【正文】 XV450 ,空氣明敷/架空線路時(shí)其安全載流量為158A。室外架空銅芯導(dǎo)線按機(jī)械強(qiáng)度的最小截面為10mm2,滿足要求。分配箱至開(kāi)關(guān)箱,開(kāi)關(guān)箱至用電設(shè)備的導(dǎo)線敷設(shè)采用銅橡皮絕緣導(dǎo)線空氣明敷/架空線路,室外架空銅導(dǎo)線按機(jī)械強(qiáng)度的最小截面為10mm2。(4)按照《JGJ462005》規(guī)定制定施工組織設(shè)計(jì),接地電阻R≤4Ω。(3)根據(jù)施工現(xiàn)場(chǎng)用電設(shè)備布置情況,總箱進(jìn)線采用導(dǎo)線空氣明敷/架空線路敷設(shè),干線采用空氣明敷/架空線路敷設(shè),用電器導(dǎo)線采用空氣明敷/架空線路敷設(shè)。主體工程主要為磚砌體工程和混凝土工程,需用設(shè)備負(fù)荷見(jiàn)下:序號(hào) 機(jī)具名稱 型號(hào) 安裝功率(kW) 數(shù)量 合計(jì)功率(kW)1 塔式起重機(jī) QT40(TQ26) 48 1 48 2 鋼筋調(diào)直機(jī) GT4/14 4 1 4 3 鋼筋切斷機(jī) QJ401 1 4 高壓汞燈 3 1 3 5 碘鎢燈 1 2 2 6 砂漿攪拌機(jī) JD150 1 7 插入式振動(dòng)器 ZX50 2 8 交流電焊機(jī) BX35002 1 設(shè)計(jì)計(jì)算 1)現(xiàn)場(chǎng)勘探及初步設(shè)計(jì):(1)本工程所在施工現(xiàn)場(chǎng)范圍內(nèi)施工前無(wú)各種埋地管線。結(jié)構(gòu)類(lèi)型:框剪結(jié)構(gòu)工期安排:300天質(zhì)量等級(jí):合格工程安全文明施工目標(biāo):安全質(zhì)量標(biāo)準(zhǔn)化合格工程監(jiān)理單位:石門(mén)縣梯云建設(shè)監(jiān)理有限責(zé)任公司二、編制依據(jù)《低壓配電設(shè)計(jì)規(guī)范》GB5005495《建筑工程施工現(xiàn)場(chǎng)供電安全規(guī)范》GB5019493《通用用電設(shè)備配電設(shè)計(jì)規(guī)范》GB5005593《供配電系統(tǒng)設(shè)計(jì)規(guī)范》GB5005295《施工現(xiàn)場(chǎng)臨時(shí)用電安全技術(shù)規(guī)范》JGJ462005《建筑施工安全檢查標(biāo)準(zhǔn)》JGJ5999 石門(mén)縣麒麟街農(nóng)貿(mào)市場(chǎng)二期1樓工程施工圖紙和施工現(xiàn)場(chǎng)平面布置圖 石門(mén)縣麒麟街農(nóng)貿(mào)市場(chǎng)二期1樓工程施工組織設(shè)計(jì) 三、實(shí)施范圍: 本專項(xiàng)方案的編制在于指導(dǎo)、控制現(xiàn)場(chǎng)臨時(shí)用電的安全,指導(dǎo)、約束施工人員認(rèn)真執(zhí)行每一個(gè)安全施工指令和作業(yè)方法。石門(mén)縣麒麟街農(nóng)貿(mào)市場(chǎng)二期1樓臨時(shí)用電專項(xiàng)方案石門(mén)縣第五建筑工程有限公司二零一五年七月專項(xiàng)施工方案報(bào)審表 工程名稱:石門(mén)縣麒麟街農(nóng)貿(mào)市場(chǎng)二期1樓 致:石門(mén)縣梯云建設(shè)監(jiān)理有限責(zé)任公司 (監(jiān)理單位)我方已根據(jù)施工合同的有關(guān)規(guī)定完成了石門(mén)縣麒麟街農(nóng)貿(mào)市場(chǎng)二期1樓工程建設(shè)工程臨時(shí)用電專項(xiàng)施工方案的編制,并經(jīng)我單位上級(jí)技術(shù)負(fù)責(zé)人審查批準(zhǔn),請(qǐng)予以審查。