and indoor hot water supply system. 76 目錄前言 1preface 2第一章 設(shè)計(jì)說明 4第一章 設(shè)計(jì)說明 4 4 4 4 5 5 6第2章 設(shè)計(jì)說明 7 72. 2排水系統(tǒng)設(shè)計(jì) 10 11 12 14 17 熱水供應(yīng)系統(tǒng)選擇 17 熱水供應(yīng)系統(tǒng)組成 17 熱水管道的布置與敷設(shè) 17 18 19第3章 給水系統(tǒng)計(jì)算 21 21 22 22 低區(qū)給水管網(wǎng)水力計(jì)算 22 24 26 27 33第4章 熱水系統(tǒng)計(jì)算 35 熱水量計(jì)算 35 熱水量計(jì)算 36 加熱設(shè)備選擇計(jì)算 36 熱水配水管網(wǎng)的水力計(jì)算 37 熱水回水管網(wǎng)的水力計(jì)算 41 選擇循環(huán)水泵 50第5章排水系統(tǒng)的計(jì)算 51 設(shè)計(jì)要點(diǎn) 51 設(shè)計(jì)計(jì)算 51 51 52 53 61——化糞池的設(shè)計(jì)與計(jì)算 62第6章 消火栓系統(tǒng)的計(jì)算 64 64 67 設(shè)計(jì)計(jì)算依據(jù) 67 設(shè)計(jì)計(jì)算 67 消防水池設(shè)計(jì)計(jì)算 67 68. 70第7章 自動(dòng)噴淋系統(tǒng)的計(jì)算 71 71(采用作用面積法) 71 74 74結(jié)論 75參考文獻(xiàn) 76 第一章 設(shè)計(jì)說明世紀(jì)城公寓綜合樓建筑給水排水設(shè)計(jì)包括生活給水系統(tǒng)、生活排水系統(tǒng)、消防系統(tǒng)、熱水供應(yīng)系統(tǒng)等。建筑物為鋼筋混泥土結(jié)構(gòu),其中建筑高度為66米,其各為 ,、。)消防給水要求安全可靠,室內(nèi)各管道盡量采用暗裝。排水條件:室內(nèi)糞便需經(jīng)化糞池處理后進(jìn)入城市管網(wǎng),在樓正北20m處有管徑為DN400的排水管道, 熱源情況:該建筑的熱源來自城市熱力管網(wǎng),熱媒為蒸汽。(用A4紙打印)設(shè)計(jì)圖紙一套① 衛(wèi)生器具的平面布置詳圖。③ 給水、排水、消防、(含自動(dòng)噴灑和消火栓)系統(tǒng)圖。⑤ 泵房、水箱、加熱器房間平面圖。應(yīng)完成的主要內(nèi)容:(一)計(jì)算部分1.建筑給水系統(tǒng)設(shè)計(jì)建筑給水系統(tǒng)設(shè)計(jì)的主要內(nèi)容:確定生活給水設(shè)計(jì)標(biāo)準(zhǔn)與參數(shù)進(jìn)行用水量計(jì)算;選擇給水方式,布置給水管道及設(shè)備;進(jìn)行給水管網(wǎng)水力計(jì)算及室內(nèi)所需水壓的計(jì)算;高位水箱、貯水池容積計(jì)算并確定構(gòu)造尺寸;選擇生活水泵;確定管材及設(shè)備;繪制給水系統(tǒng)的平面圖、系統(tǒng)圖及衛(wèi)生間大樣圖。建筑消火栓系統(tǒng)設(shè)計(jì)的主要內(nèi)容:消防水量計(jì)算;消防給水方式的確定;消防栓、消防管道布置;消防管道水力計(jì)算及消防水壓計(jì)算;消防泵的選擇;確定穩(wěn)壓系統(tǒng);繪制消火栓系統(tǒng)的平面圖及系統(tǒng)圖。3. 