【正文】
but the “rational” decision making process does require a longer processing time. In an emergency situation where decisions need to be made instantly, an individual may opt for a faster method by simply following instincts or experiences, resulting at times to what is referred to as irrational behaviors (Le Bon, 1960). On the other hand, altruistic and prosocial behaviors are monly observed in emergencies (Bryan,2003。 (3) weigh each consequence against preferences。 and (3) carry out the routines.? Bounded rationality. The idea of bounded rationality has been integrated into many conventional social theories and e to dominate most theories of individual decision making (March, 1994). Rational decisionmaking assumes decisions are based on evaluation of alternatives in terms of their consequences for preferences. The process involves four basic steps: (1) search for possible options。 Sime, 1986), such as the familiarity of the surroundings, safety procedures, and fire drills. However, “using prior evacuation experience to guide future evacuation decisions, may or may not produce better outes” (Averill et al., 2005, ). One observed phenomenon is that most people tend to exit a building following the route with which they are mostfamiliar and ignore alternate routes. Decisionmaking in terms of following experience is usually straightforward and quick. The process typically follows three basic steps: (1) recognize a situation that is the same as or similar to an experience in the past。 Society of Fire Protection Engineers, 2002。[6]《電氣消防》[7]《給水排水設(shè)計(jì)手冊(cè)》[8]《自動(dòng)噴水滅火系統(tǒng)設(shè)計(jì)手冊(cè)》[9]《汽車庫(kù)、修車庫(kù)、停車場(chǎng)設(shè)計(jì)防火規(guī)范 GB 50067-97》[10]《建筑設(shè)計(jì)防火規(guī)范GB 50016-2006》[11]《GST通用火災(zāi)自動(dòng)報(bào)警及消防控制系統(tǒng)應(yīng)用設(shè)計(jì)說(shuō)明書》[12]《高層建筑給排水設(shè)計(jì)手冊(cè)》[13]《自動(dòng)噴水滅火系統(tǒng)設(shè)計(jì)手冊(cè)》[14]《給排水設(shè)計(jì)手冊(cè)》[15]《民用建筑電氣設(shè)計(jì)規(guī)范》[16]網(wǎng)絡(luò)、企業(yè)內(nèi)部資料等相關(guān)參考資料。中國(guó)建筑工業(yè)出版社,1998,第一版。中國(guó)建筑工業(yè)出版社,2009,第二版。化學(xué)工業(yè)出版社,2006,第一版。中國(guó)建筑工業(yè)出版社,2000,第一版。同時(shí),在論文寫作過(guò)程中,我還參考了有關(guān)的書籍和論文,在這里一并向有關(guān)的作者表示謝意。在此向老師表示深深的感謝和崇高的敬意!在臨近畢業(yè)之際,我還要借此機(jī)會(huì)向在這4年中給予我諸多教誨和幫助的各位老師表示由衷的謝意,感謝他們4年來(lái)的辛勤栽培。消火栓系統(tǒng)和噴淋系統(tǒng)分別有兩根出水管接入水池,水池旁側(cè)設(shè)有進(jìn)水管與市政管網(wǎng)接通為系統(tǒng)供水。 