附:臨時(shí)用電專項(xiàng)施工方案承包單位(章): 石門(mén)縣第五建筑工程有限公司 項(xiàng) 目 經(jīng) 理 日 期: 專業(yè)監(jiān)理工程師審查意見(jiàn):專業(yè)監(jiān)理工程: 日 期: 總監(jiān)理工程師審查意見(jiàn):項(xiàng)目監(jiān)理機(jī)構(gòu): 總監(jiān)理工程師: 日 期: 專項(xiàng)施工方案審核表項(xiàng)目名稱:石門(mén)縣麒麟街農(nóng)貿(mào)市場(chǎng)二期1樓編制審核部門(mén)審核意見(jiàn)備注項(xiàng)目部編制人:審核意見(jiàn): 審核人: 年 月 日公司工程部審核意見(jiàn): 審核人 : 年 月 日公司技術(shù)負(fù)責(zé)人審定意見(jiàn):審核人 : 年 月 日臨時(shí)用電專項(xiàng)施工方案一、工程概況工程名稱:石門(mén)縣麒麟街農(nóng)貿(mào)市場(chǎng)二期1樓建設(shè)單位:石門(mén)縣第五建筑工程有限公司設(shè)計(jì)單位:石門(mén)典澧建筑勘察設(shè)計(jì)院有限公司工程地點(diǎn):石門(mén)縣麒麟街工程規(guī)模:該工程總建筑面積約4990m2,建筑層數(shù)十一層。四、方案選擇用電設(shè)備基本情況本工程主體工程混凝土、磚砌體工程量較大,現(xiàn)場(chǎng)用電量主要集中在主體工程階段,則臨時(shí)用電方案依據(jù)主體工程所須用電量參考。(2)現(xiàn)場(chǎng)采用380V低壓供電,設(shè)一配電總箱,內(nèi)有計(jì)量設(shè)備,采用TNS系統(tǒng)供電。布置位置及線路走向參見(jiàn)臨時(shí)配電系統(tǒng)圖及現(xiàn)場(chǎng)平面圖,采用三級(jí)配電,三級(jí)防護(hù)。2)確定用電負(fù)荷:(1)、塔式起重機(jī)Kx = Cosφ = tgφ = 將Jc =40%統(tǒng)一換算到Jc1 =25%的額定容量Pn = 48kWPe = n(Jc/Jc1)1/2Pn = 1()1/248 = kWPjs = KxPe = = Qjs = Pjs tgφ= = kvar(2)、鋼筋調(diào)直機(jī)Kx = Cosφ = tgφ = Pjs = 4 = kWQjs = Pjs tgφ= = kvar(3)、鋼筋切斷機(jī)Kx = Cosφ = tgφ = Pjs = = kWQjs = Pjs tgφ= = kvar(4)、高壓汞燈Kx = Cosφ = tgφ = Pjs = 3 = kWQjs = Pjs tgφ= = kvar(5)、碘鎢燈Kx = Cosφ = tgφ = Pjs = 11 = kWQjs = Pjs tgφ= = kvar(6)、碘鎢燈Kx = Cosφ = tgφ = Pjs = 11 = kWQjs = Pjs tgφ= = kvar(7)、自落式混凝土攪拌機(jī)Kx = Cosφ = tgφ = Pjs = = kWQjs = Pjs tgφ= = kvar(8)、插入式振動(dòng)器Kx = Cosφ = tgφ = Pjs = = kWQjs = Pjs tgφ= = kvar(9)、插入式振動(dòng)器Kx = Cosφ = tgφ = Pjs = = kWQjs = Pjs tgφ= = kvar(10)、交流電焊機(jī)Kx = Cosφ = tgφ = 將Jc =50%統(tǒng)一換算到Jc1 =100%的額定容量Pn = Sn Cosφ = =Pe = n(Jc/Jc1)1/2Pn = 1()1/2 = kWPjs = KxPe = = Qjs = Pjs tgφ= = kvar(11)總的計(jì)算負(fù)荷計(jì)算,總箱同期系數(shù)取 