【正文】
s design, exterior design parameters in Beijing and Interior Design Parameters for Different types of room, I would like to load calculations, programmes have been identified, hydraulic calculation of air flow identification, equipment selection, and room layout work, etc. Court of First Instance ( in the courts, including the courts, small courts and criminal courts ) All on a one or two story, more number of people in the room, and dehumidifying ability required, and choose ceiling air conditioning units and one or two ancillary office and three to 12 storey office room small, relatively few staff, for the use of air water systems ( fan coil Air System ).Due to the building for the court building, different from ordinary writing plex, the Tribunal has a strict noise control, so when air conditioning System Design for various court room, takes into account not only meet the requirements of temperature and humidity of the room fort, but also to control the gas flow in the wind, preventing excessive speed caused the noise does not meet the requirements. The principles of design in the practicality and economy, to the court building in central air conditioning load and calculation of air flow system, various selection of equipment, hydraulic calculation of air ducts and pipes as well as the selection and arrangement of the engine room, fortable and healthy indoor environment can be designed as far as possible.Keyword: air conditioning design, the courts, fan coil目 錄1 工程簡(jiǎn)介 3 工程概況 3 設(shè)計(jì)基本資料 3 設(shè)計(jì)內(nèi)容 42 負(fù)荷計(jì)算 5 負(fù)荷計(jì)算的方法 5 屋頂和外墻的冷負(fù)荷 5 窗戶瞬時(shí)冷負(fù)荷和窗戶日射得熱冷負(fù)荷 5 照明、人體和設(shè)備散熱得熱冷負(fù) 6 濕負(fù)荷 6 負(fù)荷計(jì)算實(shí)例 63 空調(diào)方案的確定 14 空調(diào)系統(tǒng)的分類 14 按照空氣處理設(shè)備的集中程度情況分類 14 14 根據(jù)集中空調(diào)系統(tǒng)處理的空氣來(lái)源分類 14 空調(diào)系統(tǒng)的劃分 15 系統(tǒng)劃分的原因 15 系統(tǒng)化分的原則 15 空調(diào)制冷方案的確定 15 送風(fēng)方案方案的確定 164 系統(tǒng)風(fēng)量的確定 17 送風(fēng)量的確定 17 新風(fēng)量的確定 17 全空氣系統(tǒng)風(fēng)量的確定 18 風(fēng)機(jī)盤管加新風(fēng)系統(tǒng)風(fēng)量計(jì)算 185 空調(diào)設(shè)備的選型 20 空調(diào)機(jī)組選型 20 風(fēng)機(jī)盤管選型 20 新風(fēng)機(jī)組的選型 206 水力計(jì)算 21 管道的水力計(jì)算 21 風(fēng)管水力計(jì)算 23 風(fēng)管設(shè)計(jì) 23 風(fēng)管水力計(jì)算 237 制冷站方案的確定 25 制冷機(jī)組的選擇 25 冷凍水泵的選擇 25 冷凍水循環(huán)水量 25 冷凍水泵揚(yáng)程 25 冷凍水泵選型 26 冷卻水泵選型 26 確定冷卻水循環(huán)水量 26 確定冷卻水泵揚(yáng)程 26 冷卻水泵選型 27 冷卻塔的選擇 28 分集水器的選擇 28 熱交換器的選擇 28 補(bǔ)水、定壓設(shè)計(jì) 30 軟水器、補(bǔ)水泵選型設(shè)計(jì) 30 氣壓罐和補(bǔ)水箱設(shè)計(jì) 31 制冷機(jī)房布置 328 吸聲和降噪 349 排風(fēng)與通風(fēng)設(shè)計(jì) 3510 保溫與隔熱 3611 結(jié)論 37參考文獻(xiàn) 38翻譯部分 39。