消防水池的有效容量可按下式計(jì)算: 式中 V消防水池的有效容量,; n 需要同時(shí)開啟的滅火系統(tǒng)種類數(shù); 所負(fù)擔(dān)的某類滅火系統(tǒng)用水量,L/s; 該滅火系統(tǒng)相應(yīng)的火災(zāi)延續(xù)時(shí)間,h; 火災(zāi)延續(xù)時(shí)間內(nèi)外網(wǎng)可靠連續(xù)補(bǔ)充水量,L/s; 中的最大者,h。當(dāng)室外給水管網(wǎng)能滿足室外消防用水量時(shí),消防水池的有效容積應(yīng)滿足火災(zāi)在延續(xù)時(shí)間內(nèi)的室內(nèi)消防用水量的需求,當(dāng)室外給水管網(wǎng)不能保證消防用水量時(shí),消防水池的有效容積應(yīng)該滿足火災(zāi)延續(xù)時(shí)間內(nèi)室內(nèi)與室外消防用水量不足部分之和的要求。管道采用DN150和DN100兩種管道。 選定噴淋泵、噴淋給水系統(tǒng)管道的型號(hào) 消防水泵的揚(yáng)程為: Hb=()+2++10= mH2O.作用面積內(nèi)所需總流量為:Q=按照自噴系統(tǒng)的計(jì)算結(jié)果,選定水泵型號(hào)為:型號(hào)為IS125100250,總揚(yáng)程為100,功率為75Kw 。給水管道選擇DN150的管道。5消防泵房與消防水池的主要設(shè)計(jì)內(nèi)容 根據(jù)室內(nèi)消火栓給水系統(tǒng)的設(shè)計(jì)計(jì)算知道, 選定消火栓泵、消火栓給水管道的型號(hào) 根據(jù)室內(nèi)消火栓給水系統(tǒng)的水力計(jì)算,選擇消火栓泵的型號(hào)為XQBWⅡ14540型消防泵兩臺(tái),一用一備,設(shè)于地下室泵房。若公用水池時(shí),消防進(jìn)水口必須在其他進(jìn)水口之下,但不得超過(guò)6m。消防水池是人工建造的儲(chǔ)存消防用水的構(gòu)筑物,是天然水源或市政給水管網(wǎng)的一種重要補(bǔ)充手段。附設(shè)在單層、多層或高層建筑內(nèi)的泵房,要有較好的防火分隔。4消防泵房與消防水池的介紹消防水泵房是消火栓、自動(dòng)噴水滅火系統(tǒng)以及其他滅火系統(tǒng)的“心臟”,在火災(zāi)延續(xù)時(shí)間內(nèi),人們必須堅(jiān)持工作,不能受到火災(zāi)威脅。(7)最大接線長(zhǎng)度≤1000m(8)控制器外形尺寸:500mm700mm170mm。 (5)電源:主電:AC220V,備電:DC24V 14Ah密封鉛電池作備電(6)功耗:監(jiān)控功耗≤55W,最大功耗≤70W 相對(duì)濕度≤95%,不結(jié)露規(guī)格:(1)液晶屏規(guī)格:320240圖形點(diǎn)陣,可顯示12行漢字信息(2)控制器容量: ,最大容量為484個(gè)地址編碼點(diǎn) ;聯(lián)網(wǎng)時(shí)最多可接32臺(tái)其他類型控制器 (3)線制:控制器與探測(cè)器間采用無(wú)極性信號(hào)二總線連接(4)使用環(huán)境:溫度:0℃~+40℃ 相對(duì)濕度:≤95% (2)監(jiān)視電流≤ (3)動(dòng)作電流≤ (4)線制:與控制器無(wú)極性信號(hào)二總線連接(5)無(wú)源輸出觸點(diǎn)容量:DC60V/100mA(6)使用環(huán)境:溫度:10℃~50℃規(guī)格: 手動(dòng)報(bào)警按鈕:JSAP8401手動(dòng)火災(zāi)報(bào)警按鈕安裝在公共場(chǎng)所,當(dāng)人工確認(rèn)火災(zāi)發(fā)生后按下按鈕上的有機(jī)玻璃片,可向控制器發(fā)出火災(zāi)報(bào)警信號(hào),控制器接收到報(bào)警信號(hào)后,顯示出報(bào)警按鈕的編號(hào)或位置并發(fā)出報(bào)警音響,手動(dòng)火災(zāi)報(bào)警按鈕和前面介紹的各類編碼探測(cè)器一樣,可直接接到控制器總線上。具體設(shè)計(jì)參數(shù)應(yīng)以《火災(zāi)自動(dòng)報(bào)警系統(tǒng)設(shè)計(jì)規(guī)范》(GB50116)為準(zhǔn)。本探測(cè)器具有以下特點(diǎn):(1) 結(jié)構(gòu)新穎、外形美觀,性能穩(wěn)定可靠;(2) 采用帶A/D轉(zhuǎn)換的單片機(jī),實(shí)時(shí)采樣處理數(shù)據(jù)、并能保存14個(gè)歷史數(shù)據(jù),曲線顯示跟蹤現(xiàn)場(chǎng)情況;(3) 地址編碼由電子編碼器直接寫入,工程調(diào)試簡(jiǎn)便可靠。該探測(cè)器保護(hù)面積滿足建筑要求,其它各項(xiàng)性能也均能滿足探測(cè)要求,故選擇該種探測(cè)器。 直徑:100mm,高:56mm保護(hù)面積一個(gè)探測(cè)器的保護(hù)面積,對(duì)一般保護(hù)場(chǎng)所而言為80㎡。 相對(duì)濕度≤95%,不結(jié)露(6)編碼方式:十進(jìn)制電子編碼(7)外殼防護(hù)等級(jí):IP23(8)外形尺寸:規(guī)格:(1)工作電壓:總線24V(2)監(jiān)視電流≤ (3)報(bào)警電流≤(4)報(bào)警確認(rèn)燈:紅色,巡檢時(shí)閃爍,報(bào)警時(shí)常亮(5)使用環(huán)境:溫度:10℃~+55℃本設(shè)計(jì)建筑物等級(jí)和保護(hù)對(duì)象都比較重要,故選擇第二種報(bào)警方式。