建筑排水系統(tǒng)設(shè)計(jì) 建筑排水系統(tǒng)設(shè)計(jì)的主要內(nèi)容:選擇排水體制;確定排水系統(tǒng)的形式和污水處理方法;排水管道水力計(jì)算及通氣系統(tǒng)計(jì)算;屋面雨水排除方式的選擇;雨水管道系統(tǒng)水力計(jì)算;選擇管材及管道安裝;繪制排水系統(tǒng)的平面圖及系統(tǒng)圖。(二)設(shè)計(jì)圖紙建筑給水排水工程平面圖的繪制(1)建筑給水排水平面圖常用比例宜與建筑專業(yè)一致,一般為1:100。(3)安裝在下層空間或埋設(shè)在地面下而為本層使用的管道可繪制于本層平面圖上。管按管道類別和代號(hào)自左至右分別進(jìn)行編號(hào),各樓層應(yīng)一致。(5)引入管、排出管應(yīng)注明與建筑軸線的定位尺寸、穿建筑外墻標(biāo)高。(2)管道布置方向應(yīng)與平面圖一致,并按比例繪制。(3)樓地面線、管道上的附件、閥門等應(yīng)予以表示,管徑立管編號(hào)應(yīng)與平面圖一致。(5)重力流管道要表示坡度方向。(用A4紙打印)設(shè)計(jì)圖紙一套⑥ 衛(wèi)生器具的平面布置詳圖。⑧ 給水、排水、消防、(含自動(dòng)噴灑和消火栓)系統(tǒng)圖。⑩ 泵房、水箱、加熱器房間平面圖。地下室不設(shè)生活給水系統(tǒng)。,水表設(shè)置在管道井里。,浮球閥控制進(jìn)水。4.由《建筑給水排水設(shè)計(jì)規(guī)范》(GB500152005):建筑高度小于24m的公共建筑或小于10層的住宅稱為底層建筑;建筑高度高于或等于24m的公共建筑或高于或等于10層的住宅稱為高層建筑。合理的確定高層建筑給水系統(tǒng)的豎向分區(qū),關(guān)系到給水系統(tǒng)的運(yùn)行、使用、維護(hù)、管理、投資節(jié)能等情況的效果,是高層建筑給水系統(tǒng)的首要環(huán)節(jié)。我國《建筑給水排水設(shè)計(jì)規(guī)范》(GB500152005),, 。貯水池和水泵房設(shè)置在地下一層。世紀(jì)城公寓綜合樓給水系統(tǒng)豎向分為3區(qū),其中低區(qū)由市政管網(wǎng)直接供水,中區(qū)和高區(qū)給水需進(jìn)行二次加壓,中區(qū)和高區(qū)給水方案比較如圖示。其主要優(yōu)缺點(diǎn)見表13?;谏袝桑醪綌M定以下兩個(gè)可行的給水方案進(jìn)行比較選擇。方案Ⅱ:整個(gè)系統(tǒng)采用水泵水箱減壓閥分區(qū)給水方式,低區(qū)有市政管網(wǎng)直接供水,中高區(qū)用水全部有設(shè)置在地下層的水泵提升至屋頂水箱,然后再分至各區(qū)的橫管上,中區(qū)采用減壓閥減壓。缺點(diǎn):水泵型號(hào)及臺(tái)數(shù)較多;投資較大;水泵控制及調(diào)節(jié)較麻煩。缺點(diǎn):生活用水在水箱停用,對水質(zhì)有影響,水泵揚(yáng)程大提升管所承受的壓力大,屋頂水箱對建筑結(jié)構(gòu)有較大的要求。經(jīng)濟(jì)方面,方案Ⅰ能源消耗較省,管網(wǎng)較簡單,較方案Ⅱ經(jīng)濟(jì)。水質(zhì)方面,方案Ⅰ較方案Ⅱ水質(zhì)好,可達(dá)到生活飲用水水質(zhì)的要求;而方案Ⅱ要在高位水箱的出口進(jìn)行一定的處理或加強(qiáng)屋頂水箱的衛(wèi)生管理,才可達(dá)到生活飲用水水質(zhì)的要求。考慮到盡量利用市政管網(wǎng)供水壓力及保證供水安全可靠,簡化設(shè)備與管道,確定以上的豎向分區(qū)結(jié)果.。