本設(shè)計(jì)本著實(shí)用性和經(jīng)濟(jì)性的原則,對(duì)這個(gè)法院建筑中央空調(diào)系統(tǒng)進(jìn)行了負(fù)荷及風(fēng)量的計(jì)算、各種設(shè)備的選型、風(fēng)管及水管的水力計(jì)算以及機(jī)房的選型及布置,盡量可以設(shè)計(jì)出舒適而健康的室內(nèi)環(huán)境。法庭(包括大法庭、中法庭、小法庭及刑事法庭)全部集中在一、二層,房間內(nèi)人員數(shù)量較多,所需除濕能力較強(qiáng),故選擇吊頂式空調(diào)機(jī)組,而一、二層附屬辦公室及三層至十二層辦公室房間較小,人員相對(duì)較少,適合采用空氣—水系統(tǒng)(風(fēng)機(jī)盤管加新風(fēng)系統(tǒng))。動(dòng)力》 中國(guó)計(jì)劃出版社 [7] 《公共建筑節(jié)能設(shè)計(jì)標(biāo)準(zhǔn)》中國(guó)建筑工業(yè)出版社 GB501892005 [8] 《建筑設(shè)計(jì)防火規(guī)范》 GB500162006[9] 《高層民用建筑設(shè)計(jì)防火規(guī)范》 GB5004595(2005年版)[10] 陸亞俊.《暖通空調(diào)》(第二版) .中國(guó)建筑工業(yè)出版社 [11] 暖通空調(diào)制圖標(biāo)準(zhǔn) GB/T501142001[12] 《05系列建筑標(biāo)準(zhǔn)設(shè)計(jì)圖集 采暖通風(fēng)專業(yè) 05N105N6》 DBJT04192005[13] 《空氣調(diào)節(jié)用制冷技術(shù)》(第三版)中國(guó)建筑工業(yè)出版社 2002年6月[14] 《采暖通風(fēng)與空氣調(diào)節(jié)設(shè)計(jì)規(guī)范》GB500192003 第 35 頁(yè) 第 3 頁(yè)摘 要本次設(shè)計(jì)的是北京市某法院建筑的中央空調(diào)系統(tǒng)設(shè)計(jì)。 第 34 頁(yè)參考文獻(xiàn)[1] 陸耀慶.《實(shí)用供熱空調(diào)設(shè)計(jì)手冊(cè)》(第二版).中國(guó)建筑工業(yè)出版社 [2] 江億.《溫濕度獨(dú)立控制空調(diào)系統(tǒng)》.中國(guó)建筑工業(yè)出版社[3] 李志生.《中央空調(diào)設(shè)計(jì)與審圖》.機(jī)械工業(yè)出版社 [4] 姜湘山,班福忱.《暖通空調(diào)設(shè)計(jì)要點(diǎn)》.機(jī)械工業(yè)出版社 [5] 荊有印,高月芬,鄭國(guó)忠.《暖通空調(diào)設(shè)計(jì)及系統(tǒng)分析》 中國(guó)電力出版社 [6] 王素卿等.《全國(guó)民有建筑工程設(shè)計(jì)技術(shù)措施在設(shè)計(jì)一層的大法庭(101房間)時(shí),由于大法庭為一二兩層相通的大空間房間,若只在二層頂棚進(jìn)行送風(fēng),人的活動(dòng)區(qū)域的制冷效果必定相當(dāng)差,舒適性不高,所以針對(duì)101大法庭房間,本設(shè)計(jì)選擇了兩臺(tái)吊頂式中央空調(diào)機(jī)組均設(shè)置在大法庭兩側(cè)走道的貼梁處,所對(duì)應(yīng)的風(fēng)管亦在走道內(nèi)貼梁,從主風(fēng)管伸出軟管伸進(jìn)房間內(nèi),再利用房間內(nèi)的百葉風(fēng)口側(cè)送至房間內(nèi),以提高室內(nèi)房間的舒適性。法院建筑中的主要房間,一二層主要是法庭(包括大法庭、中法庭、小法庭及各刑事法庭)和合議室,三層以上樓層主要就是辦公室。在空調(diào)房間內(nèi)的風(fēng)管如果太長(zhǎng),對(duì)室內(nèi)參數(shù)有不利影響時(shí),也應(yīng)保溫。4)當(dāng)設(shè)備或管道內(nèi)的氣體有凝結(jié)物時(shí),防止內(nèi)部出現(xiàn)凝結(jié)而堵塞,如排風(fēng)中含有苯蒸汽時(shí),則排風(fēng)管內(nèi)溫度過(guò)低時(shí)可能形成凝結(jié)物。2)防止設(shè)備或管道的表面溫度過(guò)高,而致人燙傷,或引起有燃燒爆炸危險(xiǎn)地氣味、粉塵起火爆炸等。3)加壓防煙 指用風(fēng)機(jī)把一定量的室外空氣送入一房間或通道內(nèi),使室外保持一定壓力或門洞內(nèi)有一定得流速,以避免煙氣侵入。為了防止火勢(shì)蔓延和煙氣傳播,各國(guó)的法規(guī)中對(duì)建筑內(nèi)部間隔作了明文規(guī)定,規(guī)定建筑中必須劃分防火分區(qū)。煙氣的控制實(shí)質(zhì)是控制煙氣的合理流動(dòng)。因此防火排煙在建筑設(shè)計(jì)中顯得尤為重要。建筑火災(zāi)煙氣是造成人員傷亡的主要原因。這樣可以使空氣直接排出室外。9 排風(fēng)與通風(fēng)設(shè)計(jì)衛(wèi)生間內(nèi)不設(shè)回風(fēng),衛(wèi)生間排風(fēng)換氣次數(shù)為10次/小時(shí),在衛(wèi)生間內(nèi)設(shè)置排風(fēng)扇,機(jī)械排風(fēng),以形成負(fù)壓。另外,選擇機(jī)房位置時(shí)應(yīng)盡量不靠近空調(diào)房間。除了采用隔振措施減少對(duì)外傳播噪聲外還必須采取其他措施降低機(jī)房?jī)?nèi)噪聲和隔斷向外傳播的途徑。通常的辦法有:管道與支架、吊卡間墊軟材料,采用隔振吊架。風(fēng)機(jī)進(jìn)出口與風(fēng)管間