【正文】
uous advancement and development of technology user requirements for power quality and higher, and the voltage offset direct effect on the quality of electricity. In the power system, the substation occupies an important position, because many of the power system operation and running is pleted within the substation, it is necessary to choose a reasonable voltage and reactive power control strategy for stable operation of the substation. In this paper, monly used substation transformer load tap and pensation capacitor switching method of adjusting to do a brief introduction, and designs the basic control scheme. First, a brief introduction on the Ninth Region Plot control of voltage and reactive power integrated control strategy design, and at about ninezone diagram control policy shortings. In order to improve its shortings by adding two vibrationproof papers presents an improved cell ninezone diagram control strategy. With the traditional ninezone diagram control strategy pared, the former waiting to run point out the antivibration area, although at the expense of reactive indicators was to ensure that the qualified voltage quality, and avoid the phenomenon of shock action. Voltage and Reactive Power Integrated controller has a strong antijamming capability, easy with industrial systems as a whole, to expand its capabilities S7300PLC as the master unit, according to digital acquisition circuits and analog acquisition circuit acquires the parameters required voltage and reactive power control. In order to improve control reliability, requires hardware control and software control bination, this article developed a corresponding software control flow chart. Key Words: Substations; voltage; reactive power; ninearea control strategy; the programmable controller 北華大學畢業(yè)設(shè)計(論文) 3 目 錄 摘 要 ................................................................................................ 1 Abstract ................................................................................................... 2 1 緒論 ..................................................................................................... 1 選題背景和意義 .......................................................................... 1 國內(nèi)外研究現(xiàn)狀 .......................................................................... 1 本文主要工作 .............................................................................. 2 2 變電站電壓無功綜合控制原理 ........................................................ 3 電壓無功控制的基本原理 ........................................................... 3 變電站電壓無功綜合控制的實現(xiàn)方法 ........................................ 3 九區(qū)圖控制策略 .......................................................................... 3 九區(qū)圖基本原理 ..................................................................................... 5 ......................................................................... 7 九區(qū)圖控制策略其他缺陷 .................................................................... 10 改進九區(qū)圖控制策略 ................................................................ 11 3 綜合控制裝置的硬件設(shè)計 .............................................................. 14 控制系統(tǒng)主電路設(shè)計 ................................................................ 14 控制裝置硬件設(shè)計 .................................................................... 15 PLC 概述 .................................................................................... 15 PLC 的組成 ............................................................................................ 16 數(shù)據(jù)采集 ................................................................................... 17 北華大學畢業(yè)設(shè)計(論文) 4 開關(guān)量的采集 ....................................................................................... 17 模擬量的采集 ....................................................................................... 17 交流采樣的算法 ................................................................................... 19 控制裝置設(shè)計 ............................................................................ 24 變壓器檔位調(diào)整控制電路 .................................................................... 24 電容器接線方案 ................................................................................... 25 基于 PLC 控制的外部接線原理圖 ............................................ 26 4 控制裝置軟件設(shè)計 .......................................................................... 28 主程序設(shè)計 ............................................................................... 28 各子程序功能模塊的實現(xiàn) ......................................................... 31 結(jié) 論 .......................................................................................... 38 參 考 文 獻 ........................................................................................ 39 附錄 A 基于 PLC 控制的外部接線原理圖 .................................... 40 致 謝 .............................................................................................. 41 北華大學畢業(yè)設(shè)計(論文) 1 1 緒論 選題背景和意義 在 電力系統(tǒng)中 電壓是衡量電能質(zhì)量 好壞 一個 及其 重要的指標 , 電壓 大小 是否 穩(wěn)定不僅關(guān)系到電力系統(tǒng)本身 運行 的安全 , 而且 還影響 到 生活中 千千萬萬的用戶 。 變電站電壓無功綜合控制器以有很強的抗干擾能力,易于與工業(yè)系統(tǒng)連成一個整體、易于擴充其功能的 S7300PLC作為主控單元,根據(jù)開關(guān)量采集電路和模擬量采集電路獲取所需參數(shù)進行電壓無功控制。 本文就目前變電站常用的調(diào)節(jié)有載變壓器的分接頭與投切補償電容器的方法做了簡介,并設(shè)計了基本的控制方案。北華大學畢業(yè)設(shè)計(論文) 1 摘 要 隨著科技的不斷進步與發(fā)展,用戶對電能質(zhì)量的要求越來越高,而電壓偏移的大小直接影響電能的質(zhì)量。 在 電力系統(tǒng) 中,變電站占有重要地位 , 因為電力系統(tǒng)中很多操作運行 是在變電站內(nèi)完成,所以選取合理地 電壓無功控制策略對變電站的穩(wěn)定運行是非常必要的。 首先簡單的 介紹了 基于 九區(qū)圖控制策略 的變電站電壓無功綜合控制設(shè)計 以及 有關(guān)于九區(qū)圖控制策略 的不足之處, 為了改善其不足之處本文提出通過增加兩個防振小區(qū)的改進九區(qū)圖控制策略 , 與 傳統(tǒng)九區(qū)圖控制策略相比而言,前者等待運行點出防振小區(qū),雖然犧牲了無功指標卻保證了電壓質(zhì)量的合格,而且避免產(chǎn)生震蕩的動作現(xiàn)象。為了提高控制可靠性,需要硬件控制與軟件控制相結(jié)合,于此本文編制了相應(yīng)的軟件控制流程圖。 如果 電壓偏移過大不僅 嚴重影響了 用戶的正常 生活與工業(yè)生產(chǎn) ,還 有 可能使 電力系統(tǒng)網(wǎng)絡(luò) 損耗增大, 嚴重的情況下將會 危害 到電力 系統(tǒng) 穩(wěn)定 運行。 于此 同時 人們也開始廣泛關(guān)注 電力 系統(tǒng) 網(wǎng) 絡(luò) 中的 電壓無功綜合控制問題。 又由于 大多數(shù)電力電子裝置 具有較低 的功率因數(shù), 所以 它們 在工作的過程中 所消耗的無功功率在電 網(wǎng)所輸送的電 能 中 將會 占有很大的 一部分的 比例。 因此在變電站中 合理的位置安裝 電壓、無功綜合控制器, 可以 根據(jù) 電力系統(tǒng) 運行情況 對 本 變電 站的電壓和無功 進行自動控制