【正文】
車輛與動力工程學院畢業(yè)設(shè)計說明書 IV 167。 風口的布置 ................................................................................................. 25 167。 新風機組的選型 ........................................................................................ 24 第六章 空調(diào)風系統(tǒng) .................................................................................................... 25 167。 辦公樓新風冷負荷計算書 ........................................................... 16 第五章 風機盤管加新風系統(tǒng)選型計算 .................................................................. 21 167。 辦公樓新風量和新風負荷的確定 ......................................................... 15 167。 辦公樓圍護結(jié)構(gòu)冷負 荷計算 ................................................................... 11 167。 設(shè)備散熱形成的冷負荷 ................................................................. 9 167。 室內(nèi)傳熱維護瞬時冷負荷 ............................................................. 8 167。 圍護結(jié)構(gòu)瞬變冷負荷計算原理 ................................................................ 8 167。 室外設(shè)計參數(shù) .............................................................................................. 6 167。 建筑特點 ....................................................................................................... 5 167。 the plan of the insulation of air duct and chilled water pipes。 the estimation of air distribution method and the selection of relevant equipments。. The height of the first floor is me ters,and the other three floor’heights are all meters. The aircondition system is designed to supply cool air in summer, and a fan coil units (FCUs)fresh air system is selected and central screw water chillers are used to provide the chilling water needed. In winter, the municipal central heating system is used to supply heat and keep official room warm. Some of the main points in this design are given as follows: To design an appropriate airconditioning system for the building, the overall analysis is important. This includes the calculation, such as cooling load calculation, the estimation of system zoning。并根據(jù)所選擇的空調(diào)機組選配合適的輔助設(shè)備:冷凍水循環(huán)水泵,冷卻水循環(huán)水泵,開式水箱,冷卻水塔,及相應的水管風管閥門等。除此之外,還需要進行空調(diào)末端處理設(shè)備及機房輔助設(shè)備及的選型。設(shè)計的空調(diào)系統(tǒng)采用風機盤管 — 新風系統(tǒng) ,選用水冷機組制冷凍水供冷,冬季依靠市政集中供熱采暖。首層凈高 ,其他三層凈高均為 。車輛與動力工程學院畢業(yè)設(shè)計說明書 I 辦公樓中央空調(diào)設(shè)計 摘 要 本設(shè)計為天津市 XX公司辦公樓中央空調(diào)系統(tǒng) ,擬為之設(shè)計合理的中央空調(diào)系統(tǒng) ,為室內(nèi)工作人員提供舒適的工作環(huán)境。建筑共四層,總面積為178。要求采用空調(diào)夏季制冷冬季供暖。 設(shè)計的內(nèi)容包括:選定合適空調(diào)系統(tǒng)的類型并確定設(shè)計方案,計算部分也十分重要,例如:空調(diào)冷負荷的計算;空調(diào)系統(tǒng)的劃分與系統(tǒng)方案的確定;冷源的選擇;風系統(tǒng)的設(shè)計與計算;室內(nèi)送風 方式與氣流組織形式的選定;水系統(tǒng)的設(shè)計、布置與水力計算; 風管系統(tǒng)與水管系統(tǒng)保溫層的設(shè)計等內(nèi)容。需要結(jié)合所選擇的空調(diào)系統(tǒng)的特點及辦公樓的建筑結(jié)構(gòu)選擇合適的空調(diào)機組及末端設(shè)備,合理的布置吊頂內(nèi)風管與水管的位置。 關(guān)鍵詞 :辦公樓,中央空調(diào),水冷機組,風機盤管 — 新風系統(tǒng) 車輛與動力工程學院畢業(yè)設(shè)計說明書 II THE CENTRAL AIRCONDITION OF OFFICIAL BUILDING ABSTRACT The design of central airconditioning system for the building of a Tianjin pany is aimed to get a fortable working condition indoors. The total area of the building is m178。 the design of air duct system and calculation。 the design of water system and the analysis of its resistance losses。 etc.. Meanwhile, equipment selection is also an essential part of the design. According to the requirement, a fan coil units (FCUs)fresh air system is appropriate. Thus, the main process equipment, . the chiller, the fan coil units, the circulating water pumps, the cooling tower, are also determined in the design considering their characteristics and working conditions. KEY WORDS: official building, central air conditioning, cooling water chiller fan coil units (FCUs)fresh air system 車輛與動力工程學院畢業(yè)設(shè)計說明書 III 目 錄 第一章 緒 論 ................................................................................................................. 1 第二章 系統(tǒng)方案的選擇確定 ..................................................................................... 3 第三章 工程概況 .......................................................................................................... 5 167。 建筑相關(guān)資料 .............................................................................................. 5 167。 室內(nèi)設(shè)計參數(shù) .............................................................................................. 7 第四章 空調(diào)負荷計算 .................................................................................................. 8 167。 外墻和屋面瞬變傳熱引起的冷負荷 ............................................ 8 167。 外窗瞬變傳熱引起的冷負荷 ......................................................... 9 167。 新風冷負荷 ......................................................................................11 167。 各房間送風方式的確定 ........................................................................... 14 167。 新風負荷計算舉例 ........................................................................ 15 167。 風機盤管系統(tǒng)選型計算 ........................................................................... 21 167。 空調(diào)房間氣流組織 .................................................................................... 25 167。 新風入口注意事項 ........................................................................ 25 167。 新、排風口的防雨百葉尺寸的確定 .......................................... 26 167。 送風口的布置原則 ........................................................................ 27 167。 新風管的設(shè)計計算 ................................................................................... 28 167。 空調(diào)水系統(tǒng)的選型比較 .......................................................................... 32 167。 風機盤管水系統(tǒng)水力計算 ....................................................................... 33 167。 標準層的冷凍水供水管路水力計算 .......................................... 34 167。 空調(diào)風機盤管水系統(tǒng)供、回、凝水管 ................................................ 39 167。 機房布置原則 ............................................................................................ 41 167。 冷水機組的選擇 ............................................................................ 42 167。 定壓補水水箱選擇 ........................................................................ 44 167。從建筑結(jié)構(gòu)及其要求制定空調(diào)方案,要求能夠滿足使用的要求,即能夠滿足辦公舒適性。并能對以后的使用和費用支出做一定的預估。能夠有效的管理,一次性投資,后期使用方便,并且不占用建 筑的有效空間。從冷負荷計算,到室內(nèi)方案的選擇和設(shè)備的選型。從使用性到科學性再到經(jīng)濟性上