【正文】
s development. But in the construction energy consumption, uses in passing air conditioning the energy consumption to occupy the construction energy consumption warmly 30%50%, also is rising year by year. Increases unceasingly along with the average per person floor space, passes the airconditioning system warmly the widespread application, will use in passing the airconditioning system the energy consumption further to increase warmly. This will be able to enable the source supply and demand contradictory further intensification inevitably.On the other hand, existing basically passed the energy which the airconditioning system used is warmly the high grade nonrenewable energy, in which electrical energy has accounted for the absolute proportion. To these energy massive uses, causes the earth resource to be day by day deficient, simultaneously also brings the serious environment question, like in our country39。 Economizing energy techniques。 value and the support, then is realizes the large scale energy conservation, produces the remarkable environment and the social efficiency, the impetus economy development guarantee. Key word: HVAC。經(jīng)過對保溫材料經(jīng)濟與熱工性能分析、比較水管用泡沫橡塑作為保溫材料;風管用離心玻璃棉較經(jīng)濟,性能也能達到要求。PVC/NBR橡塑發(fā)泡保溫板、管殼(難燃B1級)~。: 保溫材料特性保溫材料特性外覆鋁箔的離心玻璃棉管殼~。 保溫材料的選擇計算 保溫材料的選擇空調冷熱水管、風管、凝結水管和屋面冷卻水管均需保溫。H =+=根據(jù)《中央空調設計實訓教程》[1]附錄,選用二臺IS5032125型水泵, 3/h,轉速為1450r/min。1) ,而補水量為制冷機配套循環(huán)水泵流量的1%到3%。根據(jù)《中央空調設計實訓教程》[1]附錄,選用三臺IS125100200型水泵,其流量為100m 3/h,轉速為1450r/min。根據(jù)水泵工作時,取流量儲備系數(shù) =。 冷卻水泵的選擇根據(jù)選型原則,選擇三臺冷凍水泵(兩用一備)。如果水泵從低位水箱吸水,吸水管上還應該安裝真空表。3.水泵的吸入管和壓出管上應分別設進口閥和出口閥;目的是便于水泵不運行能不排空系統(tǒng)內的存水而進行檢修。 冷凍水泵配管布置進行水泵的配管布置時,應注意以下幾點:1.安裝軟性接管:在連接水泵的吸入管和壓出管上安裝軟性接管,有利于降低和減弱水泵的噪聲和振動的傳遞。水泵設計揚程為H ==。環(huán)路中各種管件的水壓降和沿程壓降之和按估算法計算:水系統(tǒng)為異程式。冷水機組蒸發(fā)器的水壓降=83KPa= mH20。 Hmax (76)式中:H——水泵揚程,m; Hmax——水泵所承擔的最不利環(huán)路的水壓降,mH2O; ——揚程儲備系數(shù)取=。則單臺水泵設計流量V == L/s= m 3/h。1)水泵流量的確定單臺冷水機組的額定水流量為60 m 3/h , L/s。