另一種方式是:區(qū)域或集中報(bào)警器方式都應(yīng)報(bào)出整個(gè)火災(zāi)自動(dòng)報(bào)警系統(tǒng)中的任何一個(gè)區(qū)位號(hào)或部位號(hào)。一般可分為兩種方式報(bào)警?;馂?zāi)自動(dòng)報(bào)警方式,一般應(yīng)根據(jù)各類建筑物性質(zhì)和防火管理方式的不同來(lái)確定。(2)在環(huán)境噪聲大于60dB的場(chǎng)所設(shè)置的揚(yáng)聲器,在其播放范圍內(nèi)最遠(yuǎn)點(diǎn)的播放聲壓級(jí)應(yīng)高于背景噪聲15dB?;馂?zāi)應(yīng)急廣播揚(yáng)聲器的設(shè)置,應(yīng)符合下列要求:(1)民用建筑內(nèi)揚(yáng)聲器應(yīng)設(shè)置在走道和大廳等公共場(chǎng)所。(2)具有多個(gè)報(bào)警區(qū)域的保護(hù)對(duì)象,宜選用帶有語(yǔ)音提示的火災(zāi)聲警報(bào)器,語(yǔ)音應(yīng)同步?!?,且有明顯的標(biāo)志。手動(dòng)火災(zāi)報(bào)警按鈕及消火栓按鈕設(shè)置在樓梯口處、走廊等公共場(chǎng)所的明顯部位,從一個(gè)防火分區(qū)內(nèi)的任何位置到最鄰近的一個(gè)手動(dòng)火災(zāi)報(bào)警按鈕的距離不大于30m。(7)集中火災(zāi)報(bào)警控制器或火災(zāi)報(bào)警控制器安裝在墻上時(shí)。(5)設(shè)備面盤后的維修距離不宜小于1m。(3)設(shè)備面盤前的操作距離:;雙列布置時(shí)不應(yīng)小于2m。集中報(bào)警控制器的設(shè)置,應(yīng)符合下列要求:(1)系統(tǒng)中應(yīng)設(shè)置一臺(tái)集中火災(zāi)報(bào)警控制器和兩臺(tái)及以上區(qū)域火災(zāi)報(bào)警控制器,或設(shè)置一臺(tái)火災(zāi)報(bào)警控制器和兩臺(tái)及以上區(qū)域顯示器。(1)為計(jì)算方便,將右樓梯右邊區(qū)域分為一個(gè)探測(cè)區(qū)域,由于是地下車庫(kù),采用感溫探測(cè)器,具體布置如下:1)S=**=30 m2 N===N取10只2)確定探測(cè)器的安裝間距a、b a=,b= 3)驗(yàn)算: ab=KA=*30=27m2 r=== m該區(qū)域需要布置10只感煙探測(cè)器,且布置符合要求(2)右樓梯間下作為一個(gè)探測(cè)區(qū)域,采用感溫探測(cè)器,具體布置如下:1)S=*=67m230 m2 N===N取4只2)確定探測(cè)器的安裝間距a、b a=,b= 3)驗(yàn)算: ab=17KA=*30=27m2 r===3 m該區(qū)域需要布置4只感煙探測(cè)器,且布置符合要求.(3)兩樓梯間區(qū)域?yàn)橐粋€(gè)探測(cè)區(qū)域,采用感溫探測(cè)器,具體布置如下:1)S=18*=30 m2 N===為布置方便N取12只2)確定探測(cè)器的安裝間距a、b a==,b== 3)驗(yàn)算: ab=KA=*30=27m2 r=== m該區(qū)域需要布置12只感煙探測(cè)器,且布置符合要求.(4)左樓梯間下的區(qū)域?yàn)橐粋€(gè)探測(cè)區(qū)域,采用感溫探測(cè)器,具體布置如下:1)S=*=30 m2 N===N取4只2)確定探測(cè)器的安裝間距a、b a==,b== 3)驗(yàn)算: ab=KA=*30=27m2 r=== m該區(qū)域需要布置4只感煙探測(cè)器,且布置符合要求. 區(qū)域報(bào)警系統(tǒng)火災(zāi)報(bào)警控制器的設(shè)置,應(yīng)符合下列要求:(1)火災(zāi)報(bào)警控制器或火災(zāi)報(bào)警控制器設(shè)置在有人值班的房間或場(chǎng)所。(13)電梯前空間采用感煙探測(cè)器,(11)。(11)右樓梯間采用感煙探測(cè)器,(9)。(5)中間2個(gè)豪華套間的客廳采用感煙探測(cè)器,具體布置如下:1)S=*=80 m2 N===N取1只2)確定探測(cè)器的安裝間距a、b a=,b= 3)驗(yàn)算: ab=KA=*80=72m2 r===該區(qū)域需要布置1只感煙探測(cè)器,且布置符合要求(6)中間豪華套間的主副臥室采用感煙探測(cè)器,具體布置如下:1)S=*=80 m2 N===N取1只2)確定探測(cè)器的安裝間距a、b a=,b= 3)驗(yàn)算: ab=KA=*80=72m2 r===該區(qū)域需要布置1只感煙探測(cè)器,且布置符合要求(7)普通套間的客廳采用感煙探測(cè)器,具體布置如下:1)S=*=80 m2 N===N取1只2)確定探測(cè)器的安裝間距a、b a=,b= 3)驗(yàn)算: ab=KA=*80=72m2 r===該區(qū)域需要布置1只感煙探測(cè)器,且布置符合要求(8)普通套間的臥室采用感煙探測(cè)器,具體布置如下:1)S=*=80 m2 N===N取1只2)確定探測(cè)器的安裝間距a、b a=,b= 3)驗(yàn)算: ab=KA=*80=72m2 r===該區(qū)域需要布置1只感煙探測(cè)器,且布置符合要求(9)服務(wù)員室采用感煙探測(cè)器,(7)。(2)豪華