Kx = 總的有功功率Pjs = KxΣPjs = (+++++++++) = kW總的無(wú)功功率Qjs = KxΣQjs =(+++++++++) = kvar總的視在功率Sjs = ( Pjs2+Qjs2 )1/2 = (+)1/2 = kVA總的計(jì)算電流計(jì)算Ijs = Sjs/(Ue) = () = A3)、塔吊分配電箱線路上導(dǎo)線截面及分配箱、開(kāi)關(guān)箱內(nèi)電氣設(shè)備選擇:在選擇前應(yīng)對(duì)照平面圖和系統(tǒng)圖先由用電設(shè)備至開(kāi)關(guān)箱計(jì)算,再由開(kāi)關(guān)箱至分配箱計(jì)算,選擇導(dǎo)線及開(kāi)關(guān)設(shè)備。(1)、塔式起重機(jī)開(kāi)關(guān)箱至塔式起重機(jī)導(dǎo)線截面及開(kāi)關(guān)箱內(nèi)電氣設(shè)備選擇(開(kāi)關(guān)箱以下用電器啟動(dòng)后需要系數(shù)取1):i)計(jì)算電流Kx = 1 Cosφ = tgφ = Ijs = Kx Pe /(Ue Cosφ) = () = ii)選擇導(dǎo)線選擇XV450 ,空氣明敷/架空線路時(shí)其安全載流量為158A。iii)選擇電氣設(shè)備選擇開(kāi)關(guān)箱內(nèi)隔離開(kāi)關(guān)為DZ10250/3 ,其脫扣器整定電流值為Ir = 200A,漏電保護(hù)器為 DZ10L250/3。iii)選擇電氣設(shè)備選擇分配箱內(nèi)開(kāi)關(guān)為DZ10250/3 ,其脫扣器整定電流值為Ir = 200A,漏電保護(hù)器為 DZ10L250/3。iii)選擇電氣設(shè)備選擇分配箱內(nèi)開(kāi)關(guān)為DZ10250/3 ,其脫扣器整定電流值為Ir = 200A,漏電保護(hù)器為 DZ10L250/3。ii)選擇出線開(kāi)關(guān)塔吊分配電箱出線開(kāi)關(guān)選擇DZ10250/3 ,其脫扣器整定電流值為Ir = 200A,漏電保護(hù)器為 DZ10L250/3。分配箱至開(kāi)關(guān)箱,開(kāi)關(guān)箱至用電設(shè)備的導(dǎo)線敷設(shè)采用銅橡皮絕緣導(dǎo)線空氣明敷/架空線路,室外架空銅導(dǎo)線按機(jī)械強(qiáng)度的最小截面為10mm2。室外架空銅芯導(dǎo)線按機(jī)械強(qiáng)度的最小截面為10mm2,滿足要求。(2)、鋼筋切斷機(jī)開(kāi)關(guān)箱至鋼筋切斷機(jī)導(dǎo)線截面及開(kāi)關(guān)箱內(nèi)電氣設(shè)備選擇(開(kāi)關(guān)箱以下用電器啟動(dòng)后需要系數(shù)取1):i)計(jì)算電流Kx = 1 Cosφ = tgφ = Ijs = Kx Pe /(Ue Cosφ) = () = ii)選擇導(dǎo)線選擇XV410 ,空氣明敷/架空線路時(shí)其安全載流量為57A。iii)選擇電氣設(shè)備選擇開(kāi)關(guān)箱內(nèi)隔離開(kāi)關(guān)為Hk115/3,漏電保護(hù)器為 DZ15L100/30。iii)選擇電氣設(shè)備選擇分配箱內(nèi)開(kāi)關(guān)為DZ520/3 ,其脫扣器整定電流值為Ir = 16A,漏電保護(hù)器為 DZ15L100/30。iii)選擇電氣設(shè)備選擇分配箱內(nèi)開(kāi)關(guān)為DZ520/3 ,其脫扣器整定電流值為Ir = 16A,漏電保護(hù)器為 DZ1
點(diǎn)擊復(fù)制文檔內(nèi)容
公司管理相關(guān)推薦
文庫(kù)吧 www.dybbs8.com
備案圖鄂ICP備17016276號(hào)-1