[8] 冷凍水泵的選型和計算 冷凍水泵的選型和計算根據(jù)選型原則,選擇三臺冷凍水泵(兩用一備)。管長由所需連接的管的接頭個數(shù)、管徑及間距確定,兩相鄰管接頭中心線間距為兩管外徑+1200mm,兩邊管接頭中心線距集管斷面宜為管外徑+60mm。供回水集管上的各管路均應設置調節(jié)閥和壓力表,底部應設置排污閥或排污管(一般選用DN40)。℃);不同機型冷凝器單位產冷量的散熱量,可按下式估算:對于吸收式制冷機組: (74)式中:——冷水機組的制冷量,kW;故=3600單臺冷卻塔冷卻水量W′=W/2= m3/h故選擇2臺河南開通廠家生產的BNGD100型圓形逆流式中溫低噪聲冷卻塔,中溫系列工況,進塔水溫為40℃,出塔水溫為32℃,水溫差為8℃,主要技術參數(shù)見下:型號冷卻水量(m3/h)風量(m3/h)風機直徑(mm)電機功率(kw)進水壓力(104Pa)BNGD1001006500020003 集水器和分水器的選擇供水集管又稱分水器(或分水缸),回水集管又稱集水器(或回水缸),它們都是一段水平安裝的大管徑鋼管。WT高頻電子水垢處理器利用高頻電磁場作用流經(jīng)處理器的水,可以防止硬垢生成,有效地殺滅水中的藻類,菌類等,有效地抑制水中微生物的繁殖。 水處理裝置的選擇水處理裝置中以安裝軟化水設備最好,但價格高,占地面積大,電子水處理裝置是近年來應用較好的一種水處理裝置。《工業(yè)企業(yè)噪聲控制規(guī)范》(GBJ8785)的規(guī)定。因此,濕式冷卻塔需要有供給的水源。但是水因蒸發(fā)而造成損耗;蒸發(fā)又使循環(huán)的冷卻水含鹽度增加,為了穩(wěn)定水質,必須排掉一部分含鹽度較高的水;風吹也會造成水的飄散損失。用這種方式冷卻的稱為濕式冷卻塔。冷卻塔的作用是將攜帶熱量的冷卻水在塔內于空氣進行換熱,使熱量傳輸給空氣大氣?!? ——冷凍水的出口溫度,7℃;——為冷凍水的入口溫度,12℃; 冷卻塔的選擇 冷卻塔的冷卻原理制冷系統(tǒng)產生的熱量,必須導走并耗散掉。本設計選用ZXLR系列直燃型溴化鋰吸收式冷熱水機組2臺,其型號為ZXLR35,單機制冷能力為349 KW。進行技術經(jīng)濟比較后,宜優(yōu)先采用能量調節(jié)自動化程度較高的冷水機組,本設計選用直燃型溴化鋰吸收式冷熱水機組。制冷機選擇,應考慮其對環(huán)境的影響:1.噪聲與振動要控制在環(huán)境條件允許指標之內。選擇冷水機組時,應根據(jù)建筑物用途、冷水溫度、以及電源、水源和熱源等情況,從初投資和運行費用進行技術經(jīng)濟比較確定。冷水機組按驅動的動力可分為兩類,一類是電力驅動的冷水機組,包括活塞式冷水機組, 螺桿式冷水機組和離心式冷水機組;另一類式熱力驅動的冷水機組,又稱吸收式冷水機組,分為蒸汽或熱水式吸收式冷水機組和直燃式吸收式冷水機組。綜合以上因素,本設計選用水冷機組。 冷熱源方案比較風冷制機組與水冷制冷機組的技術經(jīng)濟比較:風冷制冷機組適用于所處地域水源緊張的中、小系統(tǒng);對年運行時數(shù)越長的制冷系統(tǒng)采用風冷制冷機組越有利;風冷制冷機組的年度綜合費用低于水冷系統(tǒng),但水冷系統(tǒng)若管理得法,補水量控制在3%以下,則風冷制冷機組較水冷制冷機組所增加的初投資很難回收??照{系統(tǒng)冷熱源設計的合理與否會直接影響空調系統(tǒng)是否能正常經(jīng)濟運行。 3)風機盤管的冷凝水管管徑,應根據(jù)冷凝水流量和冷凝水管的最小坡度確定,為計算方便,可按冷負荷確定冷凝水的管徑,~。其它水平支干管,沿水流方向,且不允許有積水部位;2)冷凝水管道宜采用聚乙烯塑料管或鍍鋅鋼管,不宜采用焊接鋼管。其他計算結果見附表。=178。以一層101為例,水力計算圖如下:,流量為=(127)=,根據(jù)流量與比摩阻查水管路計算圖得出管徑為DN20。并將總局部阻力系數(shù)填入水管水力計算表。3)根據(jù)各管段的管徑和流量,計算各管段的實際流速,并查水管路計算圖,求得各管路的實際比摩阻。現(xiàn)以一層供(回)水管為例說明基本計算步驟:1)選擇最不利管路123456789101112。為保證資用壓力符合要求,現(xiàn)以各房間的夏季最大冷負荷為準計算流量,根據(jù)公式[7] (61)其中:——計算流量,kg/h ;——房間的冷負荷 W;th——水系統(tǒng)回水溫度(取12℃);tg——水系統(tǒng)供水溫度,(取7℃)。