7. 低區(qū)給水系統(tǒng)利用市政管網(wǎng)壓力直接供水,采用下行上給的供水方式,枝狀管網(wǎng)、橫干管敷設(shè)于地下一層的天花板下,給水立管布置在墻角、柱邊,并由土建裝飾處理。2. 2排水系統(tǒng)設(shè)計(jì),廚房采用單立管排水系統(tǒng)。污水經(jīng)地下室1層樓板下排出室外。污水在室外匯合后經(jīng)化糞池處理后排入市政污水管道。地下層集水坑內(nèi)設(shè)2臺(tái)潛水泵,一用一備,交替運(yùn)行,潛水泵由集水坑水位自動(dòng)控制,當(dāng)一臺(tái)水泵來不及排水使水位達(dá)到報(bào)警水位時(shí),兩臺(tái)水泵同時(shí)工作并報(bào)警。(1)分流制:指糞便污水與生活廢水,生產(chǎn)污水與生產(chǎn)廢水在建筑內(nèi)分別排至建筑物外。5. 管道安裝時(shí),管道不得穿越臥式、病房等對衛(wèi)生、安靜要求較高的房間,并不宜靠近與臥式相鄰的內(nèi)墻;商品住宅衛(wèi)生間的衛(wèi)生器具排水管不宜穿越樓板進(jìn)入他戶;排水立管僅設(shè)置伸頂通氣管時(shí),最低排水橫支管與立管連接處距排水立管管底垂直距離小于表中規(guī)定的最小距離時(shí),底部支管應(yīng)單獨(dú)排出。建筑生活排水管道管材的選擇,應(yīng)綜合考慮建筑物的使用性質(zhì)、建筑高度、抗震要求、防火要求及當(dāng)?shù)氐墓懿墓?yīng)條件,因地制宜選用。建筑物內(nèi)排水管道應(yīng)采用建筑排水塑料管及管件或柔性接口機(jī)制排水鑄鐵管及相應(yīng)管件。 盡管排水鑄鐵管的優(yōu)點(diǎn)甚多,然而隨著經(jīng)濟(jì)的迅猛發(fā)展,人們的生活水平、環(huán)保意識(shí)不斷提高,傳統(tǒng)的鑄鐵排水管材因?yàn)椴荒軡M足現(xiàn)代環(huán)保要求,已逐漸被淘汰。 UPVC管材具有重量輕、耐腐蝕、強(qiáng)度較高等優(yōu)點(diǎn),因而在管道安裝中應(yīng)用廣泛。UPVC管材內(nèi)壁光滑,流體摩擦阻力小,克服了鑄鐵管因生銹、結(jié)垢而影響流量的缺陷。 消防泵房設(shè)在地下2層,消防貯水池也設(shè)置在地下2層。根據(jù)設(shè)計(jì)資料,參照《高層民用建筑設(shè)計(jì)防火規(guī)范》(CB5004595)(2005年版)。世紀(jì)城公寓同一時(shí)間的滅火次數(shù)按1次計(jì)。該系統(tǒng)中消火栓系統(tǒng)設(shè)置兩套水泵接合器。樓內(nèi)消火栓用水由消火栓系統(tǒng)加壓泵直接加壓供水。(3)結(jié)合《高層民用建筑設(shè)計(jì)防火規(guī)范》(CB5004595)(2005年版):,應(yīng)采取分區(qū)給水系統(tǒng)。因此該系統(tǒng)不分區(qū)。消防結(jié)束后手動(dòng)停泵。(6)室內(nèi)消防給水系統(tǒng)應(yīng)與生活、生產(chǎn)給水系統(tǒng)分開獨(dú)立設(shè)置。室內(nèi)消防給水環(huán)狀管網(wǎng)的進(jìn)水管和區(qū)域高壓或臨時(shí)高壓給水系統(tǒng)的引人管不應(yīng)少于兩根,當(dāng)其中一根發(fā)生故障時(shí),其余的進(jìn)水管或引入管應(yīng)能保證消防用水量和水壓的要求。每根消防豎管的直徑應(yīng)按通過的流量經(jīng)計(jì)算確定,但不應(yīng)小于100mm。