“為了減小風機盤管水系統(tǒng)的管徑,管路設計時通常選用較大的比摩,一般取120~400Pa/m,小管徑取大些的數(shù)值,大管徑取小些的數(shù)值。 水管部分 以推薦流速法進行空調水系統(tǒng)水力計算:。4摩擦阻力: Pa:該管段的局部阻力系數(shù):∑ξ=則局部阻力為 Pa總阻力為: Pa同理計算其他各管段的局部阻力及沿程阻力和局部阻力,進而求得總阻力。管段1:假定流速V=,根Q=,F(xiàn)=(3600)=,查文獻[8],選擇規(guī)格為200㎜200㎜,則實際流速V=,根據(jù)實際流速和流量,查文獻[8],比摩阻為Rm=。其主要目的是,確定各管段的管經(jīng)(或斷面尺寸)和阻力,保證系統(tǒng)內達到要求的風量分配,最后確定風機的型號和動力消耗,采用假定流速法進行水力計算,為使風量均勻送排風,可用假定流速法來演繹靜壓復得法,即利用動壓差克服阻力,達到均勻送排風。衛(wèi)生間排風由各換氣扇的排風管集中到排風豎井, 通過排風豎井將排氣扇排出的氣體排至室外。1℃的要求。=夏季工況送風,= m/s m/s的要求。+178。)189。4.計算室內平均風速=(L178。]=,,則散流器的有效流通面積為F=()178??臻g長、寬、高分別為ABH=。本工程一層至四層采用風機盤管+獨立新風的空調系統(tǒng),采用高靜壓型臥式暗裝機組,為節(jié)省投資,減少噪聲源,采用一機多口的送風方式,即通過機組出口處附加的多接頭靜壓箱,經(jīng)軟管與兩到三個出風口相連接的送風方式,暗裝在吊頂內,機組出口接送風管,風管底部設有兩到三個圓形散流器,新風采用散流器平送。 送、回風方式及風口形式空調房間常采用氣流組織形式的送風方式,按其特點主要可分為側送、孔板送風、散流器送風、條縫送風和噴口送風等。氣流組織設計的任務是合理地組織室內空氣的流動,使室內工作區(qū)空氣的溫度﹑相對濕度﹑速度和潔凈度能更好地滿足人們的舒適性要求。 新風機組選擇計算每層設置兩臺新風機組,以一層為例:右環(huán)路新風機組1:新風量 Mo=新風冷負荷 Qc=修正后的冷負荷 Q== 供冷工況干球溫度 34℃濕球溫度 28℃冷水進水溫度 7℃選用吊頂式新風機組LWHA033,新風機組性能參數(shù)如下表:風量 m3/h冷量kw水量L/s水阻力KPa電機轉速r/min離心風機數(shù)量外形尺寸LBH mm33001430113441223475同理可以對其他各層選擇新風機組,選擇結果見下表。2.確定M點:(44)式中:Q為空調房間總負荷,可得 =()/= kJ/kg 3.FP供冷量: 全冷量: =()= kW4.風機盤管的選用:【5】 1 選用FP8型風機盤管機組1臺,高檔風量880;機組的冷量是5850w,能滿足要求。), m178。如果計算所得的新風量不足系統(tǒng)風量的10%,則取系統(tǒng)送風量的10%。新風量通常應滿足以下三個要求:【4】,保證人群對空氣品質的要求;;。Kg/s,則=[(18)]/[(18+2500) ]= g/kg=18+(2500+18)=()= Kg/s= 最小新風量確定的原則:一個完善的空調系統(tǒng),除了滿足對環(huán)境的溫、濕度控制以外,還必須給環(huán)境提供足夠的新風。以101辦公室為例,=26℃,送風溫差為8℃,則=18℃,室內相對濕度=60%,查焓濕圖得出=,=, Q= ,W=10175。① (41)② (42)③ (43)上式中的已知參數(shù)為Q、W、,未知參數(shù)為、。所以本設計選擇新風處理到室內狀態(tài)的等焓線,不承擔室內冷負荷方案。 風機盤管加新風系統(tǒng)的空氣處理風機盤管加新風系統(tǒng)的空氣處理方式有:1.新風處理到室內狀態(tài)的等焓線,不承擔室內冷負荷;2.新風處理到室內狀態(tài)的等含濕量線,新風機組承擔部分室內冷負荷;3.新風機組不僅承擔新風冷負荷,還承擔部分室內顯熱冷負荷和全部潛熱冷負荷,風機盤管僅承擔一部分室內顯熱冷負荷,可實現(xiàn)等濕冷卻,可改善室內衛(wèi)生和防止水患;4.新風處理到室內狀態(tài)的等溫線,風機盤管承擔的負荷很大,特別是濕負荷很大,造成衛(wèi)生問題和水患;5.新風處理到室內狀態(tài)的等焓線,并與室內狀態(tài)點直接混合進入風機盤管處理。以101辦公室為例,=5109= kg/h,其他房間見附表5。p);26℃時,極輕勞動成年男子的小時散熱量為109 g/(h以101房間為例,=()= kW其他房間見附表5。人體散熱冷負荷時間