應(yīng)采取減壓措施。消火栓的栓口直徑應(yīng)為65mm,水帶長度不應(yīng)超過25m,水槍噴嘴口徑不應(yīng)小于19mm。(11) 高位消防水箱的設(shè)置高度應(yīng)保證最不利點(diǎn)消火栓靜水壓力。當(dāng)高位消防水箱不能滿足上述靜壓要求時(shí),應(yīng)設(shè)增壓設(shè)施。(13)根據(jù)《高層民用建筑設(shè)計(jì)防火規(guī)范》,高層建筑內(nèi)的商業(yè)營業(yè)廳、展覽廳等,當(dāng)設(shè)有火災(zāi)自動(dòng)報(bào)警系統(tǒng)和自動(dòng)滅火系統(tǒng),且采用不燃燒或難燃燒材料裝修時(shí),地上部分防火分區(qū)的允許最大建筑面積為4000m2;地下部分防火分區(qū)的允許最大建筑面積為2000m2。(14)根據(jù)《汽車庫、修車庫、停車場設(shè)計(jì)防火規(guī)范》,汽車庫應(yīng)設(shè)防火墻劃分防火分區(qū)。 表24因此,地下停下場每層需分為兩個(gè)防火分區(qū)。根據(jù)噴頭的常開、開閉形式和管網(wǎng)充水與否分下列幾種自動(dòng)噴水滅火系統(tǒng)。該系統(tǒng)有滅火及時(shí),撲救效率高的優(yōu)點(diǎn)。該系統(tǒng)適用于環(huán)境溫度為4℃t70℃的建筑物。該系統(tǒng)滅火時(shí)需先排氣,故噴頭出水不如濕式系統(tǒng)及時(shí)。為減少排氣時(shí)間,一般要求管網(wǎng)的容積不大于200L。⑷雨淋噴水滅火系統(tǒng)為噴頭常開的滅火系統(tǒng),當(dāng)建筑物發(fā)生火災(zāi)時(shí),由自動(dòng)控制裝置打開集中控制閘門,使整個(gè)保護(hù)區(qū)域所有噴頭噴水滅火。適用于火災(zāi)蔓延快、危險(xiǎn)性大的建筑。該系統(tǒng)使用于需防火隔離的開口位置。是通過熱敏釋放機(jī)構(gòu)的動(dòng)作而噴水。噴頭根據(jù)感溫元件、溫度等級(jí)、濺水盤形式進(jìn)行分類。除吊頂噴頭及吊頂下安裝的噴頭外,直立型、下垂型標(biāo)準(zhǔn)噴頭,其濺水盤與頂板的距離不應(yīng)小于75mm,且不應(yīng)大于150mm。⑴室內(nèi)供水管應(yīng)布置成環(huán)狀,其進(jìn)水管不宜少于2條,當(dāng)其中1條進(jìn)水管發(fā)生故障時(shí),其余進(jìn)水管應(yīng)仍能保證全部用水量和水壓;⑵每個(gè)自動(dòng)噴水滅火系統(tǒng),應(yīng)增設(shè)水流指示器、壓力開關(guān)等輔助電動(dòng)報(bào)警裝置;⑶~,沒有冰凍危險(xiǎn)、管理維護(hù)方便的房間內(nèi);⑷供水干管應(yīng)設(shè)分隔閥門,設(shè)在便于維修的地方,并經(jīng)常處于啟動(dòng)狀態(tài);⑸自動(dòng)噴水滅火系統(tǒng)應(yīng)設(shè)水泵接合器,一般不宜少于2個(gè);⑹在自動(dòng)噴水滅火系統(tǒng)報(bào)警閥后的管網(wǎng)與室內(nèi)消火栓給水管水管網(wǎng)分開設(shè)置;⑺自動(dòng)噴水滅火系統(tǒng)應(yīng)設(shè)泄水裝置;⑻溫式和預(yù)作用自動(dòng)噴水滅火系統(tǒng)的每個(gè)報(bào)警閥控制噴頭數(shù)不宜超過800個(gè),有排氣裝置的干式